GH5200 Parameter list

From Teltonika Telematics Wiki
Revision as of 15:21, 28 December 2023 by Arnas.Zeb (talk | contribs) (Text replacement - "Bluetooth(?!®)" to "Bluetooth®")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > Autonomous Trackers > GH5200 > GH5200 Manual > GH5200 Parameter list

System parameters

System Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
138 Uint8 1 0 2 0 – Ignition Movement Source
1 – Accelerometer
2 – GNSS
3 – CAN speed
133 Uint8 0 0 1 0 – GNSS Speed Source
1 – CAN
107 Uint8 0 0 2 0 – After Position Fix Records Saving/Sending without TS
1 – Always
2 – After Time Sync
123 Uint8 0 0 1 0 – Disable PDOP filter
1 – Enable
124 Uint16 0,7 0 99 - PDOP filter Threshold
108 Uint8 1 0 1 0 – Disable LED indication
1 – Enable
109 Uint8 10 1 15 0 – Undefined GNSS source
1 – Beidou only
2 – Glonass only
3 – Glonass and Beidou not allowed
4 – Galileo only
5 – Galileo and Beidou
6 – Galileo and Glonass
7 – Galileo, Glonass and Beidou not allowed
8 – Gps only
9 – Gps and Beidou
10 – Gps and Glonass
11 – Gps, Glonass and Beidou not allowed
12 – Gps and Galileo
13 – Gps, Galileo and Beidou
14 – Gps, Galileo and Glonass
15 – Gps, Galileo, Glonass and Beidou and not allowed
111 Uint8 1 0 1 0 – Range 15V Analog Input Value Range
1 – Range 150V
113 Uint8 1 0 1 0 – Codec 8 Data Protocol
1 – Codec 8 Extended
110 Uint8 0 0 1 0 – On need Battery Charge Mode
1 – After Ignition ON
2 – Always
114 Uint8 1 0 1 0 – Disable Power On By USB/Charger
1 – Enable
131 Uint8 10 5 10 5 – Digital Input 3 + Digital Input 4 Input/Output Mode
6 – Digital Output 1 + Digital Input 4
9 – Digital Input 3 + Digital Output 2
10 – Digital Output 1 + Digital Output 2

Static Navigation Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
106 Uint8 1 0 1 0 – Disable Static navigation
1 – Enable
112 Uint8 0 0 1 0 – Movement Source Static Navigation Source
1 – Ignition Source

Call Duration Limits

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
3030 Uint16 0 – Disabled 0 65535 Seconds Other Calls Duration
3031 Uint16 0 – Disabled 0 65535 Seconds Alarm Button Call Action Duration Limit
3032 Uint16 0 – Disabled 0 65535 Seconds Power Button Call Action Duration Limit
3033 Uint16 0 – Disabled 0 65535 Seconds Button 1 Call Action Duration Limit
3034 Uint16 0 – Disabled 0 65535 Seconds Button 2 Call Action Duration Limit
3035 Uint16 0 – Disabled 0 65535 Seconds Button 3 Call Action Duration Limit

Sleep Mode

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
102 Uint8 2 0 4 0 – Disable Sleep settings
1 – GPS sleep
2 – Deep sleep
3 – Online Deep sleep
4 – Ultra sleep
132 Uint8 2 0 2 0 - Movement only Sleep Exit Source
1 - Alarm button only
2 - Movement + Alarm button
103 Uint16 1 1 3000 Minutes Timeout
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
104 Uint8 30000 13200 100000 mV High Voltage
105 Uint8 13200 0 30000 mV Low Voltage
101 Uint16 2 1 103 1 - DIN1 Low Voltage
2 - Accelerometer
3 - DIN1 + Accelerometer
4 - Power Voltage
5 - DIN1 + Power Voltage
6 - Accelerometer + Power Voltage
7 - DIN1 + Accelerometer + Power Voltage
32 - DIN3
33 - DIN1 + DIN3
34 - Accelerometer + DIN3
35 - DIN1 + Accelerometer + DIN3
36 - Power Voltage + DIN3
37 - DIN1 + Power Voltage + DIN3
38 - Accelerometer + Power Voltage + DIN3
39 - DIN1 + Accelerometer + Power Voltage + DIN3
64 - DIN4
65 - DIN1 + DIN4
66 - Accelerometer + DIN4
67 - DIN1 + Accelerometer + DIN4
68 - Power Voltage + DIN4
69 - DIN1 + Power Voltage + DIN4
70 - Accelerometer + Power voltage + DIN4
71 - DIN1 + Accelerometer
96 - DIN3 + DIN4
97 - DIN1 + DIN3 + DIN4
98 - Accelerometer + DIN3 + DIN4
99 - DIN1 + Accelerometer + DIN3 + DIN4
100 - Power Voltage + DIN3 + DIN4
101 - DIN1 + Power Voltage + DIN3 + DIN4
102 - Accelerometer + Power Voltage + DIN3 + DIN4
103 - DIN1 + Accelerometer + Power Voltage + DIN3 + DIN4

Movement Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
19001 Uint16 1 1 60 Seconds Movement Start Delay
19002 Uint16 60 5 300 Seconds Movement Stop Delay
19000 Uint16 2 0 4 0 – Minimal Accelerometer sensitivity in sleep
1 – Reduced
2 – Normal
3 – Increased
4 – Maximum

Time Synchronization

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
901 Uint8 3 0 24 Hours NTP Resync
902 Char "avl1.teltonika.lt" 0 55 String NTP server 1
903 Char "pool.ntp.org" 0 55 String NTP server 2
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
169 Uint16 2 0 2 0 - Disabled Accelerometer Auto Calibration
1 - Once
2 - Continuous
170 Uint16 1 0 1 0 - Disable Gravity Filter
1 - Enable

Tracking Mode

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
909 Uint8 0 0 1 0 - Performance Power Saving mode
1 - Low Power
905 Uint16 3 0.1 5 Value GPS accuracy: HDOP PDOP VDOP
906 Uint16 5 4 255 Value GPS Satellites Quantity


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
140 Uint8 0 0 1 0 – Disable Timestamp Backup
1 – Enable

Heart Rate Alert

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1800 Uint8 0 1 0 0 – Disable Heart Rate Alert Enable
1 – Enable
1801 Uint8 - - 12 Symbols Value Mac Address
1802 Uint8 600 30 86400 Seconds Scan Period
3006 Uint8 UTC+0 UTC-12 UTC+14 Time Zone SMS Event/Xiaomi Mi Band 2 Time Zone
1803 Uint8 50 0 [Value of ID1804] BPM Min Heart rate
1804 Uint8 130 [Value of ID1803] 255 BPM Max Heart rate
1805 Uint8 0 0 10 Number Call To

GPRS

GPRS Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2000 Uint8 1 0 1 0 – Disable GPRS context
1 – Enable
2001 Char "" 0 32 String APN
2002 Char "" 0 32 String APN username
2003 Char "" 0 32 String APN password
2016 Uint8 0 0 1 0 - Normal (PAP) -
1 - Secured (CHAP)

Server Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2004 Char "" 0 55 String Domain
2005 Uint16 0 0 65535 Number Port
2006 Uint8 0 0 1 0 – TCP Protocol
1 – UDP
2020 Uint8 0 0 1 0 – None Encryption
1 – TLS/DTLS

Second Server Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2010 Uint8 0 0 2 0 - Disable Backup Server Mode
1 - Backup
2 - Duplicate
2007 Char "" 0 55 String Backup Server Domain
2008 Uint16 0 0 65535 Number Backup Server Port
2009 Uint8 0 0 1 0 - TCP Backup Server Protocol
1 - UDP
2021 Uint8 0 0 1 0 – None Encryption
1 – TLS/DTLS

Records Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1000 Uint32 30 30 259200 Seconds Open link timeout
1001 Uint16 30 5 300 Seconds Response timeout
1003 Uint16 0 0 30 Seconds Network Ping Timeout
1002 Uint8 0 0 1 0 – Newest Sort by
1 – Oldest
1004 Uint8 1 0 1 0 – TCP/IP ACK Type
1 – AVL
1008 Uint8 0 0 1 0 – Disable Permanent Link
1 – Enable

FOTA WEB Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13003 Uint8 1 0 1 0 - Disable FOTA WEB Status
1 – Enable
13000 Char fm.teltonika.lt 0 55 String FOTA WEB Domain
13001 Uint16 5000 0 65535 Number FOTA WEB Port
13002 Uint16 720 30 65535 Minutes FOTA WEB Period

Data Acquisition

On Stop

Parameter ID Parameter Type Default value Value range Value Parameter name Network GSM operator
Min Max
10000 Uint16 3600 0 65535 Seconds Min Period Home
10004 Uint8 1 1 255 Value Min Saved Records
10005 Uint16 120 0 65535 Seconds Send Period
10100 Uint16 3600 0 65535 Seconds Min Period Roaming
10104 Uint8 1 1 255 Value Min Saved Records
10105 Uint16 0 0 65535 Seconds Send Period
10200 Uint16 3600 0 65535 Seconds Min Period Unknown
10204 Uint8 1 1 255 Value Min Saved Records
10205 Uint16 120 0 65535 Seconds Send Period

Moving

Parameter ID Parameter Type Default value Value range Value Parameter name Network GSM operator
Min Max
10050 Uint16 300 0 65535 Seconds Min Period Home
10051 Uint16 100 0 65535 Meters Min Distance
10052 Uint8 10 0 180 Degrees Min Angle
10053 Uint8 10 0 100 Value Min Speed Delta
10054 Uint8 1 1 255 Value Min Saved Records
10055 Uint16 120 0 65535 Seconds Send Period
10150 Uint16 300 0 65535 Seconds Min Period Roaming
10151 Uint16 100 0 65535 Meters Min Distance
10152 Uint8 10 0 180 Degrees Min Angle
10153 Uint8 10 0 100 Value Min Speed Delta
10154 Uint8 1 1 255 Value Min Saved Records
10155 Uint16 120 0 65535 Seconds Send Period
10250 Uint16 300 0 65535 Seconds Min Period Unknown
10251 Uint16 100 0 65535 Meters Min Distance
10252 Uint8 10 0 180 Degrees Min Angle
10253 Uint8 10 0 100 Value Min Speed Delta
10254 Uint8 1 1 255 Value Min Saved Records
10255 Uint16 120 0 65535 Seconds Send Period

On Demand tracking

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
10990 Uint8 10 5 60 Seconds Tracking period
10991 Uint16 600 300 3600 Seconds Tracking duration

SMS/Call settings

SMS Data Sending

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
3000 Uint8 0 0 1 0 – Disable Allow SMS data sending
1 – Enable
3001 Char "" 0 16 String Data Send Number

SMS Commands

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
3003 Char "" 0 5 String Login
3004 Char "" 0 5 String Password
3006 Uint16 UTC+00:00 UTC-12:00 UTC+13:00 Time zone SMS event Time Zone

Incoming Call Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
3005 Uint8 0 0 8 0 – Do nothing Incoming call action
1 – Hangup
2 – Report position
3 – Auto answer
4 – Man-Down
5 – Info SMS
6 – Power Off
7 – Send GPRS Data
8 – Auto Geofencing Off


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
3008 Uint8 "" 0 10 Predefined number GSM Number

Outgoing Call Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
3005 Uint8 0 0 1 0 – Disable Out going Call in Loudspeaker
1 – Enable

Audio control

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13050 Uint8 40 0 100 % Indication Volume
13051 Uint8 40 0 100 % Normal Speaker Volume
13052 Uint8 80 0 100 % Loud Speaker Volume

Authorized Numbers

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
4000-4199 Char "" 0 16 String Authorized number

GSM Predefined Numbers

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
6000-6009 Char "" 0 16 String Predefined number

GSM Operations

Roaming Operator List

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
5000-5049 Uint32 0 0 6 Number Roaming Operator List

Operator Black List

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
5500-5549 Uint32 0 0 6 Number Operator Black List

Common settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2018 Uint8 0 0 1 0 – Disable Ban List Control
1 – Enable

Features

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11000 Uint16 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11004 Uint8 2,2 0,5 10 m/s² Max acceleration
11005 Uint8 2,5 0,5 10 m/s² Max Braking
11006 Uint8 2,1 0,5 10 rad/s Max Cornering
11007 Uint16 0 0 1 0 – GPS Source
1 – Accelerometer
11008 Uint16 0 0 1 0 – Disable Eco/Green Driving Duration
1 – Enable
11003 Uint16 0 0 2 0 – None Output Control
1 – DOUT1
2 – DOUT2
11001 Uint8 200 100 5000 miliseconds DOUT ON Duration
11002 Uint8 200 0 5000 miliseconds DOUT OFF Duration
7034 Uint16 "" 0 10 Predefined number Send SMS to
8034 String Green Driving 0 160 Char SMS text


