FMA Device Family Parameter list

From Wiki Knowledge Base | Teltonika GPS


System parameters

Parameter ID Parameter Type Recomended value Value range Value Parameter name
Min Max
1002 Uint8 - 0 2 0 – Ignition Stop Detection Source
1 – Movement sensor
2 – GPS
1003 Uint8 1 0 1 0 – Disable Static navigation
1 – Enable
1004 Uint8 - 0 2 0 – Power voltage Ignition source
1 – Digital input 1
1 – Movement
1005 Uint16 - 0 30000 Voltage Power Voltage High Level
1006 Uint16 - 0 30000 Voltage Power Voltage Low Level
1920 Uint8 - 0 1 0 – Manual Ignition detection (Power voltage)
1 – Auto
1921 Uint8 10 0 65536 Seconds Ignition detection timeout
201 Uint8 1 0 2 0 – after position fix Records Saving/Sending
1 – always
2 – after time sync
202 Uint8 0 0 2 0 – GNSS (all available) GNSS System
1 – GPS only
2 – GLONASS only
1007 Uint32 - 1 259200 Seconds GNSS Fix Timeout
Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1000 Uint8 - 0 2 0 – Disable Sleep settings
1 – Sleep
2 – Deep sleep
200 Uint8 - 1 3000 Minutes Timeout
Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1001 Uint8 - 0 1 0 – 0...10V Analog Input value range
1 – 1...30V
Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1008 Uint8 1 0 1 0 - disabled NTP Time Synchronization
1 – enabled

Records parameters

Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1010 Uint8 - 0 1 0 - From oldest Sorting
1 - From Newest
1011 Uint32 - 0 259200 Seconds Active Data Link Timeout
1012 Uint8 - 0 300 Seconds Server Response Timeout
Bw nb.png ATTENTION! Some GSM operators may disconnect the device from an active data link if the device doesn’t send any data for a very long time, even if active data link timeout is set to maximum value. The amount of time that an operator keeps the link open depends solely on the operator. For example, if active data link timeout is set to maximum, 259200 seconds (72 hours), and the device sends data to server every 86400 seconds (24 hours), the operator might disconnect the link earlier and the device will have to connect to the server anew. This may cost extra, depending on the operator GPRS data charge. It is strongly recommended, when using active data link timeout, that data sending to the server should not be very rare (24 hours or more). If data sending is more frequent, then the operator will not disconnect the device form the server.

GSM parameters

Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1240 Uint8 - 0 1 0 – Disable GPRS content activation
1 – Enable
1142 Char - 0 32 String APN name
1243 Char - 0 30 String APN username
1244 Char - 0 30 String APN password
Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1245 Char - 0 31 String Domain
1246 Uint16 - 0 65535 Number Target Server Port
1247 Uint8 - 0 1 0 – TCP Protocol
1 – UDP
1248 Uint8 - 0 1 0 – Not Allowed Always online
1 – Allowed
Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1252 Char - 0 5 String SMS Login
1253 Char - 0 5 String SMS password
1250 Char - 0 1 0 - Not Allowed SMS data sending settings
1 - Allowed
1273 Uint32 Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF - - Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday. GPRS Week Time
Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1260-1269 Char - 1 digit 16 digits String Authorized phone numbers
150-159 Char - 1 digit 16 digits String SMS Event PreDefined Numbers
1271 X u32 X defines starting position that is changed: If X is from 0 to 49, X means index of operator code which has to be configured. 0 digit 7 digits String Operator list
1272 X u32 X defines starting position that is changed: If X is from 0 to 49, X means index of operator code which has to be configured. 0 digit 7 digits String Operator Black list

Data Acquisition Modes parameters

Home Network GSM operator code "Vehicle on STOP" parameters

Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1540 Uint32 - 0 2592000 Seconds Min Period
1543 Uint8 1 1 225 Records Min Saved Records
1544 Uint32 - 0 2592000 Seconds Send period
1545 Uint32 Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF - - Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday. GPRS Week Time

Home Network GSM operator code "Vehicle on MOVING" parameters

Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1550 Uint32 - 0 2592000 Seconds Min Period
1551 Uint32 - 0 65535 Meters Min distance
1552 Uint16 0 1 160 Angle Min angle
1553 Uint16 1 1 255 Records Min Saved Records
1544 Uint32 - 0 2592000 Seconds Send period
1555 Uint32 Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF - - Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday. GPRS Week Time
1556 Uint16 - 0 255 km/h Min Speed
1557 Uint8 - 0 1 0- GPS Min Speed Source
1- LVCAN

