How to connect FMB640 with FMS Cable

From Wiki Knowledge Base | Teltonika GPS
Main Page > EOL Products > FMB640 > FMB640 Manual > How to connect FMB640 with FMS Cable

Description

Cable is a standardized heavy duty vehicle FMS 12-pin connector, for connecting FMX640 with one plug and receiving vehicle information through CAN line and K-line, along with powering the device and getting Ignition detection. This ensures easier connection and does not violate the factory warranty.

Fms-cable-scheme.jpg

FMS Plug Location

Even though the FMS cable is standardized cable – its placement in the vehicle might differ depending on manufacturer and depending on vehicle trim level.

We were able to identify the most common places for the FMS plug – refer to the examples bellow:

  1. Behind the Fuse panel on passenger side – for Example SCANIA S/R/G/P Euro6 Series: Scania R-series 1.3.png
  2. Near the Fuse panel on passenger side – for example DAF XF Euro6: DAF XF 1.3.png
  3. Behind the Radio on lower deck – for example Volvo FH Euro5 and Renault T Euro6: Volvo FH 1.3.png
  4. Behind the Tachograph on upper deck – for example Mercedes Actros MP5 Euro6: Mercedes Actros 1.3.png


Device configuration

In configurator go to "CAN\ Tachograph" tab and in "Tachograph Settings" select "Front Panel" as "DDD Download Source":

Frontgif.gif

This way DDD files will be downloaded from the tachograph Front Interface.
To read live data, in "Tachograph Data" tab of the configurator, change Vehicle Data Priority Settings -> "K Line Priority" to "Priority 1" Vehicle Data Priority Settings K-line Priority1.png

Final Steps

In order to check if the connection/activation/configuration is correct, send "tachocheck" SMS command. If everything is correct, the device will reply:

KLN:111,0000, K-Line:0
The ones mean the same as in CAN_2:111,.... tachocheck response:
CAN_2:[TRC],[ABCD], K-Line:[K]

[T] – Tachograph presence on bus:
• 0 – Tachograph doesn’t respond on bus;
• 1 – Tachograph responds on bus.

[R] – Response to Open Remote Session validity check:
• 0 – Wrong or unknown response (failed to open Remote Session);
• 1 – Tachograph responds positively (Remote Session opened successfully).

[C] – Response to Close Last Authentication Session validity check:
• 0 – Wrong or unknown response (failed to close last authentication session);
• 1 – Last authentication session closed successfully, device is ready to open new authentication session.

The other values will always be zero because there is no FMS data and the K-line is used for front download.