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11300 Uint8 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11303 Uint8 1 0 1 0 – Disable Eventual Records
1 – Enable
11305 Uint8 60 0 65535 Seconds Time until Jamming Event Detection
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11720 Uint8 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11721 Uint8 0 0 1 0 – On Exit UGenerate aven
1 – On Entrance
2 – On Both
11722 Uint8 1 0 30 Seconds Pre-alarm timeout
11723 Uint8 1 0 30 Seconds Time to Stable
11724 Uint8 1 1 5 Seconds Buzzer ON
11725 Uint8 5 2 30 Seconds Buzzer period
7729 Uint16 "" 0 10 Predefined number Send SMS to
8729 String Unauthorized movement 0 160 Char SMS Text

Over speeding

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11100 Uint8 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11104 Uint32 90 0 6 km/h Max speed
11103 Uint16 0 0 2 0 – None Output Control
1 – DOUT1
2 – DOUT2
11101 Uint8 200 100 5000 miliseconds DOUT ON Duration
11102 Uint8 200 0 5000 miliseconds DOUT OFF Duration
7032 Uint16 "" 0 10 Predefined Number Send SMS to
8032 String Overspeeding 0 160 Char SMS Text

Alarm

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
7245 Uint16 "" 0 10 Predefined Number Send SMS to
8245 String Alarm 0 160 Char SMS Text
11711 Uint8 0 0 1 0 – Call Order priority
1 – Record
11712 Uint16 "" 0 10 Predefined Number Call to

Additional features

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
251 Uint32 0 0 4294967295 number User ID

Power Off/On

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13086 Uint8 "" 0 2 0 – Disable Event On Power Off
1 – Enable
7310 Uint16 "" 0 10 Predefined Number Send SMS to
8310 String Power! Val %val IM %imei 0 160 Char SMS Text

ManDown

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
12100 Uint8 0 0 1 0 – Disable Scenario Settings
1 – Enable
127 Uint8 0 0 1 0 – Disable Mandown/No/Movement while charging
1 – Enable
12110 Uint8 1 0 2 0 – On Exit Generate event
1 – On Entrance
2 – On both
12101 Uint8 0 0 1 0 – Horizontal Position
1 – Vertical
12102 Uint32 60 30 150 Degrees Angle
12111 Uint32 5 0 600 Seconds Silent pre-alarm delay
12103 Uint32 3 0 65500 Seconds Pre-alarm timeout
7222 Uint16 "" 0 10 Predefined Number Send SMS to
8222 String ManDown 0 160 Char SMS Text
12104 Uint8 0 0 1 0 – Call Order priority
1 – Record
12105 Uint16 "" 0 10 Predefined Number Call to

Last Known Position

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
51720 Uint8 0 0 1 0 – Disable Scenario Settings
1 – Enable


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11500 Uint8 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11501 Uint8 1 0 1 0 – Disable Eventual Records
1 – Enable
11502 Uint8 0 0 1 0 – Simple Unplug Detection Mode
1 – Advanced
11504 Uint8 0 0 1 0 – Disable Buzzer Control
1 – Enable
11505 Uint8 200 0 65535 Seconds Buzzer ON duration
7036 Uint16 "" 0 10 Predefined number Send SMS to
8036 String Unplug 0 160 Char SMS Text


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11730 Uint8 0 0 1 0 – Disable Enable/Disable SIM Tamper Protection
1 – Enable
11731 Uint8 0 0 3600 Seconds ICCID

Event Notification

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13053 Uint8 "" 0 7 0 – None Event Notification
1 – Alarm
2 – ManDown
3 – ManDown & Alarm
4 – Movement Event
5 – Movement Event & Alarm
6 – Movement Event & ManDown
7 – Movement Event & ManDown & Alarm
60257 Uint8 0 0 1 0 – GPRS or SMS SMS sending method
1 – GPRS and SMS
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13059 Uint8 "" 0 1 0 – Nobody Call After Answer
1 – Number 2
2 – Number 2 + Number 3
3 – Number 2 + Number 3 + Number 4
4 – Number 2 + Number 3 + Number 4 + Number 5
5 – Number 3
6 – Number 3 + Number 4
7 – Number 3 + Number 4 + Number 5
8 – Number 4
9 – Number 4 + Number 5
10 – Number 5
13055 Uint8 0 0 1 0 – Disable Inform When Answered
1 – Enable
13057 String Answered 0 160 Char SMS Text
13056 Uint8 0 0 1 0 – Disable Inform When Not Answered
1 – Enable
13058 String No answer 0 160 Char SMS Text

SMS Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13060 Uint16 "" 0 10 Predefined Number SMS Number 1
13061 Uint16 "" 0 10 Predefined Number SMS Number 2
13062 Uint16 "" 0 10 Predefined Number SMS Number 3
13063 Uint16 "" 0 10 Predefined Number SMS Number 4
13064 Uint16 "" 0 10 Predefined Number SMS Number 5

Call Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13080 Uint16 "" 0 10 Predefined Number Call Number 1
13081 Uint16 "" 0 10 Predefined Number Call Number 2
13082 Uint16 "" 0 10 Predefined Number Call Number 3
13083 Uint16 "" 0 10 Predefined Number Call Number 4
13084 Uint16 "" 0 10 Predefined Number Call Number 5
13066 Uint32 5 5 300 Seconds Call Answer Timeout
13054 Uint32 1 1 10 Number Call repeat

Movement Event

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
12106 Uint8 0 0 1 0 – Disable Scenario Settings
1 – Enable
12108 Uint8 0 0 1 0 – Movement Event Mode
1 – No Movement Event
12107 Uint32 30 30 65500 Seconds Timeout
7294 Uint16 "" 0 10 Predefined Number Send SMS to
8294 String Movement Event 0 160 Char SMS Text


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
12000 Uint16 0 0 2 0 – None Scenario Settings
1 – DOUT1
2 – DOUT2
12002 Uint8 5 0 2147483648 seconds Duration Timeout
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11700 Uint16 0 0 3 0 – Disable Scenario Settings
1 – Low Priority
2 – High Priority
3 – Panic Priority
11701 Uint16 1 0 1 0 – Disable Eventual Records
1 – Enable
11702 Uint16 0 0 2 0 – None Output Control
1 – DOUT1
2 – DOUT2
11703 Uint16 0 0 1 0 – Disable iButton List Check
1 – Enable
11709 Uint16 1 0 1 0 – Disable Depend on Ignition
1 – Enable
7140 Uint16 "" 0 10 Predefined number Send SMS to
8140 String Immobilizer 0 160 Char SMS text
60068 Uint8 30 1 65535 Seconds Ignition Off Timeout
Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11704 Uint16 0 0 2 0 – None Output Control
1 – DOUT1
2 – DOUT2
11705 Uint8 200 100 5000 Miliseconds DOUT ON Duration
11706 Uint16 0 0 1 0 – Disable iButton List Check
1 – Enable
11707 Uint16 0 0 1 0 – Disable Depend On Ignition
1 – Enable


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13401 Uint16 0 0 2 0 – None DOUT Control
1 – DOUT1
2 – DOUT2
13402 Uint16 0 0 2 0 – None DOUT Deactivation Via DIN
1 – DOUT1
2 – DOUT2
13403 Uint8 5 0 65500 Seconds Ignition Off Timeout

Bluetooth Home Zone Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
322 Uint8 0 0 3 0 – None BLE Geofence
1 – ELA MOV
2 – Ela Sensors
3 – Beacons
324 Uint8 -60 -100 0 dBm Home Zone RSSI
329 Uint8 60 40 65535 Seconds Time-without-beacon
325 Uint8 0 0 2 0 – On Exit Generate Event
1 – On Entrance
2 – On both
326 Uint16 "" 0 10 Predefined Number Make Call To
7470 Uint16 "" 0 10 Predefined Number Send SMS to
8470 String Home Zone Alarm 0 160 Char SMS Text

EYE Sensors filtered by Name List

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
70076 Uint8 0 0 3 0 – Disabled Sensor Configuration
1 – Custom Sensors
2 – EYE Sensors
3 – Custom and EYE Sensors
70077 Uint8 0 0 3 0 – Disabled EYE Sensor Filter
1 – Name
2 – MAC
3 – Name and MAC

Data Clear Period

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
70057 Uint16 10 0 65535 Defines period in seconds, for how long sensor has to be not detected in order to remove it from EYE Sensor List. Data clear period

RSSI

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
70005 Int8 0 0 -100 Defines period in seconds, for how long sensor has to be not detected in order to remove it from EYE Sensor List. Data clear period

Record Period parameters

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
258 Uint32 60 0 2592000 Defines how often to create EYE Sensor List records while vehicle is moving in seconds On Move
259 Uint32 60 0 2592000 Defines how often to create EYE Sensor List records while vehicle is not moving in seconds On Stop

EYE Sensor Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
70067 Bool 0 0 1 Includes temperature value, received from EYE Sensor Temperature
70068 Bool 0 0 1 Includes humidity value, received from EYE Sensor Humidity
70069 Bool 0 0 1 Includes magnetic field presence value around EYE sensor Magnet
70083 Bool 0 0 1 Includes value, which represents how many times EYE Sensor has detected magnetic sensor trigger Magnet Trigger Count
70070 Bool 0 0 1 Includes movement value, which displays if EYE Sensor is detecting movement Movement
70071 Bool 0 0 1 Includes value, which represents how many times EYE Sensor has detected movement Movement Count
70072 Bool 0 0 1 Includes pitch value, received from EYE Sensor accelerometer Pitch
70073 Bool 0 0 1 Includes roll value, received from EYE Sensor accelerometer Roll
70074 Bool 0 0 1 Includes low battery value received from EYE Sensor. Low Battery
70075 Bool 0 0 1 Includes EYE Sensor battery voltage Battery Voltage

EYE Name List

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
70006...70030 Char - 0 characters 10 characters Configure up to 50 different EYE Sensor Name filters EYE Name List

Amber Alert

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
601 Uint8 1800 0 86400 Seconds Timeout
602 Uint8 300 0 86400 Seconds Pre-Alarm
603 Uint8 0 0 1 0 – Call Order Priority
1 – Record
607 Uint8 0 0 1 0 – Disable Deactivate after alarm call
1 – Enable
605 Uint16 "" 0 10 Predefined Number Initial call number
606 Uint16 "" 0 10 Predefined Number Alarm call number
7339 Uint16 "" 0 10 Predefined Number Send SMS to
8339 String %date %datetime Lon %flon LatP %flat Amber Alert Val %val Timout %param601 0 160 Char SMS Text

Proximity Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
327 Uint8 0 0 1 0 – Disable Proximity detection
1 – Enable
1116 Uint8 0 0 255 - Proximity Group ID
328 Uint8 -60 -100 0 dBm Proximity RSSI
331 Uint8 0 0 20 - Proximity RSSI exit threshold
332 Uint8 0 0 1 0 – Disable Proximity RSSI moving average enable
1 – Enable
333 Uint8 5 0 60 - Proximity RSSI moving average samples
330 Uint8 1 0 1 0 – Disable Proximity while charging
1 – Enable
7471 Uint16 "" 0 10 Predefined Number Send SMS to
8471 String Proximity 0 160 Char SMS Text

Lockdown Indication Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
323 Uint8 30 0 65500 Seconds Pre-Alarm

Last Known Position

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
51720 Uint8 0 0 1 0 – Disable Scenario Settings
1 – Enable


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
321 Uint8 0 0 1 0 – Disable Tamper Detection
1 – Enable
320 Uint16 "" 0 10 Predefined Number Call to
7475 Uint16 "" 0 10 Predefined Number Send SMS to
8475 String Tamper 0 160 Char SMS Text

Auto Geofence

Auto Geofence

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
20000 Uint8 0 0 3 0 – Disable Priority
1 – Low Priority
2 – High Priority
3 – Panic Priority
20002 Uint8 1 0 1 0 – Disable Eventual records
1 – Enable
20001 Uint8 0 0 2 0 - On exiting zone Generate Event
1 - On entering zone
2 - On both
20003 Uint8 60 0 65535 Seconds Activation Timeout
20004 Uint16 100 5 1000000 Meters Radius
20005 Uint8 0 0 2 0 - Power Voltage Generate Event
1 - Digital Input1
2 - Engine RPM
7030 Uint64 "" 0 10 Predefined Number Send SMS to
8030 String AutoGeofence 0 160 Text SMS text
20006 Uint8 0 0 1 0 – Disable Call Settings
1 – Enable
20007 Uint16 "" 0 10 Predefined Number Call to

Manual Geofence

Manual Geofence Selection

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
20100 Uint8 0 0 3 0 – Disabled Priority
1 – Low
2 – High
3 – Panic
20101 Uint8 1 0 3 0 - No event Generate Event
1 - On exiting zone
2 - On entering zone
3 - On both
20102 Uint8 1 0 1 0 - Disable Eventual records
1 - Enable
20103 Uint32 1 0 1000000 Border value Frame border
20104 Uint8 1 0 1 0 - Circle Shape type
1 - Rectangle
20105 Uint32 5 0 1000000 Metres Radius
20106 Double 0 -180 180 Coordinate X1
20107 Double 0 -90 90 Coordinate Y1
20108 Double 0 -180 180 Coordinate X2
20109 Double 0 -90 90 Coordinate Y2
20110 Uint8 0 0 1 0 - Disable Overspeeding
1 - Enable
20111 Uint16 90 0 1000 km/h Max allowed speed
7025 Uint8 0 0 10 Phone number Send SMS to
8025 String Geozone Zone # 0 160 Text SMS text