Roaming Network GSM operator code "Vehicle on STOP" parameters

Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1560 Uint32 - 0 2592000 Seconds Min Period
1563 Uint8 1 1 225 Records Min Saved Records
1564 Uint32 - 0 2592000 Seconds Send period
1565 Uint32 Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF - - Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday. GPRS Week Time

Roaming Network GSM operator code "Vehicle on MOVING" parameters

Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1570 Uint32 - 0 2592000 Seconds Min Period
1571 Uint32 - 0 65535 Meters Min distance
1572 Uint16 0 1 160 Angle Min angle
1573 Uint16 1 1 255 Records Min Saved Records
1574 Uint32 - 0 2592000 Seconds Send period
1575 Uint32 Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF - - Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday. GPRS Week Time
1576 Uint16 - 0 255 km/h Min Speed
1577 Uint8 - 0 1 0- GPS Min Speed Source
1- LVCAN

Unknown Network GSM operator code "Vehicle on STOP" parameters

Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1580 Uint32 - 0 2592000 Seconds Min Period
1583 Uint8 1 1 225 Records Min Saved Records
1584 Uint32 - 0 2592000 Seconds Send period
1585 Uint32 Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF - - Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday. GPRS Week Time

Unknown Network GSM operator code "Vehicle on MOVING" parameters

Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1590 Uint32 - 0 2592000 Seconds Min Period
1591 Uint32 - 0 65535 Meters Min distance
1592 Uint16 0 1 160 Angle Min angle
1593 Uint16 1 1 255 Records Min Saved Records
1594 Uint32 - 0 2592000 Seconds Send period
1595 Uint32 Example value: 7F,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF,FF - - Time is defined as 19 byte array. First byte of array defines week days; the rest 18 bytes define timestamps with 10 minute interval. In first byte, first bit (LSB) defines if module should connect to GPRS (send SMS) on Monday, second bit – on Tuesday and so on up to seventh bit – which means Sunday. GPRS Week Time
1596 Uint16 - 0 255 km/h Min Speed
1597 Uint8 - 0 1 0- GPS Min Speed Source
1- LVCAN

Features parameters

Green driving parameters

Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1890 Uint8 - 0 1 0 – Disable Scenario settings
1 – Enable
1891 Uint8 - 0 2 0 - disable Digital Output Control
1 - DOUT1
2 - DOUT2
1909 Uint8 - 0 1 0 - GPS Source
1 - Accelerometer
1892 Float 0.25 0.25 0.85 mG Max Acceleration Force
1893 Float 0.35 0.25 0.85 mG Max Braking Force
1894 Float 0.2 0.1 1.0 mG Max Cornering Force

Overspeeding scenario parameters


Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1895 Uint8 0 0 1 0 – Disable Scenario settings
1 – Enable
1896 Uint8 - 0 2 0 – None Digital Output control
1 – DOUT 1
2 – DOUT 2
1897 Uint16 - 0 260 km/h Max speed

Jamming scenario parameters


Parameter ID Parameter Type Recommended Value Value range Value Parameter name
Min Max
1898 Uint8 - 0 1 0 – Disable Scenario settings
1 – Enable
1899 Uint8 - 0 2 0 – None Digital Output control
1 – DOUT1
2 – DOUT2
1900 Uint8 - 0 2 0 – Low sensitivity (50 RSSI) Jamming sensitivity
1 – Medium sensitivity (30 RSSI)
2 – High sensitivity (10 RSSI)
1901 Uint16 60 0 65535 Seconds Jamming Timeout
1902 Uint16 0 0 65535 Seconds Jamming Pulse Duration

Immobilizer scenario parameters


Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1903 Uint8 - 0 1 0 – Disable Scenario settings
1 – Enable
1904 Uint8 - 0 2 0 – Disable Digital Output Control
1 – DOUT1
2 – DOUT2
1905 Uint8 - 0 1 0 – Disable iButton list checking
1 – Enable
1906 Uint16 30 5 65353 Seconds Ignition Off Timeout

iButton read notification

Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1907 Uint8 - 0 1 0 - Disabled iButton detect
1 - Enabled
1908 Uint8_t 0 0 1 0 - Disabled Digital Output Control
1 - DOUT1
2 - DOUT2

