From Wiki Knowledge Base | Teltonika GPS
!Not finished
System parameters
Parameter
ID
Parameter value
Value type
MIN
MAX
Default
Recommended
Sleep Mode
x000
0
3
0
-
U8
0
Disable
1
Enable
2
Deep sleep
3
Online deep sleep
Sleep Timeout
x001
0
9000
1
-
U16
Ignition source
x900
0
5
0
-
U8
0
Power voltage
1
DIN 1
2
DIN 2
3
DIN 3
4
DIN 4
5
Movement
High Voltage Level(for Ignition)
x901
0
30000
0
-
U16
Low Voltage Level (for Ignition)
x902
0
30000
0
-
U16
GPRS data sending settings
Parameter
ID
Parameter value
Value type
MIN
MAX
Default
Recommended
Server 1
GPRS Context Activation
x240
0 (Disable)
1 (Enable)
0
-
S8
Protocol
0 (TCP)
1 (UDP)
0
-
U8
Server Response Timeout
5
300
5
-
U16
Domain
Empty
56 char
Empty
-
-
Target Server Port
0
65535
0
-
U16
Configuring format:
<Enable>,<IP>,<port>,<protocol>,<Server Reponse Tmo>
Server 2
GPRS Context Activation
x242
0 (Disable)
1 (Enable)
0
-
S8
Protocol
0 (TCP)
1 (UDP)
0
-
U8
Domain
Empty
56 char
Empty
-
-
Target Server Port
0
65535
0
-
U16
Configuring format:
<Enable>,<IP>,<port>,<protocol>
GPRS data limit settings
Parameter
ID
Parameter value
Value type
MIN
MAX
Default
Recommended
Enable GPRS limits
x241
0 (Disable)
1 (Enable)
0
-
U8
Data limit Home
1
10000
100
-
U16
Data limit Roaming
1
10000
10
-
U16
Configuring format:
<Enable>,,
SMS security settings
Parameter
ID
Parameter value
Value type
MIN
MAX
Default
Recommended
SMS Login
x252
Empty
5 char
Empty
-
S8[5]
SMS Password
x253
Empty
5 char
Empty
-
S8[5]
Authorized phone numbers
x260-x269
Empty
16 char
Empty
-
S8[17]
SMS data sending settings
Parameter
ID
Parameter value
Value type
MIN
MAX
Default
Recommended
SMS Data
x250
0 (Disable)
1 (Enable)
0
-
U8
SMS Data send week time schedule
x273
Binary decoding
Binary decoding
-
-
20 byte array
Configuring format:
<x1><x2><x3><x4>......<x19>
Operator list settings
Parameter
ID
Parameter value
Value type
MIN
MAX
Default
Recommended
Preferred Operator
x271
0
99999999
0
-
U32
Black List Operator
x272
0
99999999
0
-
U32
Configuring format: (setparam Y271 X)
X is start position. If no X is set starts from 0 Max 19 operator codes can be set (separated by comma) in one SMS command.
Reading format: (getparam Y271 X)
X values can be 1,2,3. If X = 1, Operator codes from 0-19 are read from configuration and sent via SMS. If X = 2, Operator codes from 20-39 are read from configuration and sent via SMS. If X = 3, Operator codes from 40-49 are read from configuration and sent via SMS. If X = any other, Operator codes from 0-19 are read from configuration and sent via SMS *User must use X, without X value device responds that parameter is wrong or it can respond with wrong operator codes.