Similarly to a group defined in the upper table:

Zone number Parameter ID
Priority Event generating Eventual records Frame border Shape type Radius X1 Y1 X2 Y2 Overspeeding Max allowed speed Send sms to SMS text
1 20100 20101 20102 20103 20104 20105 20106 20107 20108 20109 20110 20111 7025 8025
2 20120 20121 20122 20123 20124 20125 20126 20127 20128 20129 20130 20131 7026 8026
3 20140 20141 20142 20143 20144 20145 20146 20147 20148 20149 20150 20151 7027 8027
4 20160 20161 20162 20163 20164 20165 20166 20167 20168 20169 20170 20171 7028 8028
5 20180 20181 20182 20183 20184 20185 20186 20187 20188 20189 20190 20191 7029 8029
6 20200 20201 20202 20203 20204 20205 20206 20207 20208 20209 20210 20211 7071 8071
7 20220 20221 20222 20223 20224 20225 20226 20227 20228 20229 20230 20231 7072 8072
8 20240 20241 20242 20243 20244 20245 20246 20247 20248 20249 20250 20251 7073 8073
9 20260 20261 20262 20263 20264 20265 20266 20267 20268 20269 20270 20271 7074 8074
10 20280 20281 20282 20283 20284 20285 20286 20287 20288 20289 20290 20291 7075 8075
11 20300 20301 20302 20303 20304 20305 20306 20307 20308 20309 20310 20311 7076 8076
12 20320 20321 20322 20323 20324 20325 20326 20327 20328 20329 20330 20331 7077 8077
13 20340 20341 20342 20343 20344 20345 20346 20347 20348 20349 20350 20351 7078 8078
14 20360 20361 20362 20363 20364 20365 20366 20367 20368 20369 20370 20371 7079 8079
15 20380 20381 20382 20383 20384 20385 20386 20387 20388 20389 20390 20391 7080 8080
16 20400 20401 20402 20403 20404 20405 20406 20407 20408 20409 20410 20411 7081 8081
17 20420 20421 20422 20423 20424 20425 20426 20427 20428 20429 20430 20431 7082 8082
18 20440 20441 20442 20443 20444 20445 20446 20447 20448 20449 20450 20451 7083 8083
19 20460 20461 20462 20463 20464 20465 20466 20467 20468 20469 20470 20471 7084 8084
20 20480 20481 20482 20483 20484 20485 20486 20487 20488 20489 20490 20491 7085 8085
21 20500 20501 20502 20503 20504 20505 20506 20507 20508 20509 20510 20511 7086 8086
22 20520 20521 20522 20523 20524 20525 20526 20527 20528 20529 20530 20531 7087 8087
23 20540 20541 20542 20543 20544 20545 20546 20547 20548 20549 20550 20551 7088 8088
24 20560 20561 20562 20563 20564 20565 20566 20567 20568 20569 20570 20571 7089 8089
25 20580 20581 20582 20583 20584 20585 20586 20587 20588 20589 20590 20591 7090 8090
26 20600 20601 20602 20603 20604 20605 20606 20607 20608 20609 20610 20611 7091 8091
27 20620 20621 20622 20623 20624 20625 20626 20627 20628 20629 20630 20631 7092 8092
28 20640 20641 20642 20643 20644 20645 20646 20647 20648 20649 20650 20651 7093 8093
29 20660 20661 20662 20663 20664 20665 20666 20667 20668 20669 20670 20671 7094 8094
30 20680 20681 20682 20683 20684 20685 20686 20687 20688 20689 20690 20691 7095 8095
31 20700 20701 20702 20703 20704 20705 20706 20707 20708 20709 20710 20711 7096 8096
32 20720 20721 20722 20723 20724 20725 20726 20727 20728 20729 20730 20731 7097 8097
33 20740 20741 20742 20743 20744 20745 20746 20747 20748 20749 20750 20751 7098 8098
34 20760 20761 20762 20763 20764 20765 20766 20767 20768 20769 20770 20771 7099 8099
35 20780 20781 20782 20783 20784 20785 20786 20787 20788 20789 20790 20791 7100 8100
36 20800 20801 20802 20803 20804 20805 20806 20807 20808 20809 20810 20811 7101 8101
37 20820 20821 20822 20823 20824 20825 20826 20827 20828 20829 20830 20831 7102 8102
38 20840 20841 20842 20843 20844 20845 20846 20847 20848 20849 20850 20851 7103 8103
39 20860 20861 20862 20863 20864 20865 20866 20867 20868 20869 20870 20871 7104 8104
40 20880 20881 20882 20883 20884 20885 20886 20887 20888 20889 20890 20891 7105 8105
41 20900 20901 20902 20903 20904 20905 20906 20907 20908 20909 20910 20911 7106 8106
42 20920 20921 20922 20923 20924 20925 20926 20927 20928 20929 20930 20931 7107 8107
43 20940 20941 20942 20943 20944 20945 20946 20947 20948 20949 20950 20951 7108 8108
44 20960 20961 20962 20963 20964 20965 20966 20967 20968 20969 20970 20971 7109 8109
45 20980 20981 20982 20983 20984 20985 20986 20987 20988 20989 20990 20991 7110 8110
46 21000 21001 21002 21003 21004 21005 21006 21007 21008 21009 21010 21011 7111 8111
47 21020 21021 21022 21023 21024 21025 21026 21027 21028 21029 21030 21031 7112 8112
48 21040 21041 21042 21043 21044 21045 21046 21047 21048 21049 21050 21051 7113 8113
49 21060 21061 21062 21063 21064 21065 21066 21067 21068 21069 21070 21071 7114 8114
50 21080 21081 21082 21083 21084 21085 21086 21087 21088 21089 21090 21091 7115 8115

Trip/Odometer

Trip Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11800 Uint8 0 0 3 0 – Disable Priority
1 – Low Priority
2 – High Priority
3 – Panic Priority
11801 Uint8 1 0 1 0 – Disable Eventual records
1 – Enable
11802 Uint8 0 0 1 0 – Continuous Mode
1 – Between Records
11803 Uint16 5 0 255 km/h Start Speed
11804 Uint16 60 0 65535 Seconds Movement OFF Timeout
7031 Uint64 "" 0 10 Predefined Number Send SMS to
8031 String Trip 0 160 Text SMS text

Odometer

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11806 Uint8 0 0 1 0 – GNSS Calculation Source
1 – CAN
11807 Uint16 0 0 4294967 Kilometers Odometer Value

Template:SAS device Parameter list - Bluetooth® Template:SAS device Parameter list - Bluetooth® 4.0

Beacon List

Beacon Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
134 Uint16 0 0 2 0 - Disabled Beacon Detection
1 - All
2 - Configured
136 Uint16 0 0 1 0 - Eventual Beacon Record
1 - Periodic

Beacon List

Parameter ID Default value Beacons Parameter name
IBeacon EddyStone
1600-1624 "" UUID:Major:Minor Namespace:Instance ID Beacon ID

User Interface

GSM Indication

Parameter ID Parameter Type Default value Value range Value Parameter name Indication
Min Max
14000 Uint16 1 0 1 0 - Disable Indication Scenario GSM Error
1 - Enable
14002 Uint16 0 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14003 Uint16 0 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14001 Uint16 0 0 1 0 - Disable Enable in Sleep
1 - Enable
14004 Uint8 500 0 3600000 Miliseconds Period
14005 Uint8 500 0 10000 Miliseconds On
14006 Uint8 0 0 10000 Miliseconds Off
14007 Uint8 0 0 100 Value Repeat
14010 Uint16 0 0 1 0 - Disable Indication Scenario GSM Signal Established
1 - Enable
14012 Uint16 2 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14013 Uint16 0 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14011 Uint16 0 0 1 0 - Disable Enable in Sleep
1 - Enable
14015 Uint8 500 0 10000 Miliseconds On
14016 Uint8 500 0 10000 Miliseconds Off
14017 Uint8 1 0 100 Value Repeat
14020 Uint16 0 0 1 0 - Disable Indication Scenario SMS Send/Receive
1 - Enable
14022 Uint16 2 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14023 Uint16 1 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14021 Uint16 0 0 1 0 - Disable Enable in Sleep
1 - Enable
14025 Uint8 100 0 10000 Miliseconds On
14026 Uint8 100 0 10000 Miliseconds Off
14027 Uint8 3 0 100 Value Repeat
14030 Uint16 0 0 1 0 - Disable Indication Scenario Incoming Call
1 - Enable
14032 Uint16 3 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14033 Uint16 1 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14031 Uint16 0 0 1 0 - Disable Enable in Sleep
1 - Enable
14034 Uint8 0 0 3600000 Miliseconds Period
14035 Uint8 100 0 10000 Miliseconds On
14036 Uint8 100 0 10000 Miliseconds Off
14037 Uint8 3 0 100 Value Repeat
14310 Uint16 1 0 1 0 - Disable Indication Scenario Call Active
1 - Enable
14312 Uint16 3 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14311 Uint16 1 0 1 0 - Disable Enable in Sleep
1 - Enable
14314 Uint8 0 0 3600000 Miliseconds Period
14315 Uint8 500 0 10000 Miliseconds On
14316 Uint8 200 50 10000 Miliseconds Off
14317 Uint8 0 0 100 Value Repeat
14240 Uint16 1 0 1 0 - Disable Indication Scenario Outgoing Call
1 - Enable
14242 Uint16 0 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14243 Uint16 0 0 3} 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14241 Uint16 0 0 1 0 - Disable Enable in Sleep
1 - Enable
14244 Uint8 200 0 3600000 Miliseconds Period
14245 Uint8 200 0 10000 Miliseconds On
14246 Uint8 200 0 10000 Miliseconds Off
14247 Uint8 1 0 100 Value Repeat
14040 Uint16 0 0 1 0 - Disable Indication Scenario Remote Connection
1 - Enable
14042 Uint16 2 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14043 Uint16 0 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14041 Uint16 0 0 1 0 - Disable Enable in Sleep
1 - Enable
14044 Uint8 2000 0 3600000 Miliseconds Period
14045 Uint8 100 0 1000 Miliseconds On
14046 Uint8 100 0 1000 Miliseconds Off
14047 Uint8 3 0 100 Value Repeat

GNSS Indication

Parameter ID Parameter Type Default value Value range Value Parameter name Indication
Min Max
14070 Uint16 1 0 1 0 - Disable Indication Scenario No GPS Fix
1 - Enable
14072 Uint16 1 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14073 Uint16 0 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14074 Uint8 500 0 3600000 Miliseconds Period
14075 Uint8 500 0 1000 Miliseconds On
14076 Uint8 0 0 1000 Miliseconds Off
14077 Uint8 0 0 100 Value Repeat
14080 Uint16 1 0 1 0 - Disable Indication Scenario GPS Fix
1 - Enable
14082 Uint16 1 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14083 Uint16 0 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14084 Uint8 2000 0 3600000 Miliseconds Period
14085 Uint8 100 0 1000 Miliseconds On
14086 Uint8 100 0 1000 Miliseconds Off
14087 Uint8 3 0 100 Value Repeat

