From Wiki Knowledge Base | Teltonika GPS
System parameters
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
138
|
Uint8
|
0
|
0
|
8
|
1 – Ignition
|
Movement source
|
2 – Accelerometer
|
4 – GNSS
|
8 - CAN Speed
|
133
|
Uint8
|
0
|
0
|
1
|
0 – GNSS
|
Speed Source
|
1 – OBD / CAN
|
106
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
Static navigation
|
1 – Enable
|
112
|
Uint8
|
1
|
0
|
3
|
1 – Movement
|
Static navigation source
|
2 – Ignition
|
3 – Movement and Ignition
|
107
|
Uint8
|
2
|
0
|
2
|
0 – After Position Fix
|
Send/Save records without TS
|
1 – Always
|
2 – After Time Sync
|
108
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
LED Indication
|
1 – Enable
|
109
|
Uint8
|
10
|
1
|
15
|
0 – Undefined
|
GNSS source
|
1 – Beidou only
|
2 – Glonass only
|
3 – Glonass and Beidou not allowed
|
4 – Galileo only
|
5 – Galileo and Beidou
|
6 – Galileo and Glonass
|
7 – Galileo, Glonass and Beidou not allowed
|
8 – Gps only
|
9 – Gps and Beidou
|
10 – Gps and Glonass
|
11 – Gps, Glonass and Beidou not allowed
|
12 – Gps and Galileo
|
13 – Gps, Galileo and Beidou
|
14 – Gps, Galileo and Glonass
|
15 – Gps, Galileo, Glonass and Beidou and not allowed
|
110
|
Uint8
|
0
|
0
|
1
|
0 – On need
|
Battery charge mode
|
1 – After ignition on
|
113
|
Uint8
|
0
|
0
|
1
|
0 – Codec 8
|
Data Protocol
|
1 – Codec 8 Extended
|
135
|
Uint8
|
0
|
0
|
1
|
0 – DIN2/AIN1
|
Input mode
|
1 – Ground Sense
|
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
102
|
Uint8
|
2
|
0
|
4
|
0 – Disable
|
Sleep settings
|
1 – GPS sleep
|
2 – Deep sleep
|
3 – Online Deep sleep
|
4 – Ultra Deep sleep
|
6 – Power Off sleep (only for FMB965)
|
103
|
Uint16
|
1
|
1
|
3000
|
Minutes
|
Timeout
|
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
101
|
Uint8
|
4
|
1
|
14
|
1 – DIN 1
|
Ignition settings
|
2 – Accelerometer
|
3 – Digital Input or Accelerometer
|
4 - Power Voltage
|
5 - Digital Input or Power Voltage
|
6 - Accelerometer or Power Voltage
|
7 – Digital Input, Accelerometer, or Power Voltage
|
8 - Engine RPM
|
9 - Digital Input or Engine RPM
|
10 - Accelerometer or Engine RPM
|
11 - Digital Input, Accelerometer or Engine RPM
|
12 - Power Voltage or Engine RPM
|
13 - Digital Input, Power Voltage or Engine RPM
|
14 - Accelerometer, Power Voltage or Engine RPM
|
104
|
Uint16
|
30000
|
0
|
30000
|
mV
|
High voltage
|
105
|
Uint16
|
13200
|
0
|
29999
|
mV
|
Low voltage
|
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
19001
|
Uint16
|
5
|
1
|
60
|
Seconds
|
Movement Start Delay
|
19002
|
Uint16
|
60
|
5
|
300
|
Seconds
|
Movement Stop Delay
|
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
900
|
Uint8
|
1
|
0
|
3
|
0 – Gps only
|
Synchronization settings
|
1 – NITZ and NTP
|
2 – NTP
|
3 – NITZ
|
901
|
Uint8
|
0
|
0
|
24
|
Hours
|
NTP Resync
|
902
|
Char
|
"avl1.teltonika.lt"
|
0
|
55
|
String
|
NTP server 1
|
903
|
Char
|
"pool.ntp.org"
|
0
|
55
|
String
|
NTP server 2
|
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
169
|
Uint8
|
2
|
0
|
2
|
0 – Disabled
|
Accelerometer Auto Calibration
|
1 – Once
|
2 – Continuous
|
170
|
Uint8
|
1
|
0
|
1
|
0 Disabled
|
Gravity Filter
|
1 Enabled
|
GPRS parameters
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1000
|
Uint32
|
300
|
30
|
259200
|