Trip scenario parameters


Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1280 Uint8 - 0 1 0 – Disable Scenario settings
1 – Enable
1281 Uint8 - 0 255 km/h Start speed
1282 Uint16 - 0 65535 Seconds Ignition off timeout
1283 Uint8 - 0 1 0 – Not Continuous distance counting
1 – Continuous
1284 Uint8 - 0 1 0 – Disable Remember iButton ID
1 – Enable
1285 Uint8 - 0 - Meters Odometer Value

AutoGeofencing scenario parameters

Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1101 Uint8 1 0 1 0 – Disable Scenario Settings
1 – Enable
1102 Uint16 60 0 65535 0 – Disable Activation Timeout
1100 Uint8 - 0 1 0 – Ignition Deactivation Source
1 – Enable
1103 Uint8 1 0 1 0 - Low AutoGeofence event priority
1 - hight
1104 Uint8 2 0 3 0 - No Event AutoGeofence event generating
1 - On entering zone
2 - On both
3 - On both
1105 Uint32 100 0 1000000 Meters Radius

iButton list

Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
3500-3999 Uint64 - 0 FFFFFFFF FFFFFFFF 0 – iButton ID iButton list

Manual Geofence

Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1020 Uint32 1000 0 1000000 Border value meters Frame border
1030 Uint8 - 0 1 0 - Circle Shape type
1 - Rectangle
1031 Uint8 - 0 2 0 – Low Priority
1 – High
2 – Panic
1032 Uint8 - 0 3 0 - No event Generate event
1 - On entering zone
2 - On exiting zone
3 - On both
1033 float - -180 180 Rectangle left down corner X coordinate Longitude X1
Or X1 Coordinate circle middle point
1034 float - -90 90 Rectangle left down corner Y1 coordinate latitude Y1
Or Y1 Coordinate circle middle point
1035 float - -180 180 Rectangle right upper corner X2 coordinate longitude X2
1035 float 1000 0 1000000 X2 coordinate radius of circle longitude X2
1036 float - -90 90 Rectangle right upper corner Y2 coordinate latitude Y2
If circle ID 1036 is not used

Similarly to a group defined in the upper table:

Zone number Parameter
Shape Priority Generate event X1 Y1 X2 Radius Y2
1 1030 1031 1032 1033 1034 1035 1035 1036
2 1040 1041 1042 1043 1044 1045 1045 1046
3 1050 1051 1052 1053 1054 1055 1055 1056
4 1060 1061 1062 1063 1064 1065 1065 1066
5 1070 1071 1072 1073 1074 1075 1075 1076



I/O parameters

I/O Element Number I/O element parameters
Digital Input 1 1300-1305
Digital Input 2 1310-1315
Digital Input 3 1320-1325
Analog Input 1 1330-1335
Digital Output 1 1340-1345
Digital Output 2 1350-1355
GNSS PDOP 1360-1365
GNSS HDOP 1370-1375
External Voltage 1380-1385
GNSS Power 1390-1395
Movement Sensor 1400-1405
Trip distance 1410-1415
GSM Operator 1420-1425
Speed (Km/h) 1430-1435
iButton ID 1440-1445
Mode 1450-1455
GSM Signal 1460-1465
Deep Sleep 1470-1475
Cell ID 1480-1485
Area Code 1490-1495
Dallas Temperature 1 1500-1505
Reserved 1510-1515
Reserved 1520-1525
Battery Voltage 1530-1535
Battery Charging Current 1110-1115
Ignition 1120-1125
Total Distance 1130-1135
Reserved IO1 1140-1145
Reserved IO2 1150-1155
RFID 1160-1165
LLS Fuel1 1720- 1725
LLS Temp1 1730- 1735
LLS Fuel2 1740- 1745
LLS Temp2 1750- 1755
LLS Fuel3 1760- 1765
LLS Temp3 1770- 1775
LLS Fuel4 1780- 1785
LLS Temp4 1790- 1795
LLS Fuel5 1800- 1805
LLS Temp5 1810- 1815
Dallas Temperature 2 1820- 1825
Dallas Temperature 3 1830- 1835
Dallas Temperature 4 1840- 1845
Dallas Temperature ID 1 1850- 1855
Dallas Temperature ID 2 1860- 1865
Dallas Temperature ID 3 1870- 1875
Dallas Temperature ID 4 1880- 1885


Parameters

{