Event Indication

Parameter ID Parameter Type Default value Value range Value Parameter name Indication
Min Max
14050 Uint16 0 0 1 0 - Disable Indication Scenario Event
1 - Enable
14052 Uint16 1 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14053 Uint16 0} 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14051 Uint16 0 0 1 0 - Disable Enable in Sleep
1 - Enable
14055 Uint8 1000 0 10000 Miliseconds On
14056 Uint8 0 0 10000 Miliseconds Off
14057 Uint8 0 0 100 Value Repeat
14060 Uint16 0 0 1 0 - Disable Indication Scenario Panic Event
1 - Enable
14062 Uint16 0 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14063 Uint16 0 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14061 Uint16 0 0 1 0 - Disable Enable in Sleep
1 - Enable
14065 Uint8 1000 0 10000 Miliseconds On
14066 Uint8 2000 0 10000 Miliseconds Off
14067 Uint8 2 0 100 Value Repeat
14090 Uint16 1 0 1 0 - Disable Indication Scenario Device Off
1 - Enable
14092 Uint16 0 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14093 Uint16 1 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14095 Uint8 2000 0 10000 Miliseconds On
14096 Uint8 0 0 10000 Miliseconds Off
14097 Uint8 0 0 100 Value Repeat
14100 Uint16 1 0 1 0 - Disable Indication Scenario Device On
1 - Enable
14102 Uint16 1 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14103 Uint16 1 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14105 Uint8 2000 0 10000 Miliseconds On
14106 Uint8 0 0 10000 Miliseconds Off
14107 Uint8 0 0 100 Value Repeat
14170 Uint16 0 0 1 0 - Disable Indication Scenario Pre-Alarm
1 - Enable
14172 Uint16 0 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14173 Uint16 1 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14171 Uint16 1 0 1 0 - Disable Enable in Sleep
1 - Enable
14174 Uint8 2000 0 3600000 Miliseconds Period
14175 Uint8 500 0 10000 Miliseconds On
14176 Uint8 0 0 10000 Miliseconds Off
14177 Uint8 0 0 100 Value Repeat
14320 Uint16 1 0 1 0 - Disable Indication Scenario ManDown
1 - Enable
14322 Uint16 3 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14323 Uint16 0 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14321 Uint16 1 0 1 0 - Disable Enable in Sleep
1 - Enable
14324 Uint8 0 0 3600000 Miliseconds Period
14325 Uint8 0 0 10000 Miliseconds On
14326 Uint8 0 0 10000 Miliseconds Off
14327 Uint8 0 0 100 Value Repeat
14190 Uint16 1 0 1 0 - Disable Indication Scenario I am Alive
1 - Enable
14192 Uint16 5 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14193 Uint16 0 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14191 Uint16 0 0 1 0 - Disable Enable in Sleep
1 - Enable
14194 Uint8 60000 0 3600000 Miliseconds Period
14195 Uint8 500 0 10000 Miliseconds On
14196 Uint8 0 0 10000 Miliseconds Off
14197 Uint8 0 0 100 Value Repeat
14180 Uint16 0 0 1 0 - Disable Indication Scenario Sleep Mode
1 - Enable
14182 Uint16 1 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14183 Uint16 0 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14184 Uint8 60000 0 3600000 Miliseconds Period
14185 Uint8 2000 0 10000 Miliseconds On
14186 Uint8 0 0 10000 Miliseconds Off
14187 Uint8 0 0 100 Value Repeat
14470 Uint16 1 0 1 0 - Disable Indication Scenario No Movement Pre Alarm
1 - Enable
14472 Uint16 5 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14473 Uint16 1 0 1 0 - Audio-Off Additional Indication
1 - Audio-On
14471 Uint16 1 0 1 0 - Disable Enable in Sleep
1 - Enable
14474 Uint8 2000 0 3600000 Miliseconds Period
14475 Uint8 500 50 10000 Miliseconds On
14476 Uint8 500 0 10000 Miliseconds Off
14477 Uint8 1 0 100 Value Repeat
14480 Uint16 1 0 1 0 - Disable Indication Scenario Amber Active
1 - Enable
14482 Uint16 3 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14483 Uint16 0 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14481 Uint16 1 0 1 0 - Disable Enable in Sleep
1 - Enable
14484 Uint8 2000 0 3600000 Miliseconds Period
14485 Uint8 500 0 10000 Miliseconds On
14486 Uint8 0 0 10000 Miliseconds Off
14487 Uint8 0 0 100 Value Repeat
14490 Uint16 1 0 1 0 - Disable Indication Scenario Amber Pre-Alarm
1 - Enable
14492 Uint16 3 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14493 Uint16 1 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14491 Uint16 1 0 1 0 - Disable Enable in Sleep
1 - Enable
14494 Uint8 0 0 3600000 Miliseconds Period
14495 Uint8 200 0 10000 Miliseconds On
14496 Uint8 100 0 10000 Miliseconds Off
14497 Uint8 0 0 100 Value Repeat
14500 Uint16 1 0 1 0 - Disable Indication Scenario Amber Alarm
1 - Enable
14502 Uint16 2 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14503 Uint16 3 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14501 Uint16 1 0 1 0 - Disable Enable in Sleep
1 - Enable
14504 Uint8 0 0 3600000 Miliseconds Period
14505 Uint8 200 0 10000 Miliseconds On
14506 Uint8 100 0 10000 Miliseconds Off
14507 Uint8 0 0 100 Value Repeat

Battery Indication

Parameter ID Parameter Type Default value Value range Value Parameter name Indication
Min Max
14150 Uint16 1 0 1 0 - Disable Indication Scenario Charging
1 - Enable
14152 Uint16 1 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14153 Uint16 0 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14154 Uint8 2000 0 3600000 Miliseconds Period
14155 Uint8 200 0 10000 Miliseconds On
14156 Uint8 200 0 10000 Miliseconds Off
14157 Uint8 1 0 100 Value Repeat
14160 Uint16 1 0 1 0 - Disable Indication Scenario Fully Charged
1 - Enable
14162 Uint16 1 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14163 Uint16 0 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14164 Uint8 0 0 3600000 Miliseconds Period
14165 Uint8 0 0 10000 Miliseconds On
14166 Uint8 0 0 10000 Miliseconds Off
14167 Uint8 0 0 100 Value Repeat
14230 Uint16 1 0 1 0 - Disable Indication Scenario Charger Error
1 - Enable
14232 Uint16 0 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14233 Uint16 1 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14231 Uint16 1 0 1 0 - Disable Enable in Sleep
1 - Enable
14234 Uint8 2000 0 3600000 Miliseconds Period
14235 Uint8 200 0 10000 Miliseconds On
14236 Uint8 200 0 10000 Miliseconds Off
14237 Uint8 1 0 100 Value Repeat
14220 Uint16 1 0 1 0 - Disable Indication Scenario Battery Low
1 - Enable
14222 Uint16 0 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14223 Uint16 1 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14224 Uint8 2000 0 3600000 Miliseconds Period
14225 Uint8 100 0 10000 Miliseconds On
14226 Uint8 100 0 10000 Miliseconds Off
14227 Uint8 3 0 100 Value Repeat
12990 Uint8 10 0 100 Percentage Battery Level

Keyboard Indication

Parameter ID Parameter Type Default value Value range Value Parameter name Indication
Min Max
14110 Uint16 0 0 1 0 - Disable Indication Scenario Alarm Key Pressed
1 - Enable
14112 Uint16 1 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14113 Uint16 0 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14114 Uint8 00 0 3600000 Miliseconds Period
14115 Uint8 0 0 10000 Miliseconds On
14116 Uint8 0 0 10000 Miliseconds Off
14117 Uint8 0 0 100 Value Repeat
14130 Uint16 0 0 1 0 - Disable Indication Scenario Alarm Key Action Activated
1 - Enable
14132 Uint16 3 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14133 Uint16 1 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14131 Uint16 1 0 1 0 - Disable Enable in Sleep
1 - Enable
14135 Uint8 300 0 10000 Miliseconds On
14136 Uint8 0 0 10000 Miliseconds Off
14137 Uint8 0 0 100 Value Repeat
14140 Uint16 0 0 1 0 - Disable Indication Scenario Alarm Key Action Deactivated
1 - Enable
14142 Uint16 3 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14143 Uint16 1 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14141 Uint16 1 0 1 0 - Disable Enable in Sleep
1 - Enable
14145 Uint8 200 0 10000 Miliseconds On
14146 Uint8 0 0 10000 Miliseconds Off
14147 Uint8 1 0 100 Value Repeat
14120 Uint16 0 0 1 0 - Disable Indication Scenario Power Key Pressed
1 - Enable
14122 Uint16 1 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14123 Uint16 0 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14124 Uint8 0 0 3600000 Miliseconds Period
14125 Uint8 0 0 10000 Miliseconds On
14126 Uint8 0 0 10000 Miliseconds Off
14127 Uint8 0 0 100 Value Repeat
14360 Uint16 0 0 1 0 - Disable Indication Scenario Power Key Action Activated
1 - Enable
14362 Uint16 3 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14363 Uint16 1 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14361 Uint16 1 0 1 0 - Disable Enable in Sleep
1 - Enable
14365 Uint8 300 0 10000 Miliseconds On
14366 Uint8 0 0 10000 Miliseconds Off
14367 Uint8 0 0 100 Value Repeat
14370 Uint16 0 0 1 0 - Disable Indication Scenario Power Key Action Deactivated
1 - Enable
14372 Uint16 3 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14373 Uint16 1 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14371 Uint16 1 0 1 0 - Disable Enable in Sleep
1 - Enable
14375 Uint8 200 0 10000 Miliseconds On
14376 Uint8 0 0 10000 Miliseconds Off
14377 Uint8 1 0 100 Value Repeat
14380 Uint16 1 0 1 0 - Disable Indication Scenario Key 1 Pressed
1 - Enable
14382 Uint16 5 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14383 Uint16 0 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14387 Uint8 0 0 100 Value Repeat
14390 Uint16 0 0 1 0 - Disable Indication Scenario Key 1 Action Activated
1 - Enable
14392 Uint16 5 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14393 Uint16 3 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14391 Uint16 0 0 1 0 - Disable Enable in Sleep
1 - Enable
14397 Uint8 0 0 100 Value Repeat
14400 Uint16 0 0 1 0 - Disable Indication Scenario Key 1 Action Deactivated
1 - Enable
14402 Uint16 5 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14403 Uint16 3 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14401 Uint16 0 0 1 0 - Disable Enable in Sleep
1 - Enable
14407 Uint8 1 0 100 Value Repeat
14410 Uint16 1 0 1 0 - Disable Indication Scenario Key 2 pressed
1 - Enable
14412 Uint16 5 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14413 Uint16 0 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14417 Uint8 0 0 100 Value Repeat
14420 Uint16 0 0 1 0 - Disable Indication Scenario Key 2 Action Activated
1 - Enable
14422 Uint16 5 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14423 Uint16 3 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14421 Uint16 0 0 1 0 - Disable Enable in Sleep
1 - Enable
14427 Uint8 0 0 100 Value Repeat
14430 Uint16 0 0 1 0 - Disable Indication Scenario Key 2 Action Deactivated
1 - Enable
14432 Uint16 5 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14433 Uint16 3 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14431 Uint16 0 0 1 0 - Disable Enable in Sleep
1 - Enable
14437 Uint8 1 0 100 Value Repeat
14440 Uint16 1 0 1 0 - Disable Indication Scenario Key 3 pressed
1 - Enable
14442 Uint16 5 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14443 Uint16 0 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14447 Uint8 0 0 100 Value Repeat
14450 Uint16 0 0 1 0 - Disable Indication Scenario Key 3 Action Activated
1 - Enable
14452 Uint16 5 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14453 Uint16 3 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14451 Uint16 0 0 1 0 - Disable Enable in Sleep
1 - Enable
14457 Uint8 0 0 100 Value Repeat
14460 Uint16 0 0 1 0 - Disable Indication Scenario Key 3 Action Deactivated
1 - Enable
14462 Uint16 5 0 6 0 - Battery Red LED
1 - Battery Green
2 - GSM Red
3 - GSM Green
4 - GNSS Red
5 - GNSS Green
6 - None
14463 Uint16 3 0 3 0 - Vibration and Audio off Additional Indication
1 - Only Vibration on
2 - Only Audio on
3 - Vibration and Audio on
14461 Uint16 0 0 1 0 - Disable Enable in Sleep
1 - Enable
14467 Uint8 1 0 100 Value Repeat

Keyboard

Button IO feature

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13048 Uint16 1 1 2 1 - Low Priority Feature settings
2 - High Priority
13049 Uint16 0 0 31 0 - None Feature settings
1 - Alarm
2 - Power
3 - Power + Alarm
4 - Button 1
5 - Button 1 + Alarm
6 - Button 1 + Power
7 - Button 1 + Power + Alarm
8 - Button 2
9 - Button 2 + Alarm
10 - Button 2 + Power
11 - Button 2 + Alarm+Power
12 - Button 2 + Button 1
13 - Button 2 + Button 1 + Alarm
14 - Button 2 + Button 1 + Power
15 - Button 2 + Button 1 + Alarm + Power
16 - Button 3
17 - Button 3 + Alarm
18 - Button 3 + Power
19 - Button 3 + Button 1
20 - Button 3 + Button 1 + Alarm
21 - Button 3 + Button 1 + Power
22 - Button 3 + Button 1 + Alarm + Power
23 - Button 3 + Button 2
24 - Button 3 + Button 2
25 - Button 3 + Button 2 + Alarm
26 - Button 3 + Button 2 + Power
27 - Button 3 + Button 2 + Alarm + Power
28 - Button 3 + Button 2 + Button 1
29 - Button 3 + Button 2 + Button 1 + Alarm
30 - Button 3 + Button 2 + Button 1 + Power
31 - Button 3 + Button 2 + Button 1 + Alarm + Power

Power Off Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13087 Uint16 1 0 1 0 - Disable Power Off With Power Key
1 - Enable