Data Acquisition settings
Parameter
ID
Parameter value
Value type
MIN
MAX
Default
Recommended
Data acquisition modes
x010
Min Period (in seconds)
0
9999999
600
-
U32
Min Distance (in meters)
0
65535
0
-
U32
Min Angle (in degrees)
0
180
0
-
U16
Min Speed (in km/h)
0
400
0
-
U16
Min Speed Source
0/1/2/3/4 (0-GPS, 1-LVCAN, 2-ALLCAN, 3-FMS, 4-KLINE)
0
-
U8
Min Saved Records
1
25
10
-
U8
Min Send Period (in seconds)
0
9999999
600
-
U32
Configuring format:
<minperiod>,<mindistance>,<minangle>,<minspeed>,<minspeedsource>,<minsavedrec>,<sendperiod>
Geofencing settings
Parameter
ID
Parameter value
Value type
MIN
MAX
Default
Recommended
Frame Border (in meters)
x020
0
9999999
1
1000
U32
Geofence Overspeed control
x021
0
5
0
-
U8
Geofence Zone #1
x030
Zone #1 Shape
0 (Circle)
1 (Rectangle)
0
-
U32
Zone #1 priority
0
7 (exl. 3)
0
-
U8
0
Low
1
High
2
Panic
4
SW21
5
SW22
6
SW23
7
SW24
Zone #1 Generate Event
0
3
0
-
U8
0
No Event
1
On enter
2
On exit
3
On both
Min Angle (in degrees)
0
180
0
-
U16
Zone #1 Longitude X1 (Rectangle) / X (Circle)
-180
180
0
-
Float
-180
180
0
-
Float
Zone #1 Latitude Y1 (Rectangle) / Y (Circle)
-90
90
0
-
Float
-90
90
0
-
Float
Zone #1 Longitude X2 (Rectangle) / R (Circle)
-180
180
0
-
Float
0
180 / 9999999.99
0
0
Float
Zone #1 Latitude Y2 (Rectangle) / None (Circle)
-90
90
0
-
Float
-
-
-
-
-
Configuring format:
<shape>,<priority>,<generateEvent>,<fx1>,<fy1>,<fx2>,<fy2>
Geofence Zone #2
x031
Same configuration as Geofence Zone #1
Geofence Zone #3
x032
Geofence Zone #4
x033
Geofence Zone #5
x034
Geofence Zone #6
x035
Geofence Zone #7
x036
Geofence Zone #8
x037
Geofence Zone #9
x038
Geofence Zone #10
x039
Geofence Zone #11
x040
Geofence Zone #12
x041
Geofence Zone #13
x042
Geofence Zone #14
x043
Geofence Zone #15
x044
Geofence Zone #16
x045
Geofence Zone #17
x046
Geofence Zone #18
x047
Geofence Zone #19
x048
Geofence Zone #20
x049
Auto Geofencing settings
Parameter
ID
Parameter value
Value type
MIN
MAX
Default
Recommended
Autogeofence
x290
Deactivate By
0 (Ignition)
1 (iButton)
0
-
U8
Activation Timeout (in seconds)
0
65535
60
60
U16
Min Angle (in degrees)
0
180
0
-
U16
Zone #1 priority
0
7
1
1
U8
0
Low
1
High
2
Panic
4
SW21
5
SW22
6
SW23
7
SW24
Zone #1 Generate Event
0
3
0
2
U8
0
No Event
1
On enter
2
On exit
3
On both
Radius (in meters)
0
9999999
100
100
U32
Configuring format:
<deactivateBy>,<tmo>,<priority>,<eventGenerating>,<radius>
Towing Detection settings
Parameter
ID
Parameter value
Value type
MIN
MAX
Default
Recommended
Towing Detection
X917
0 (Disable)
2 (High priority)
0
-
U8
Activation Tmo (min)
0
1440
5
-
-
Ignition Check (sec)
0
60
5
-
-
Duration (ms)
100
5000
1000
1000
-
Acceleration
0.15
5
0.25
0.25 m/s^2
-
Angle (deg.)