Seconds
|
Open link timeout
|
1001
|
Uint16
|
30
|
5
|
300
|
Seconds
|
Response timeout
|
1002
|
Uint8
|
0
|
0
|
1
|
0 – Newest
|
Sort by
|
1 – Oldest
|
1003
|
Uint16
|
0
|
0
|
300
|
Seconds
|
Network ping timeout
|
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
2000
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
GPRS context
|
1 – Enable
|
2001
|
Char
|
""
|
0
|
32
|
String
|
APN
|
2002
|
Char
|
""
|
0
|
32
|
String
|
APN username
|
2003
|
Char
|
""
|
0
|
32
|
String
|
APN password
|
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
2004
|
Char
|
""
|
0
|
55
|
String
|
Domain
|
2005
|
Uint16
|
0
|
0
|
65535
|
Number
|
Port
|
2006
|
Uint8
|
1
|
0
|
1
|
0 – TCP
|
Protocol
|
1 – UDP
|
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
2010
|
Uint8
|
0
|
0
|
3
|
0 - Disable
|
Backup Server Mode
|
1 - Backup
|
2 - Duplicate
|
3 - EGTS
|
2007
|
Char
|
""
|
0
|
55
|
String
|
Backup Server Domain
|
2008
|
Uint16
|
0
|
0
|
65535
|
Number
|
Backup Server Port
|
2009
|
Uint8
|
0
|
0
|
1
|
0 - TCP
|
Backup Server Protocol
|
1 - UDP
|
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
13003
|
Uint8
|
1
|
0
|
1
|
0 - Disable
|
FOTA WEB Status
|
1 – Enable
|
13000
|
Char
|
fm.teltonika.lt
|
0
|
55
|
String
|
FOTA WEB Domain
|
13001
|
Uint16
|
5000
|
0
|
65535
|
Number
|
FOTA WEB Port
|
13002
|
Uint16
|
720
|
30
|
65535
|
Number
|
FOTA WEB Period
|
SMS/Call settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
3000
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Allow SMS data sending
|
1 – Enable
|
3001
|
Char
|
""
|
0
|
16
|
String
|
Data Send Number
|
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
3003
|
Char
|
""
|
0
|
5
|
String
|
Login
|
3004
|
Char
|
""
|
0
|
5
|
String
|
Password
|
3006
|
Uint16
|
UTC+00:00
|
UTC-12:00
|
UTC+13:00
|
Time zone
|
SMS event Time Zone
|
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
3005
|
Uint8
|
0
|
0
|
4
|
0 – Do nothing
|
Incoming call action
|
1 – Hangup
|
2 – Report position
|
3 – Spy call
|
4 – Auto answer
|
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
3007
|
Uint8
|
0
|
0
|
7 (3 for FMB125)
|
0 – Disable
|
Outgoing call trigger
|
1 – DIN1
|
2 – Crash event
|
3 – DIN1 and Crash event
|
4 – DIN2
|
5 – DIN1 and DIN2
|
6 – DIN2 and Crash event
|
7 – DIN1, DIN2 and Crash event
|
3008
|
Uint8
|
0
|
0
|
10
|
GSM number
|
GSM number index
|
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
4000-4199
|
Char
|
""
|
0
|
16
|
String
|
Authorized number
|
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
6000-6009
|
Char
|
""
|
0
|
16
|
String
|
Predefined number
|
GSM operators
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
5000-5049
|
Uint32
|
0
|
0
|
999999
|
Number
|
SIM1 roaming operator list
|
9500-9549
|
Uint32
|
0
|
0
|
999999
|
Number
|
SIM2 roaming/home operator list
|
5500-5549
|
Uint32
|
0
|
0
|
999999
|
Number
|
Operator blacklist
|
Tracking settings
Records settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
107
|
Uint8
|
2
|
0
|
2
|
0 – After position fix
|
Saving sending mode
|
1 – Always
|
2 – After time sync
|
1002
|
Uint8
|
0
|
0
|
1
|
0 – Newest
|
Sort by
|
1 – Oldest
|
113
|
Uint8
|
1
|
1
|
1
|
1 – Codec 8 Extended
|
Data Protocol
|
Home Network GSM operator code "Vehicle on STOP" parameters