Power Button

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13014 Uint16 18 0 26 0 - None 1 Click
1 - Alarm
2 - Man-Down ON
3 - Man-Down OFF
4 - Man-Down Switch
5 - Auto Geofencing ON
6 - Auto Geofencing OFF
7 - Auto Geofencing Switch
8 - Call
9 - SMS
10 - Tracking Switch
11 - Tracking ON
12 - Tracking OFF
13 - Movement Event Switch
14 - Movement Event ON
15 - Movement Event OFF
16 - Answer
17 - Load Answer
18 - Hung-Up
20 - Volume Up
21 - Volume Down
22 - Switch Speaker
23 - Power Off
24 - Function Pause
25 - Amber Alert ON
26 - Amber Alert OFF
27 - Amber Alert Switch
28 - ManDown Cancel
29 - On Demand Tracking ON
30 - On Demand Tracking OFF
31 - On Demand Tracking Switch
32 - Beacon On Demand ON
33 - Beacon On Demand OFF
34 - Beacon On Demand Switch
13034 Uint16 0 0 10 Predefined Number Call to
(If action Call or Function Pause is selected)
7298 Uint16 0 0 10 Predefined Number Send SMS to
(If action SMS or Function Pause is selected)
8298 Uint16 Power Button 0 16 String SMS Text
(If action SMS or Function Pause isselected)
13015 Uint16 0 0 26 0 - None 2 Clicks
1 - Alarm
2 - Man-Down ON
3 - Man-Down OFF
4 - Man-Down Switch
5 - Auto Geofencing ON
6 - Auto Geofencing OFF
7 - Auto Geofencing Switch
8 - Call
9 - SMS
10 - Tracking Switch
11 - Tracking ON
12 - Tracking OFF
13 - Movement Event Switch
14 - Movement Event ON
15 - Movement Event OFF
16 - Answer
17 - Load Answer
18 - Hung-Up
19 - Volume up
20 - Volume down
21 - Switch Speaker
22 - Power Off
23 - Function Pause
24 - Amber Alert On
25 - Amber Alert Off
26 - Amber Alert Switch
13035 Uint16 0 0 10 Predefined Number Call to
(If action Call or Function Pause is selected)
7299 Uint16 0 0 10 Predefined Number Send SMS to
(If action SMS or Function Pause is selected)
8299 Uint16 Power Button 0 16 String SMS Text
(If action SMS or Function Pause isselected)
13016 Uint16 19 0 26 0 - None Long Click
1 - Alarm
2 - Man-Down ON
3 - Man-Down OFF
4 - Man-Down Switch
5 - Auto Geofencing ON
6 - Auto Geofencing OFF
7 - Auto Geofencing Switch
8 - Call
9 - SMS
10 - Tracking Switch
11 - Tracking ON
12 - Tracking OFF
13 - Movement Event Switch
14 - Movement Event ON
15 - Movement Event OFF
16 - Answer
17 - Load Answer
18 - Hung-Up
19 - Volume up
20 - Volume down
21 - Switch Speaker
22 - Power Off
23 - Function Pause
24 - Amber Alert On
25 - Amber Alert Off
26 - Amber Alert Switch
13036 Uint16 0 0 10 Predefined Number Call to
(If action Call or Function Pause is selected)
7300 Uint16 0 0 10 Predefined Number Send SMS to
(If action SMS or Function Pause is selected)
8300 Uint16 Power Button 0 16 String SMS Text
(If action SMS or Function Pause isselected)

Alarm Button

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13011 Uint16 1 0 26 0 - None 1 Click
1 - Alarm
2 - Man-Down ON
3 - Man-Down OFF
4 - Man-Down Switch
5 - Auto Geofencing ON
6 - Auto Geofencing OFF
7 - Auto Geofencing Switch
8 - Call
9 - SMS
10 - Tracking Switch
11 - Tracking ON
12 - Tracking OFF
13 - Movement Event Switch
14 - Movement Event ON
15 - Movement Event OFF
16 - Answer
17 - Load Answer
18 - Hung-Up
19 - Volume up
20 - Volume down
21 - Switch Speaker
22 - Power Off
23 - Function Pause
24 - Amber Alert On
25 - Amber Alert Off
26 - Amber Alert Switch
13031 Uint16 0 0 10 Predefined Number Call to
(If action Call or Function Pause is selected)
7295 Uint16 0 0 10 Predefined Number Send SMS to
(If action SMS or Function Pause is selected)
8295 Uint16 Alarm Button 0 16 String SMS Text
(If action SMS or Function Pause isselected)
13012 Uint16 8 0 26 0 - None 2 Clicks
1 - Alarm
2 - Man-Down ON
3 - Man-Down OFF
4 - Man-Down Switch
5 - Auto Geofencing ON
6 - Auto Geofencing OFF
7 - Auto Geofencing Switch
8 - Call
9 - SMS
10 - Tracking Switch
11 - Tracking ON
12 - Tracking OFF
13 - Movement Event Switch
14 - Movement Event ON
15 - Movement Event OFF
16 - Answer
17 - Load Answer
18 - Hung-Up
19 - Volume up
20 - Volume down
21 - Switch Speaker
22 - Power Off
23 - Function Pause
24 - Amber Alert On
25 - Amber Alert Off
26 - Amber Alert Switch
13032 Uint16 0 0 10 Predefined Number Call to
(If action Call or Function Pause is selected)
7296 Uint16 0 0 10 Predefined Number Send SMS to
(If action SMS or Function Pause is selected)
8296 Uint16 Alarm Button 0 16 String SMS Text
(If action SMS or Function Pause isselected)
13013 Uint16 0 0 26 0 - None Long Click
1 - Alarm
2 - Man-Down ON
3 - Man-Down OFF
4 - Man-Down Switch
5 - Auto Geofencing ON
6 - Auto Geofencing OFF
7 - Auto Geofencing Switch
8 - Call
9 - SMS
10 - Tracking Switch
11 - Tracking ON
12 - Tracking OFF
13 - Movement Event Switch
14 - Movement Event ON
15 - Movement Event OFF
16 - Answer
17 - Load Answer
18 - Hung-Up
19 - Volume up
20 - Volume down
21 - Switch Speaker
22 - Power Off
23 - Function Pause
24 - Amber Alert On
25 - Amber Alert Off
26 - Amber Alert Switch
13033 Uint16 0 0 10 Predefined Number Call to
(If action Call or Function Pause is selected)
7297 Uint16 0 0 10 Predefined Number Send SMS to
(If action SMS or Function Pause is selected)
8297 Uint16 Alarm Button 0 16 String SMS Text
(If action SMS or Function Pause isselected)

Button 1

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13017 Uint16 11 0 26 0 - None 1 Click
1 - Alarm
2 - Man-Down ON
3 - Man-Down OFF
4 - Man-Down Switch
5 - Auto Geofencing ON
6 - Auto Geofencing OFF
7 - Auto Geofencing Switch
8 - Call
9 - SMS
10 - Tracking Switch
11 - Tracking ON
12 - Tracking OFF
13 - Movement Event Switch
14 - Movement Event ON
15 - Movement Event OFF
16 - Answer
17 - Load Answer
18 - Hung-Up
19 - Volume up
20 - Volume down
21 - Switch Speaker
22 - Power Off
23 - Function Pause
24 - Amber Alert On
25 - Amber Alert Off
26 - Amber Alert Switch
13037 Uint16 0 0 10 Predefined Number Call to
(If action Call or Function Pause is selected)
7301 Uint16 0 0 10 Predefined Number Send SMS to
(If action SMS or Function Pause is selected)
8301 Uint16 Button 1 0 16 String SMS Text
(If action SMS or Function Pause isselected)
13018 Uint16 12 0 26 0 - None 2 Clicks
1 - Alarm
2 - Man-Down ON
3 - Man-Down OFF
4 - Man-Down Switch
5 - Auto Geofencing ON
6 - Auto Geofencing OFF
7 - Auto Geofencing Switch
8 - Call
9 - SMS
10 - Tracking Switch
11 - Tracking ON
12 - Tracking OFF
13 - Movement Event Switch
14 - Movement Event ON
15 - Movement Event OFF
16 - Answer
17 - Load Answer
18 - Hung-Up
19 - Volume up
20 - Volume down
21 - Switch Speaker
22 - Power Off
23 - Function Pause
24 - Amber Alert On
25 - Amber Alert Off
26 - Amber Alert Switch
13038 Uint16 0 0 10 Predefined Number Call to
(If action Call or Function Pause is selected)
7302 Uint16 0 0 10 Predefined Number Send SMS to
(If action SMS or Function Pause is selected)
8302 Uint16 Button 1 0 16 String SMS Text
(If action SMS or Function Pause isselected)
13019 Uint16 10 0 26 0 - None Long Click
1 - Alarm
2 - Man-Down ON
3 - Man-Down OFF
4 - Man-Down Switch
5 - Auto Geofencing ON
6 - Auto Geofencing OFF
7 - Auto Geofencing Switch
8 - Call
9 - SMS
10 - Tracking Switch
11 - Tracking ON
12 - Tracking OFF
13 - Movement Event Switch
14 - Movement Event ON
15 - Movement Event OFF
16 - Answer
17 - Load Answer
18 - Hung-Up
19 - Volume up
20 - Volume down
21 - Switch Speaker
22 - Power Off
23 - Function Pause
24 - Amber Alert On
25 - Amber Alert Off
26 - Amber Alert Switch
13039 Uint16 0 0 10 Predefined Number Call to
(If action Call or Function Pause is selected)
7303 Uint16 0 0 10 Predefined Number Send SMS to
(If action SMS or Function Pause is selected)
8303 Uint16 Button 1 0 16 String SMS Text
(If action SMS or Function Pause isselected)

Button 2

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13020 Uint16 2 0 26 0 - None 1 Click
1 - Alarm
2 - Man-Down ON
3 - Man-Down OFF
4 - Man-Down Switch
5 - Auto Geofencing ON
6 - Auto Geofencing OFF
7 - Auto Geofencing Switch
8 - Call
9 - SMS
10 - Tracking Switch
11 - Tracking ON
12 - Tracking OFF
13 - Movement Event Switch
14 - Movement Event ON
15 - Movement Event OFF
16 - Answer
17 - Load Answer
18 - Hung-Up
19 - Volume up
20 - Volume down
21 - Switch Speaker
22 - Power Off
23 - Function Pause
24 - Amber Alert On
25 - Amber Alert Off
26 - Amber Alert Switch
13040 Uint16 0 0 10 Predefined Number Call to
(If action Call or Function Pause is selected)
7304 Uint16 0 0 10 Predefined Number Send SMS to
(If action SMS or Function Pause is selected)
8304 Uint16 Button 2 0 16 String SMS Text
(If action SMS or Function Pause isselected)
13021 Uint16 3 0 26 0 - None 2 Clicks
1 - Alarm
2 - Man-Down ON
3 - Man-Down OFF
4 - Man-Down Switch
5 - Auto Geofencing ON
6 - Auto Geofencing OFF
7 - Auto Geofencing Switch
8 - Call
9 - SMS
10 - Tracking Switch
11 - Tracking ON
12 - Tracking OFF
13 - Movement Event Switch
14 - Movement Event ON
15 - Movement Event OFF
16 - Answer
17 - Load Answer
18 - Hung-Up
19 - Volume up
20 - Volume down
21 - Switch Speaker
22 - Power Off
23 - Function Pause
24 - Amber Alert On
25 - Amber Alert Off
26 - Amber Alert Switch
13041 Uint16 0 0 10 Predefined Number Call to
(If action Call or Function Pause is selected)
7305 Uint16 0 0 10 Predefined Number Send SMS to
(If action SMS or Function Pause is selected)
8305 Uint16 Button 2 0 16 String SMS Text
(If action SMS or Function Pause isselected)
13022 Uint16 4 0 26 0 - None Long Click
1 - Alarm
2 - Man-Down ON
3 - Man-Down OFF
4 - Man-Down Switch
5 - Auto Geofencing ON
6 - Auto Geofencing OFF
7 - Auto Geofencing Switch
8 - Call
9 - SMS
10 - Tracking Switch
11 - Tracking ON
12 - Tracking OFF
13 - Movement Event Switch
14 - Movement Event ON
15 - Movement Event OFF
16 - Answer
17 - Load Answer
18 - Hung-Up
19 - Volume up
20 - Volume down
21 - Switch Speaker
22 - Power Off
23 - Function Pause
24 - Amber Alert On
25 - Amber Alert Off
26 - Amber Alert Switch
13042 Uint16 0 0 10 Predefined Number Call to
(If action Call or Function Pause is selected)
7306 Uint16 0 0 10 Predefined Number Send SMS to
(If action SMS or Function Pause is selected)
8306 Uint16 Button 2 0 16 String SMS Text
(If action SMS or Function Pause isselected)

