!Not finished
System parameters
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
x000 | U8 | 0 | 0 | 3 | 0 – Disabled | Movement source |
1 – Enable | ||||||
2 – Deep Sleep | ||||||
3 – Online Deep Sleep | ||||||
x001 | U8 | 1 | 0 | 9000 | Minutes | Sleep timeout |
x900 | U8 | 0 | 0 | 5 | 0 - Power voltage | Ignition source |
1 - DIN 1 | ||||||
2 - DIN 2 | ||||||
3 - DIN 3 | ||||||
4 - DIN 4 | ||||||
5 - Movement | ||||||
x901 | U16 | 30000 | 0 | 30000 | Volts | High Voltage Level (for Ignition) |
x902 | U16 | 13000 | 0 | 30000 | Volts | Low Voltage Level (for Ignition) |