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10000
|
Uint16
|
3600
|
0
|
65535
|
Min Period
|
10004
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10005
|
Uint16
|
120
|
0
|
65535
|
Send Period
|
Home Network GSM operator code "Vehicle MOVING" parameters
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10050
|
Uint16
|
300
|
0
|
65535
|
Min Period
|
10051
|
Uint16
|
100
|
0
|
65535
|
Min Distance
|
10052
|
Uint8
|
10
|
0
|
180
|
Min Angle
|
10053
|
Uint8
|
10
|
0
|
100
|
Min Speed Delta
|
10054
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10055
|
Uint16
|
120
|
0
|
65535
|
Send Period
|
Roaming Network GSM operator code "Vehicle on STOP" parameters
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10100
|
Uint16
|
3600
|
0
|
65535
|
Min Period
|
10104
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10105
|
Uint16
|
0
|
0
|
65535
|
Send Period
|
Roaming Network GSM operator code "Vehicle MOVING" parameters
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10150
|
Uint16
|
300
|
0
|
65535
|
Min Period
|
10151
|
Uint16
|
100
|
0
|
65535
|
Min Distance
|
10152
|
Uint8
|
10
|
0
|
180
|
Min Angle
|
10153
|
Uint8
|
10
|
0
|
100
|
Min Speed Delta
|
10154
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10155
|
Uint16
|
0
|
0
|
65535
|
Send Period
|
Unknown Network GSM operator code "Vehicle on STOP" parameters
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10200
|
Uint16
|
3600
|
0
|
65535
|
Min Period
|
10204
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10205
|
Uint16
|
120
|
0
|
65535
|
Send Period
|
Unknown Network GSM operator code "Vehicle MOVING" parameters
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10250
|
Uint16
|
300
|
0
|
65535
|
Min Period
|
10251
|
Uint16
|
100
|
0
|
65535
|
Min Distance
|
10252
|
Uint8
|
10
|
0
|
180
|
Min Angle
|
10253
|
Uint8
|
10
|
0
|
100
|
Min Speed Delta
|
10254
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10255
|
Uint16
|
0
|
0
|
65535
|
Send Period
|
Features
Driving behavior
Overspeeding
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1025500
|
Uint8
|
0
|
0
|
2
|
0 – Disable
|
Priority
|
1 – Low priority
|
2 – High priority
|
11104
|
Uint16
|
90
|
0
|
260
|
km/h
|
Max speed
|
Trip
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1025000
|
Uint8
|
0
|
0
|
2
|
0 – Disable
|
Priority
|
1 – Low priority
|
2 – High priority
|
11803
|
Uint8
|
5
|
0
|
255
|
km/h
|
Start speed
|
11804
|
Uint16
|
60
|
0
|
65535
|
Seconds
|
Ignition OFF timeout
|
Odometer
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1001600
|
Uint8
|
0
|
0
|
2
|
0 – Disable
|
Priority
|
1 – Low priority
|
2 – High priority
|
11807
|
Uint32
|
0
|
0
|
4294967
|
Kilometer
|
Odometer value
|
Vehicle protection
Unplug Detection
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1025200
|
Uint8
|
0
|
0
|
2
|
0 – Disable
|
Priority
|
1 – Low priority
|
2 – High priority
|
Other features
Static navigation
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
106
|
Uint8
|
0
|
0
|
2
|
0 – Disable
|
Priority
|
1 – Low priority
|
2 – High priority
|
Digital output overcurrent recovery
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
350
|
Uint8
|
0
|
0
|
2
|
0 – Disable
|
Priority
|
1 – Low priority
|
2 – High priority
|
|}