Button 3

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13023 Uint16 16 0 26 0 - None 1 Click
1 - Alarm
2 - Man-Down ON
3 - Man-Down OFF
4 - Man-Down Switch
5 - Auto Geofencing ON
6 - Auto Geofencing OFF
7 - Auto Geofencing Switch
8 - Call
9 - SMS
10 - Tracking Switch
11 - Tracking ON
12 - Tracking OFF
13 - Movement Event Switch
14 - Movement Event ON
15 - Movement Event OFF
16 - Answer
17 - Load Answer
18 - Hung-Up
19 - Volume up
20 - Volume down
21 - Switch Speaker
22 - Power Off
23 - Function Pause
24 - Amber Alert On
25 - Amber Alert Off
26 - Amber Alert Switch
13043 Uint16 0 0 10 Predefined Number Call to
(If action Call or Function Pause is selected)
7307 Uint16 0 0 10 Predefined Number Send SMS to
(If action SMS or Function Pause is selected)
8307 Uint16 Button 3 0 16 String SMS Text
(If action SMS or Function Pause isselected)
13024 Uint16 21 0 26 0 - None 2 Clicks
1 - Alarm
2 - Man-Down ON
3 - Man-Down OFF
4 - Man-Down Switch
5 - Auto Geofencing ON
6 - Auto Geofencing OFF
7 - Auto Geofencing Switch
8 - Call
9 - SMS
10 - Tracking Switch
11 - Tracking ON
12 - Tracking OFF
13 - Movement Event Switch
14 - Movement Event ON
15 - Movement Event OFF
16 - Answer
17 - Load Answer
18 - Hung-Up
19 - Volume up
20 - Volume down
21 - Switch Speaker
22 - Power Off
23 - Function Pause
24 - Amber Alert On
25 - Amber Alert Off
26 - Amber Alert Switch
13044 Uint16 0 0 10 Predefined Number Call to
(If action Call or Function Pause is selected)
7308 Uint16 0 0 10 Predefined Number Send SMS to
(If action SMS or Function Pause is selected)
8308 Uint16 Button 3 0 16 String SMS Text
(If action SMS or Function Pause isselected)
13025 Uint16 0 0 26 0 - None Long Click
1 - Alarm
2 - Man-Down ON
3 - Man-Down OFF
4 - Man-Down Switch
5 - Auto Geofencing ON
6 - Auto Geofencing OFF
7 - Auto Geofencing Switch
8 - Call
9 - SMS
10 - Tracking Switch
11 - Tracking ON
12 - Tracking OFF
13 - Movement Event Switch
14 - Movement Event ON
15 - Movement Event OFF
16 - Answer
17 - Load Answer
18 - Hung-Up
19 - Volume up
20 - Volume down
21 - Switch Speaker
22 - Power Off
23 - Function Pause
24 - Amber Alert On
25 - Amber Alert Off
26 - Amber Alert Switch
13045 Uint16 0 0 10 Predefined Number Call to
(If action Call or Function Pause is selected)
7309 Uint16 0 0 10 Predefined Number Send SMS to
(If action SMS or Function Pause is selected)
8309 Uint16 Button 3 0 16 String SMS Text
(If action SMS or Function Pause isselected)

