FM36YX Device Family Parameter list

From Wiki Knowledge Base | Teltonika GPS
Main Page > EOL Products > FM3612 > FM3612 Manual > FM36YX Device Family Parameter list

Parameters value types

S8 – Signed Char S8[n] – String of n Char U8 – Unsigned Char U16 – Unsigned Short S32 – Signed Integer U32 – Unsigned Integer U64 – Unsigned Long Long Integer

System parameters

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1000 U8 0 0 2 0 – Disabled Sleep Settings
1 – GPS Sleep
2 – Deep Sleep
200 U8 1 1 3000 - Sleep Timeout
1001 U8 0 0 1 0 - 10V Analog Input value range
1 – 30V
1002 U8 1 0 3 0 - ignition Stop Detection Source
1 - Msensor
2 - GPS
3 - ignition + Msensor
1003 U8 0 0 1 0 - Disabled Static Navigation
1 – Enabled
1004 0 0 2 0 – Power voltage Ignition Source
1 – Digital input 1
2 – Msensor
1005 30000 mV 13000 mV 30000 mV High Voltage Level
1006 13000 mV 0 30000 mV Low Voltage Level
1008 0 0 1 0 - Manual Ignition Detection
1 – Automatic
1009 U8 10 0 65535 Ignition Detection Timeout
1007 U8 60 0 65535 GNSS FIX Timeout for Time Synchronization via NTP
201 U8 0 0 1 0 - Disabled Saving/Sending without time synchronization
1 – Enabled
202 U8 0 0 2 0 – GNSS (all available) Satellite System
1 – GPS
2 – GLONASS

Records parameters

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1010 Uint8 default 0 1 0 – arranging data starting from newest Sorting
1 – arranging data starting from oldest
1011 Uint8 60 0 259200 Seconds Active Data Link Timeout
1012 Uint8 300 1 300 Seconds Server Response Timeout

GSM parameters

Data aquisition parameters

Features parameters

I/O parameters

LV-CAN Features

SMS EVENT CONFIGURATION