From Teltonika Telematics Wiki
Main Page > EOL Products > FM3612 > FM3612 Manual > FM36YX Device Family Parameter list
Parameters value types
S8 – Signed Char
S8[n] – String of n Char
U8 – Unsigned Char
U16 – Unsigned Short
S32 – Signed Integer
U32 – Unsigned Integer
U64 – Unsigned Long Long Integer
System parameters
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| 1000
|
U8
|
0
|
0
|
2
|
0 – Disabled
|
Sleep Settings
|
| 1 – GPS Sleep
|
| 2 – Deep Sleep
|
| 200
|
U8
|
1
|
1
|
3000
|
-
|
Sleep Timeout
|
| 1001
|
U8
|
0
|
0
|
1
|
0 - 10V
|
Analog Input value range
|
| 1 – 30V
|
| 1002
|
U8
|
1
|
0
|
3
|
0 - ignition
|
Stop Detection Source
|
| 1 - Msensor
|
| 2 - GPS
|
| 3 - ignition + Msensor
|
| 1003
|
U8
|
0
|
0
|
1
|
0 - Disabled
|
Static Navigation
|
| 1 – Enabled
|
| 1004
|
|
0
|
0
|
2
|
0 – Power voltage
|
Ignition Source
|
| 1 – Digital input 1
|
| 2 – Msensor
|
| 1005
|
|
30000 mV
|
13000 mV
|
30000 mV
|
|
High Voltage Level
|
| 1006
|
|
13000 mV
|
0
|
30000 mV
|
|
Low Voltage Level
|
| 1008
|
|
0
|
0
|
1
|
0 - Manual
|
Ignition Detection
|
| 1 – Automatic
|
| 1009
|
U8
|
10
|
0
|
65535
|
|
Ignition Detection Timeout
|
| 1007
|
U8
|
60
|
0
|
65535
|
|
GNSS FIX Timeout for Time Synchronization via NTP
|
| 201
|
U8
|
0
|
0
|
1
|
0 - Disabled
|
Saving/Sending without time synchronization
|
| 1 – Enabled
|
| 202
|
U8
|
0
|
0
|
2
|
0 – GNSS (all available)
|
Satellite System
|
| 1 – GPS
|
| 2 – GLONASS
|
Records parameters
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| 1010
|
Uint8
|
default
|
0
|
1
|
0 – arranging data starting from newest
|
Sorting
|
| 1 – arranging data starting from oldest
|
| 1011
|
Uint8
|
60
|
0
|
259200
|
Seconds
|
Active Data Link Timeout
|
| 1012
|
Uint8
|
300
|
1
|
300
|
Seconds
|
Server Response Timeout
|
GSM parameters
GPRS
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| 1240
|
S8
|
1
|
0
|
1
|
0 – GPRS is not allowed
|
GPRS content activation
|
| 1 – GPRS is allowed
|
| 1242
|
S8[32]
|
""
|
Empty
|
32 char string
|
string
|
APN Name
|
| 1243
|
S8[30]
|
""
|
Empty
|
30 char string
|
string
|
APN username
|
| 1244
|
S8[30]
|
""
|
Empty
|
30 char string
|
string
|
APN Password
|
| 1245
|
S8[16]
|
""
|
Empty
|
31 char string
|
string
|
Domain
|
| 1246
|
S8[16]
|
0
|
Empty
|
65535
|
number
|
Target Server Port
|
| 1247
|
U8
|
0
|
0
|
1
|
0 – TCP
|
Protocol
|
| 1 – UDP
|
| 1248
|
U8
|
0
|
0
|
1
|
0 – work with all networks
|
Network Type
|
| 1 – work with 2G network
|
| 2 – work with 3G network
|
| 3 – work with 4G network
|
SMS
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| ID
|
Uint8
|
default
|
min
|
max
|
0 – value = 0
|
Name
|
| 1 – value = 1
|
| ID
|
Uint8
|
default
|
min
|
max
|
Value
|
Name
|
| 1252
|
S8[5]
|
""
|
Empty
|
5 char string
|
string
|
SMS Login
|
| 1253
|
S8[5]
|
""
|
Empty
|
5 char string
|
string
|
SMS Password
|
| 1254
|
U8
|
0
|
-720
|
+840
|
minutes
|
SMS Time Zone
|
| 1250
|
U8
|
0
|
0
|
1
|
0 – SMS use is not allowed
|
SMS data sending settings
|
| 1 – SMS use is allowed
|
| 1273
|
For detail info
|
SMS Data send week time schedule
|
| 1260-1269
|
S8[17]
|
""
|
0 digit
|
16 digit
|
string
|
Authorized phone numbers
|
| 5000-5009
|
S8[17]
|
""
|
0 digit
|
16 digit
|
string
|
SMS Event PreDefined Numbers
|
Operator list
| Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
| Min
|
Max
|
| 1271
|
For detailed info
|
Operator list
|
Data aquisition parameters
Features parameters
I/O parameters
LV-CAN Features
SMS EVENT CONFIGURATION