I/O

Parameter ID Parameter Type Default value Value range Value parameter Input Name
Min Max
50000 Uint8 1 0 3 0 – None Priority Ignition
1 – Low
2 – High
3 – Panic
50003 Uint8 0 0 0 - Low Level
50002 Uint8 0 0 1 - High Level
50004 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50001 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50005 Uint16 10 0 65535 - Average Const
7000 Uint8 0 0 10 Predefined Number Send SMS To
8000 String Ignition 0 160 Predefined Number SMS Text
50010 Uint8 1 0 3 0 – None Priority Movement
1 – Low
2 – High
3 – Panic
50013 Uint8 0 0 0 - Low Level
50012 Uint8 0 0 1 - High Level
50014 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50011 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50015 Uint16 10 0 65535 - Average Const
7001 Uint8 0 0 10 Predefined Number Send SMS To
8001 String Movement 0 160 Predefined Number SMS Text
50020 Uint8 1 0 3 0 – None Priority Data Mode
1 – Low
2 – High
3 – Panic
50023 Uint8 0 0 0 - Low Level
50022 Uint8 0 0 5 - High Level
50024 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50021 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7002 Uint8 0 0 10 Predefined Number Send SMS To
8002 String Data Mode 0 160 Predefined Number SMS Text
50030 Uint8 1 0 3 0 – None Priority GSM Signal
1 – Low
2 – High
3 – Panic
50033 Uint8 0 0 0 - Low Level
50032 Uint8 0 0 5 - High Level
50034 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50031 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50035 Uint16 7 0 65535 - Average Const
7003 Uint8 0 0 10 Predefined Number Send SMS To
8003 String GSM Signal 0 160 Predefined Number SMS Text
50040 Uint8 1 0 3 0 – None Priority Sleep Mode
1 – Low
2 – High
3 – Panic
50043 Uint8 0 0 0 - Low Level
50042 Uint8 0 0 3 - High Level
50044 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50041 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7004 Uint8 0 0 10 Predefined Number Send SMS To
8004 Uint8 Sleep mode 0 160 Predefined Number SMS Text
50050 Uint8 1 0 3 0 – None Priority GNSS Status
1 – Low
2 – High
3 – Panic
50053 Uint8 0 0 0 - Low Level
50052 Uint8 0 0 5 - High Level
50054 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50051 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7005 Uint8 0 0 10 Predefined Number Send SMS To
8005 String GNSS Power 0 160 Predefined Number SMS Text
50060 Uint8 1 0 3 0 – None Priority GNSS PDOP
1 – Low
2 – High
3 – Panic
50063 Uint8 0 0 0 - Low Level
50062 Uint8 0 0 1000 - High Level
50064 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50061 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50065 Uint16 10 0 65535 - Average Const
7006 Uint8 0 0 10 Predefined Number Send SMS To
8006 String GNSS PDOP 0 160 Predefined Number SMS Text
50070 Uint8 1 0 3 0 – None Priority GNSS HDOP
1 – Low
2 – High
3 – Panic
50073 Uint8 0 0 0 - Low Level
50072 Uint8 0 0 1000 - High Level
50074 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50071 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50075 Uint16 10 0 65535 - Average Const
7007 Uint8 0 0 10 Predefined Number Send SMS To
8007 String GNSS HDOP 0 160 Predefined Number SMS Text
52310 Uint8 1 0 3 0 – None Priority User ID
1 – Low
2 – High
3 – Panic
52314 Uint8 0 0 1 0 – No Event Only
1 – Yes
52311 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7434 Uint8 0 0 10 Predefined Number Send SMS To
8434 String User ID 0 160 Predefined Number SMS Text
50080 Uint8 1 0 3 0 – None Priority External Voltage
1 – Low
2 – High
3 – Panic
50083 Uint8 0 0 60000 mV Low Level
50082 Uint8 0 0 60000 mV High Level
50084 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50081 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50085 Uint16 10 0 65535 - Average Const
7008 Uint8 0 0 10 Predefined Number Send SMS To
8008 String External Voltage 0 160 Predefined Number SMS Text
50090 Uint8 1 0 3 0 – None Priority Speed
1 – Low
2 – High
3 – Panic
50093 Uint8 0 0 0 Km/h Low Level
50092 Uint8 0 0 300 Km/h High Level
50094 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50091 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50095 Uint16 1 0 65535 - Average Const
7009 Uint8 0 0 10 Predefined Number Send SMS To
8009 String Speed 0 160 Predefined Number SMS Text
50100 Uint8 0 0 3 0 – None Priority GSM Cell ID
1 – Low
2 – High
3 – Panic
50103 Uint8 0 0 0 - Low Level
50102 Uint8 0 0 999999 - High Level
50104 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50101 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7010 Uint8 0 0 10 Predefined Number Send SMS To
8010 String GSM Cell ID 0 160 Predefined Number SMS Text
50110 Uint8 0 0 3 0 – None Priority GSM Area Code
1 – Low
2 – High
3 – Panic
50113 Uint8 0 0 0 - Low Level
50112 Uint8 0 0 999999 - High Level
50114 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50111 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7011 Uint8 0 0 10 Predefined Number Send SMS To
8011 String GSM Area Code 0 160 Predefined Number SMS Text
50120 Uint8 1 0 3 0 – None Priority Battery Voltage
1 – Low
2 – High
3 – Panic
50123 Uint8 0 0 5000/11000 (LiPo/NiMh) mV Low Level
50122 Uint8 0 0 5000/11000 (LiPo/NiMh) mV High Level
50124 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50121 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50125 Uint16 10 0 65535 - Average Const
7012 Uint8 0 0 10 Predefined Number Send SMS To
8012 String Battery Voltage 0 160 Predefined Number SMS Text
50130 Uint8 1 0 3 0 – None Priority Battery Current
1 – Low
2 – High
3 – Panic
50133 Uint8 0 0 0 mA Low Level
50132 Uint8 0 0 5000 mA High Level
50134 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50131 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50135 Uint16 10 0 65535 - Average Const
7013 Uint8 0 0 10 Predefined Number Send SMS To
8013 String Battery Current 0 160 Predefined Number SMS Text
50690 Uint8 1 0 3 0 – None Priority Battery level %
1 – Low
2 – High
3 – Panic
50693 Uint8 0 0 100 ‎% Low Level
50692 Uint8 0 0 100 ‎% High Level
50694 Uint8 0 0 1 0 – No Event Only
1 – Yes
50691 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7243 Uint8 0 0 10 Predefined Number Send SMS To
8243 String Battery Level % 0 160 Predefined Number SMS text
50140 Uint8 0 0 3 0 – None Priority Active GSM Operator
1 – Low
2 – High
3 – Panic
50143 Uint8 0 0 0 - Low Level
50142 Uint8 0 0 9999999 - High Level
50144 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50141 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7014 Uint8 0 0 10 Predefined Number Send SMS To
8014 String Active GSM Operator 0 160 Predefined Number SMS Text
50150 Uint8 0 0 3 0 – None Priority Trip Odometer
1 – Low
2 – High
3 – Panic
50153 Uint8 0 0 2147483646 m Low Level
50152 Uint8 0 0 2147483646 m High Level
50154 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50151 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7015 Uint8 0 0 10 Predefined Number Send SMS To
8015 String Trip Odometer 0 160 Predefined Number SMS Text
50160 Uint8 0 0 3 0 – None Priority Total Odometer
1 – Low
2 – High
3 – Panic
50163 Uint8 0 0 2147483646 m Low Level
50162 Uint8 0 0 2147483646 m High Level
50164 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50161 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7016 Uint8 0 0 10 Predefined Number Send SMS To
8016 String Total Odometer 0 160 Predefined Number SMS Text
50170 Uint8 0 0 3 0 – None Priority Digital Input 1
1 – Low
2 – High
3 – Panic
50173 Uint8 0 0 0 - Low Level
50172 Uint8 0 0 1 - High Level
50174 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50171 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50175 Uint16 10 0 65535 - Average Const
7017 Uint8 0 0 10 Predefined Number Send SMS To
8017 String Dig. Input 1 0 160 Predefined Number SMS Text
50270 Uint8 0 0 3 0 – None Priority Digital Input 2
1 – Low
2 – High
3 – Panic
50273 Uint8 0 0 0 - Low Level
50272 Uint8 0 0 1 - High Level
50274 Uint16 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50271 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50275 Uint16 1 0 65535 - Average Const
7116 Uint8 0 0 10 Predefined Number Send SMS To
8116 String Dig. Input 2 0 160 Predefined Number SMS Text
50280 Uint8 0 0 3 0 – None Priority Digital Input 3
1 – Low
2 – High
3 – Panic
50283 Uint8 0 0 0 - Low Level
50282 Uint8 0 0 1 - High Level
50284 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50281 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50285 Uint16 1 0 65535 - Average Const
7117 Uint8 0 0 10 Predefined Number Send SMS To
8117 String Dig. Input 3 0 160 Predefined Number SMS Text
50710 Uint8 0 0 3 0 – None Priority Digital Input 4
1 – Low
2 – High
3 – Panic
50713 Uint8 0 0 0 - Low Level
50712 Uint8 0 0 1 - High Level
50714 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50711 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50715 Uint16 1 0 65535 - Average Const
7249 Uint8 0 0 10 Predefined Number Send SMS To
8249 String Dig. Input 4 0 160 Predefined Number SMS Text
50190 Uint8 0 0 3 0 – None Priority Digital Output 1
1 – Low
2 – High
3 – Panic
50193 Uint8 0 0 0 - Low Level
50192 Uint8 0 0 1 - High Level
50194 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50191 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50195 Uint16 10 0 65535 - Average Const
7019 Uint8 0 0 10 Predefined Number Send SMS To
8019 String Dig. Output 1 0 160 Predefined Number SMS Text
50300 Uint8 0 0 3 0 – None Priority Digital Output 2
1 – Low
2 – High
3 – Panic
50303 Uint8 0 0 0 - Low Level
50302 Uint8 0 0 1 - High Level
50304 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50301 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50305 Uint16 10 0 65535 - Average Const
7019 Uint8 0 0 10 Predefined Number Send SMS To
8019 String Dig. Output 2 0 160 Predefined Number SMS Text
52180 Uint8 0 0 3 0 – None Priority DOUT 1 Overcurrent
1 – Low
2 – High
3 – Panic
52183 Uint8 0 0 0 - Low Level
52182 Uint8 0 0 1 - High Level
5 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
52184 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
52185 Uint16 1 0 65535 - Average Const
7421 Uint8 0 0 10 Predefined Number Send SMS To
8421 String DOUT 1 Overcurrent 0 160 Predefined Number SMS Text
52190 Uint8 0 0 3 0 – None Priority DOUT 2 Overcurrent
1 – Low
2 – High
3 – Panic
52193 Uint8 0 0 0 - Low Level
52192 Uint8 0 0 1 - High Level
5 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
52194 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
52191 Uint16 1 0 65535 - Average Const
7422 Uint8 0 0 10 Predefined Number Send SMS To
8422 String DOUT 2 Overcurrent 0 160 Predefined Number SMS Text
50180 Uint8 0 0 3 0 – None Priority Analog Input 1
1 – Low
2 – High
3 – Panic
50183 Uint8 0 0 30000 mV Low Level
50182 Uint8 0 0 30000 mV High Level
50184 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50181 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50185 Uint16 10 0 65535 - Average Const
7018 Uint8 0 0 10 Predefined Number Send SMS To
8018 String Analog Input 1 0 160 Predefined Number SMS Text
50290 Uint8 0 0 3 0 – None Priority Analog Input 2
1 – Low
2 – High
3 – Panic
50293 Uint8 0 0 30000 mV Low Level
50292 Uint8 0 0 30000 mV High Level
50294 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50291 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50295 Uint16 10 0 65535 - Average Const
7118 Uint8 0 0 10 Predefined Number Send SMS To
8118 String Analog Input 2 0 160 Predefined Number SMS Text
52160 Uint8 0 0 3 0 – None Priority Extended Analog Input 1
1 – Low
2 – High
3 – Panic
52163 Uint8 0 0 0 - Low Level
52162 Uint8 0 0 1 - High Level
52164 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
52161 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
52165 Uint16 1 0 65535 - Average Const
7419 Uint8 0 0 10 Predefined Number Send SMS To
8419 String Analog Input 1 0 160 Predefined Number SMS Text
52170 Uint8 0 0 3 0 – None Priority Extended Analog Input 2
1 – Low
2 – High
3 – Panic
52173 Uint8 0 0 0 - Low Level
52172 Uint8 0 0 1 - High Level
52174 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
52171 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
52175 Uint16 10 0 65535 - Average Const
7420 Uint8 0 0 10 Predefined Number Send SMS To
8420 String Analog Input 2 0 160 Predefined Number SMS Text
51050 Uint8 0 0 3 0 – None Priority Instant Movement
1 – Low
2 – High
3 – Panic
51053 Uint8 0 0 0 - Low Level
51052 Uint8 0 0 1 - High Level
51054 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
51051 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
51055 Uint16 10 0 65535 - Average Const
7286 Uint8 0 0 10 Predefined Number Send SMS To
8286 String Instant Movement 0 160 Predefined Number SMS Text
50220 Uint8 0 0 3 0 – None Priority Axis X
1 – Low
2 – High
3 – Panic
50223 Uint8 0 -8000 8000 mG Low Level
50222 Uint8 0 0 8000 mG High Level
50224 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50221 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50225 Uint16 1 0 65535 - Average Const
7022 Uint8 0 0 10 Predefined Number Send SMS To
8022 String Axis X 0 160 Predefined Number SMS Text
50230 Uint8 0 0 3 0 – None Priority Axis Y
1 – Low
2 – High
3 – Panic
50233 Uint8 0 -8000 8000 mG Low Level
50232 Uint8 0 0 8000 mG High Level
50234 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50231 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50235 Uint16 1 0 65535 - Average Const
7023 Uint8 0 0 10 Predefined Number Send SMS To
8023 String Axis Y 0 160 Predefined Number SMS Text
50240 Uint8 0 0 3 0 – None Priority Axis Z
1 – Low
2 – High
3 – Panic
50243 Uint8 0 -8000 8000 mG Low Level
50242 Uint8 0 0 8000 mG High Level
50244 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50241 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50245 Uint16 1 0 65535 - Average Const
7024 Uint8 0 0 10 Predefined Number Send SMS To
8024 String Axis Z 0 160 Predefined Number SMS Text
50250 Uint8 0 0 3 0 – None Priority ICCID
1 – Low
2 – High
3 – Panic
50254 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50251 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7069 Uint8 0 0 10 Predefined Number Send SMS To
8069 String ICCID Value 0 160 Predefined Number SMS Text
50310 Uint8 0 0 3 0 – None Priority Dallas Temperature 1
1 – Low
2 – High
3 – Panic
50313 Uint8 0 0 3000 °C Low Level
50312 Uint8 0 0 3000 °C High Level
50314 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50311 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50315 Uint16 10 0 65535 - Average Const
7120 Uint8 0 0 10 Predefined Number Send SMS To
8120 String Dallas Temp. 1 0 160 Predefined Number SMS Text
50320 Uint8 0 0 3 0 – None Priority Dallas Temperature 2
1 – Low
2 – High
3 – Panic
50323 Uint8 0 0 3000 °C Low Level
50322 Uint8 0 0 3000 °C High Level
50324 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50321 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50325 Uint16 10 0 65535 - Average Const
7121 Uint8 0 0 10 Predefined Number Send SMS To
8121 String Dallas Temp. 2 0 160 Predefined Number SMS Text
50330 Uint8 0 0 3 0 – None Priority Dallas Temperature 3
1 – Low
2 – High
3 – Panic
50333 Uint8 0 0 3000 °C Low Level
50332 Uint8 0 0 3000 °C High Level
50334 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50331 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50335 Uint16 10 0 65535 - Average Const
7122 Uint8 0 0 10 Predefined Number Send SMS To
8122 String Dallas Temp. 3 0 160 Predefined Number SMS Text
50340 Uint8 0 0 3 0 – None Priority Dallas Temperature 4
1 – Low
2 – High
3 – Panic
50343 Uint8 0 0 3000 °C Low Level
50342 Uint8 0 0 3000 °C High Level
50344 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50341 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50345 Uint16 10 0 65535 - Average Const
7123 Uint8 0 0 10 Predefined Number Send SMS To
8123 String Dallas Temp. 4 0 160 Predefined Number SMS Text
50350 Uint8 0 0 3 0 – None Priority Dallas Temperature ID 1
1 – Low
2 – High
3 – Panic
50353 Uint8 0 0 999999999 - Low Level
50352 Uint8 0 0 999999999 - High Level
50354 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50351 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50355 Uint16 10 0 65535 - Average Const
7124 Uint8 0 0 10 Predefined Number Send SMS To
8124 String Dallas Temp. ID 1 0 160 Predefined Number SMS Text
50360 Uint8 0 0 3 0 – None Priority Dallas Temperature ID 2
1 – Low
2 – High
3 – Panic
50363 Uint8 0 0 999999999 - Low Level
50362 Uint8 0 0 999999999 - High Level