0.5
5
1.0
1.0
U8
Make Call Number
0
9
-
-
-
Configuring Format
<priority>,<activationTmo>,<TowingEvtTmo>,<Duration>,<Acceleration>,<TowingAngle>,<TowingCallNr>
iButton List
Parameter
ID
Parameter value
Value type
MIN
MAX
Default
Recommended
Authorized iButtons
500-999
0
FFFFFFFF
0
-
U64
FFFFFFFF
Eco/Green driving settings
Parameter
ID
Parameter value
Value type
MIN
MAX
Default
Recommended
Eco driving type
x910
0
5
0
-
U8
0
Disable
1
No DOUT control
2
DOUT1 control
3
DOUT2 control
4
DOUT3 control
5
DOUT4 control
Eco source
0 (accelerometer)
1 (GPS)
0
-
U8
Max Acceleration Force
5
100
22
25
Float
Max Braking Force
5
100
25
35
Float
Max Cornering Force
5
100
21
-
Float
Acceleration Active Output Duration
0
100
1
-
Float
Breaking Active Output Duration
0
100
1
-
Float
Cornering Active Output Duration
0
100
1
-
Float
Configuring format:
<Eco driving type>,<Ecosource><MaxAcceleration>,<MaxBraking>,<MaxCornering>,<AccOutputDuration>,<BrakingOutputDuration>,<CorneringOutputDuration>
Overspeeding settings
Parameter
ID
Parameter value
Value type
MIN
MAX
Default
Recommended
Overspeeding mode
x911
0
5
0
-
U8
0
Disable
1
No DOUT control
2
DOUT1 control
3
DOUT2 control
4
DOUT3 control
5
DOUT4 control
Max Allowed Speed
0
300
90
-
U16
Configuring format:
<Overspeeding mode>,<MaxSpeed>
Immobilizer settings
Parameter
ID
Parameter value
Value type
MIN
MAX
Default
Recommended
Immobilizer mode
x912
0
5
0
-
U8
0
Disable
1
No DOUT control
2
DOUT1 control
3
DOUT2 control
4
DOUT3 control
5
DOUT4 control
iButton List checking
0 (Disable)
1 (Enable)
0
-
U8
Ignition Timeout
1
255
30
-
U16
Configuring format:
<ImmobMode>,<button_enable>,<TMO>
Excessive Idling settings
Parameter
ID
Parameter value
Value type
MIN
MAX
Default
Recommended
Excessive Idling
x913
0 (Disable)
1 (Enable)
0
-
U8
Time to stationary
0
255
1
-
U16
Time to movement
0 (Disable)
255
1
-
U16
Configuring format:
<Enable>,,
Jamming settings
Parameter
ID
Parameter value
Value type
MIN
MAX
Default
Recommended
Jamming Detection
x914
0
5
0
-
U8
0
Disable
1
No DOUT control
2
DOUT1 control
3
DOUT2 control
4
DOUT3 control
5
DOUT4 control
Sensitivity
1 (low)
3 (High)
0
-
U8
Timeout
1
255
60
-
-
DOUT duration
1
255
0
-
U16
Configuring format:
<Enable>,<Sensitivity>,<Start_TMO>,<DOUT_duration_TMO>
iButton Notification settings
Parameter
ID
Parameter value
Value type
MIN
MAX
Default
Recommended
iButton notification
x915
0
5
0
-
U8
0
Disable
1
No DOUT control
2
DOUT1 control
3
DOUT2 control
4
DOUT3 control
5
DOUT4 control
Timeout
1
65530
0
-
U16
Configuring format:
<Enable/Dout control>,<DOUT TMO>
Crash Detection settings
Parameter
ID
Parameter value
Value type
MIN
MAX
Default
Recommended
Scenario
x918
0 (Disable)
1 (Enable)
0
-
U8
Acceleration Threshold
16
8000
4000
-
U8
Duration
0
600
10
-
U8
Configuring format:
<Scenario>,<Threshold>,< Duration>
Trip settings
Parameter
ID
Parameter value
Value type
MIN
MAX
Default
Recommended
Trip
x280
0 (Disable)
1 (Enable)
0
-
U8
Start Speed
0
255
5
-
U8
Ignition Off Timeout
0
65536
60
-
U16
Remember iButton ID,
while Trip detected
0 (Disable)
1 (Enable)
0
-
U8
Trip Mode
0 (Between)
1 (Continous)
0
-
U8
Configuring format:
<Enable>,<StartStopSpeed>,<IgnitionOffTimeout>,<RememberiButton>,<Mode>
Global and External devices parameters