50364 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50361 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50365 Uint16 10 0 65535 - Average Const
7125 Uint8 0 0 10 Predefined Number Send SMS To
8125 String Dallas Temp. ID 2 0 160 Predefined Number SMS Text
50370 Uint8 0 0 3 0 – None Priority Dallas Temperature ID 3
1 – Low
2 – High
3 – Panic
50373 Uint8 0 0 999999999 - Low Level
50372 Uint8 0 0 999999999 - High Level
50374 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50371 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50375 Uint16 10 0 65535 - Average Const
7126 Uint8 0 0 10 Predefined Number Send SMS To
8126 String Dallas Temp. ID 3 0 160 Predefined Number SMS Text
50380 Uint8 0 0 3 0 – None Priority Dallas Temperature ID 4
1 – Low
2 – High
3 – Panic
50383 Uint8 0 0 999999999 - Low Level
50382 Uint8 0 0 999999999 - High Level
50384 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50381 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50385 Uint16 10 0 65535 - Average Const
7127 Uint8 0 0 10 Predefined Number Send SMS To
8127 String Dallas Temp. ID 4 0 160 Predefined Number SMS Text
50390 Uint8 0 0 3 0 – None Priority iButton
1 – Low
2 – High
3 – Panic
50393 Uint8 0 0 999999999 - Low Level
50392 Uint8 0 0 999999999 - High Level
50394 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50391 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
50395 Uint16 10 0 65535 - Average Const
7128 Uint8 0 0 10 Predefined Number Send SMS To
8128 String iButton 0 160 Predefined Number SMS Text
50510 Uint8 0 0 3 0 – None Priority Eco Score
1 – Low
2 – High
3 – Panic
50513 Uint8 0 0 999999999 - Low Level
50512 Uint8 0 0 999999999 - High Level
50514 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50511 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7220 Uint8 0 0 10 Predefined Number Send SMS To
8220 String EcoScore 0 160 Predefined Number SMS Text
51190 Uint8 0 0 3 0 – None Priority BLE 1 Custom 1
1 – Low
2 – High
3 – Panic
51193 Uint8 0 0 2147483647 ‎- Low Level
51192 Uint8 0 0 2147483647 ‎- High Level
51194 Uint8 0 0 1 0 – No Event Only
1 – Yes
51195 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7322 Uint8 0 0 10 Predefined Number Send SMS To
8322 String BLE 1 Custom 1 0 160 Predefined Number SMS Text
52480 Uint8 0 0 3 0 – None Priority BLE 1 Custom 2
1 – Low
2 – High
3 – Panic
52483 Uint8 0 0 2147483647 ‎- Low Level
52482 Uint8 0 0 2147483647 ‎- High Level
52484 Uint8 0 0 1 0 – No Event Only
1 – Yes
52481 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7323 Uint8 0 0 10 Predefined Number Send SMS To
8323 String BLE 1 Custom 2 0 160 Predefined Number SMS Text
52520 Uint8 0 0 3 0 – None Priority BLE 1 Custom 3
1 – Low
2 – High
3 – Panic
52523 Uint8 0 0 2147483647 ‎- Low Level
52522 Uint8 0 0 2147483647 ‎- High Level
52524 Uint8 0 0 1 0 – No Event Only
1 – Yes
52521 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7324 Uint8 0 0 10 Predefined Number Send SMS To
8324 String BLE 1 Custom 3 0 160 Predefined Number SMS Text
52560 Uint8 0 0 3 0 – None Priority BLE 1 Custom 4
1 – Low
2 – High
3 – Panic
52563 Uint8 0 0 2147483647 ‎- Low Level
52562 Uint8 0 0 2147483647 ‎- High Level
52564 Uint8 0 0 1 0 – No Event Only
1 – Yes
52561 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7325 Uint8 0 0 10 Predefined Number Send SMS To
8325 String BLE 1 Custom 4 0 160 Predefined Number SMS Text
52600 Uint8 0 0 3 0 – None Priority BLE 1 Custom 5
1 – Low
2 – High
3 – Panic
52603 Uint8 0 0 2147483647 ‎- Low Level
52602 Uint8 0 0 2147483647 ‎- High Level
52604 Uint8 0 0 1 0 – No Event Only
1 – Yes
52601 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7463 Uint8 0 0 10 Predefined Number Send SMS To
8463 String BLE 1 Custom 5 0 160 Predefined Number SMS Text
51200 Uint8 0 0 3 0 – None Priority BLE 2 Custom 1
1 – Low
2 – High
3 – Panic
51203 Uint8 0 0 2147483647 ‎- Low Level
51202 Uint8 0 0 2147483647 ‎- High Level
51204 Uint8 0 0 1 0 – No Event Only
1 – Yes
51201 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7451 Uint8 0 0 10 Predefined Number Send SMS To
8451 String BLE 2 Custom 1 0 160 Predefined Number SMS Text
52490 Uint8 0 0 3 0 – None Priority BLE 2 Custom 2
1 – Low
2 – High
3 – Panic
52493 Uint8 0 0 2147483647 ‎- Low Level
52492 Uint8 0 0 2147483647 ‎- High Level
52494 Uint8 0 0 1 0 – No Event Only
1 – Yes
52491 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7452 Uint8 0 0 10 Predefined Number Send SMS To
8452 String BLE 2 Custom 2 0 160 Predefined Number SMS Text
52530 Uint8 0 0 3 0 – None Priority BLE 2 Custom 3
1 – Low
2 – High
3 – Panic
52533 Uint8 0 0 2147483647 ‎- Low Level
52532 Uint8 0 0 2147483647 ‎- High Level
52534 Uint8 0 0 1 0 – No Event Only
1 – Yes
52531 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7453 Uint8 0 0 10 Predefined Number Send SMS To
8453 String BLE 2 Custom 3 0 160 Predefined Number SMS Text
52570 Uint8 0 0 3 0 – None Priority BLE 2 Custom 4
1 – Low
2 – High
3 – Panic
52573 Uint8 0 0 2147483647 ‎- Low Level
52572 Uint8 0 0 2147483647 ‎- High Level
52574 Uint8 0 0 1 0 – No Event Only
1 – Yes
52571 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7454 Uint8 0 0 10 Predefined Number Send SMS To
8454 String BLE 2 Custom 4 0 160 Predefined Number SMS Text
52610 Uint8 0 0 3 0 – None Priority BLE 2 Custom 5
1 – Low
2 – High
3 – Panic
52613 Uint8 0 0 2147483647 ‎- Low Level
52612 Uint8 0 0 2147483647 ‎- High Level
52614 Uint8 0 0 1 0 – No Event Only
1 – Yes
52611 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7464 Uint8 0 0 10 Predefined Number Send SMS To
8464 String BLE 2 Custom 5 0 160 Predefined Number SMS Text
51210 Uint8 0 0 3 0 – None Priority BLE 3 Custom 1
1 – Low
2 – High
3 – Panic
51213 Uint8 0 0 2147483647 ‎- Low Level
51212 Uint8 0 0 2147483647 ‎- High Level
51214 Uint8 0 0 1 0 – No Event Only
1 – Yes
51211 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7455 Uint8 0 0 10 Predefined Number Send SMS To
8455 String BLE 3 Custom 1 0 160 Predefined Number SMS Text
52500 Uint8 0 0 3 0 – None Priority BLE 3 Custom 2
1 – Low
2 – High
3 – Panic
52503 Uint8 0 0 2147483647 ‎- Low Level
52502 Uint8 0 0 2147483647 ‎- High Level
52504 Uint8 0 0 1 0 – No Event Only
1 – Yes
52501 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7456 Uint8 0 0 10 Predefined Number Send SMS To
8456 String BLE 3 Custom 2 0 160 Predefined Number SMS Text
52540 Uint8 0 0 3 0 – None Priority BLE 3 Custom 3
1 – Low
2 – High
3 – Panic
52543 Uint8 0 0 2147483647 ‎- Low Level
52542 Uint8 0 0 2147483647 ‎- High Level
52544 Uint8 0 0 1 0 – No Event Only
1 – Yes
52541 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7457 Uint8 0 0 10 Predefined Number Send SMS To
8457 String BLE 3 Custom 3 0 160 Predefined Number SMS Text
52580 Uint8 0 0 3 0 – None Priority BLE 3 Custom 4
1 – Low
2 – High
3 – Panic
52583 Uint8 0 0 2147483647 ‎- Low Level
52582 Uint8 0 0 2147483647 ‎- High Level
52584 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
52581 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7458 Uint8 0 0 10 Predefined Number Send SMS To
8458 String BLE 3 Custom 4 0 160 Predefined Number SMS Text
52620 Uint8 0 0 3 0 – None Priority BLE 3 Custom 5
1 – Low
2 – High
3 – Panic
52623 Uint8 0 0 2147483647 ‎- Low Level
52622 Uint8 0 0 2147483647 ‎- High Level
52624 Uint8 0 0 1 0 – No Event Only
1 – Yes
52621 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7465 Uint8 0 0 10 Predefined Number Send SMS To
8465 String BLE 3 Custom 5 0 160 Predefined Number SMS Text
51220 Uint8 0 0 3 0 – None Priority BLE 4 Custom 1
1 – Low
2 – High
3 – Panic
51223 Uint8 0 0 2147483647 ‎- Low Level
51222 Uint8 0 0 2147483647 ‎- High Level
51224 Uint8 0 0 1 0 – No Event Only
1 – Yes
51221 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7459 Uint8 0 0 10 Predefined Number Send SMS To
8459 String BLE 4 Custom 1 0 160 Predefined Number SMS Text
52510 Uint8 0 0 3 0 – None Priority BLE 4 Custom 2
1 – Low
2 – High
3 – Panic
52513 Uint8 0 0 2147483647 ‎- Low Level
52512 Uint8 0 0 2147483647 ‎- High Level
52514 Uint8 0 0 1 0 – No Event Only
1 – Yes
52511 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7460 Uint8 0 0 10 Predefined Number Send SMS To
8460 String BLE 4 Custom 2 0 160 Predefined Number SMS Text
52550 Uint8 0 0 3 0 – None Priority BLE 4 Custom 3
1 – Low
2 – High
3 – Panic
52553 Uint8 0 0 2147483647 ‎- Low Level
52552 Uint8 0 0 2147483647 ‎- High Level
52554 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
52551 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7461 Uint8 0 0 10 Predefined Number Send SMS To
8461 String BLE 4 Custom 3 0 160 Predefined Number SMS Text
52590 Uint8 0 0 3 0 – None Priority BLE 4 Custom 4
1 – Low
2 – High
3 – Panic
52593 Uint8 0 0 2147483647 ‎- Low Level
52592 Uint8 0 0 2147483647 ‎- High Level
52594 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
52591 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7462 Uint8 0 0 10 Predefined Number Send SMS To
8462 String BLE 4 Custom 4 0 160 Predefined Number SMS Text
52630 Uint8 0 0 3 0 – None Priority BLE 4 Custom 5
1 – Low
2 – High
3 – Panic
52633 Uint8 0 0 2147483647 ‎- Low Level
52632 Uint8 0 0 2147483647 ‎- High Level
52634 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
52621 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7466 Uint8 0 0 10 Predefined Number Send SMS To
8466 String BLE 4 Custom 5 0 160 Predefined Number SMS Text
50530 Uint8 0 0 3 0 – None Priority BLE Temp #1
1 – Low
2 – High
3 – Panic
50533 Uint8 0 -400 0 ‎°C Low Level
50532 Uint8 0 -400 1250 ‎°C High Level
50534 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50531 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7223 Uint8 0 0 10 Predefined Number Send SMS To
8223 String BLE Temp #1 0 160 Predefined Number SMS Text
50540 Uint8 0 0 3 0 – None Priority BLE Temp #2
1 – Low
2 – High
3 – Panic
50543 Uint8 0 -400 0 ‎°C Low Level
50542 Uint8 0 -400 1250 ‎°C High Level
50544 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50541 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7224 Uint8 0 0 10 Predefined Number Send SMS To
8224 String BLE Temp #2 0 160 Predefined Number SMS Text
50550 Uint8 0 0 3 0 – None Priority BLE Temp #3
1 – Low
2 – High
3 – Panic
50553 Uint8 0 -400 0 ‎°C Low Level
50552 Uint8 0 -400 1250 ‎°C High Level
50554 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50551 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7225 Uint8 0 0 10 Predefined Number Send SMS To
8225 String BLE Temp #3 0 160 Predefined Number SMS Text
50560 Uint8 0 0 3 0 – None Priority BLE Temp #4
1 – Low
2 – High
3 – Panic
50563 Uint8 0 -400 0 ‎°C Low Level
50562 Uint8 0 -400 1250 ‎°C High Level
50564 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50561 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7226 Uint8 0 0 10 Predefined Number Send SMS To
8226 String BLE Temp #4 0 160 Predefined Number SMS Text
50570 Uint8 0 0 3 0 – None Priority BLE Battery #1
1 – Low
2 – High
3 – Panic
50573 Uint8 0 0 100 ‎% Low Level
50572 Uint8 0 0 100 ‎°% High Level
50574 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50571 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7227 Uint8 0 0 10 Predefined Number Send SMS To
8227 String BLE Battery #1 0 160 Predefined Number SMS Text
50580 Uint8 0 0 3 0 – None Priority BLE Battery #2
1 – Low
2 – High
3 – Panic
50583 Uint8 0 0 100 ‎% Low Level
50582 Uint8 0 0 100 ‎°% High Level
50584 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50581 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7228 Uint8 0 0 10 Predefined Number Send SMS To
8228 String BLE Battery #2 0 160 Predefined Number SMS Text
50590 Uint8 0 0 3 0 – None Priority BLE Battery #3
1 – Low
2 – High
3 – Panic
50593 Uint8 0 0 100 ‎% Low Level
50592 Uint8 0 0 100 ‎°% High Level
50594 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50591 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7229 Uint8 0 0 10 Predefined Number Send SMS To
8229 String BLE Battery #3 0 160 Predefined Number SMS Text
50600 Uint8 0 0 3 0 – None Priority BLE Battery #4
1 – Low
2 – High
3 – Panic
50603 Uint8 0 0 100 ‎% Low Level
50602 Uint8 0 0 100 ‎°% High Level
50604 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50601 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7230 Uint8 0 0 10 Predefined Number Send SMS To
8230 String BLE Battery #4 0 160 Predefined Number SMS Text
50610 Uint8 0 0 3 0 – None Priority BLE Humidity #1
1 – Low
2 – High
3 – Panic
50613 Uint8 0 0 1000 ‎%RH Low Level
50612 Uint8 0 0 1000 ‎%RH High Level
50614 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50611 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7231 Uint8 0 0 10 Predefined Number Send SMS To
8231 String BLE Humidity #1 0 160 Predefined Number SMS Text
50620 Uint8 0 0 3 0 – None Priority BLE Humidity #2
1 – Low
2 – High
3 – Panic
50623 Uint8 0 0 1000 ‎%RH Low Level
50622 Uint8 0 0 1000 ‎%RH High Level
50624 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50621 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7232 Uint8 0 0 10 Predefined Number Send SMS To
8232 String BLE Humidity #2 0 160 Predefined Number SMS Text
50630 Uint8 0 0 3 0 – None Priority BLE Humidity #3
1 – Low
2 – High
3 – Panic
50633 Uint8 0 0 1000 ‎%RH Low Level
50632 Uint8 0 0 1000 ‎%RH High Level
50634 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50631 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7233 Uint8 0 0 10 Predefined Number Send SMS To
8233 String BLE Humidity #3 0 160 Predefined Number SMS Text
50640 Uint8 0 0 3 0 – None Priority BLE Humidity #4
1 – Low
2 – High
3 – Panic
50643 Uint8 0 0 1000 ‎%RH Low Level
50642 Uint8 0 0 1000 ‎%RH High Level
50644 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50641 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7234 Uint8 0 0 10 Predefined Number Send SMS To
8234 String BLE Humidity #4 0 160 Predefined Number SMS Text
50720 Uint8 0 0 3 0 – None Priority BT Status
1 – Low
2 – High
3 – Panic
50723 Uint8 0 0 4 ‎- Low Level
50722 Uint8 0 0 4 ‎- High Level
50724 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
50721 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7250 Uint8 0 0 10 Predefined Number Send SMS To
8250 String BT Status 0 160 Predefined Number SMS Text
52660 Uint8 0 0 3 0 – None Priority BLE Lock Discovered
1 – Low
2 – High
3 – Panic
52663 Uint8 0 0 0 - Low Level
52662 Uint8 0 0 1 - High Level
52664 Uint8 1 0 1 0 – No Event Only
1 – Yes
52661 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7469 Uint8 0 0 10 Predefined Number Send SMS To
8469 String BLE lock Discovered 0 160 Predefined Number SMS Text
50700 Uint8 1 0 3 0 – None Priority Charger Connected
1 – Low
2 – High
3 – Panic
50703 Uint8 0 0 0 ‎- Low Level
50702 Uint8 0 0 1 ‎- High Level
50704 Uint8 1 0 1 0 – No Event Only
1 – Yes
50701 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7244 Uint8 0 0 10 Predefined Number Send SMS To
8244 String Charger Connected 0 160 Predefined Number SMS Text
51730 Uint8 0 0 3 0 – None Priority Coordinates ISO6709
1 – Low
2 – High
3 – Panic
51734 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
51731 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7376 Uint8 0 0 10 Predefined Number Send SMS To
8376 String ISO6709 Coordinates 0 160 Predefined Number SMS Text
51770 Uint8 0 0 3 0 – None Priority Extended External Voltage
1 – Low
2 – High
3 – Panic
51773 Uint8 0 0 200000 mV Low Level
51772 Uint8 0 0 200000 mV High Level
51774 Uint8 0 0 1 0 – No Event Only
1 – Yes
2 – Crash
51771 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7380 Uint8 0 0 10 Predefined Number Send SMS To
8380 String Extended External Voltage 0 160 Predefined Number SMS Text
52640 Uint8 0 0 3 0 – None Priority BLE Lock Status
1 – Low
2 – High
3 – Panic
52643 Uint8 0 0 0 - Low Level
52642 Uint8 0 0 1 - High Level
52644 Uint8 1 0 1 0 – No Event Only
1 – Yes
52641 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7467 Uint8 0 0 10 Predefined Number Send SMS To
8467 String BLE lock status 0 160 Predefined Number SMS Text
52650 Uint8 0 0 3 0 – None Priority BLE Lock Battery
1 – Low
2 – High
3 – Panic
52653 Uint8 0 0 100 % Low Level
52652 Uint8 0 0 100 % High Level
52654 Uint8 1 0 1 0 – No Event Only
1 – Yes
52651 Uint8 3 0 6 0 – On Exit Operand
1 – On Entrance
2 – On Both
3 – Monitoring
4 – On Hysteresis
5 – On Change
6 – On Delta Change
7468 Uint8 0 0 10 Predefined Number Send SMS To
8468 String BLE lock Battery 0 160 Predefined Number SMS Text