Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
101
|
Uint8
|
4
|
1
|
7
|
1 – Digital Input
|
Ignition settings
|
2 – Power Voltage
|
3 – Digital Input or Power Voltage
|
4 - Accelerometer
|
5 - Digital Input or Accelerometer
|
6 - Accelerometer or Power Voltage
|
7 – Digital Input, Accelerometer, or Power Voltage
}
Movement settings
Tracking settings
Records settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
107
|
Uint8
|
2
|
0
|
2
|
0 – After position fix
|
Saving sending mode
|
1 – Always
|
2 – After time sync
|
1002
|
Uint8
|
0
|
0
|
1
|
0 – Newest
|
Sort by
|
1 – Oldest
|
113
|
Uint8
|
1
|
1
|
1
|
1 – Codec 8 Extended
|
Data Protocol
|
Records profile settings
On Stop
Home
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10000
|
Uint16
|
3600
|
0
|
2592000
|
Min Period
|
10004
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10005
|
Uint16
|
120
|
0
|
2592000
|
Send Period
|
Roaming
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10100
|
Uint16
|
3600
|
0
|
2592000
|
Min Period
|
10104
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10105
|
Uint16
|
0
|
0
|
2592000
|
Send Period
|
Moving
Home
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10050
|
Uint16
|
300
|
0
|
2592000
|
Min Period
|
10051
|
Uint16
|
100
|
0
|
65535
|
Min Distance
|
10052
|
Uint8
|
10
|
0
|
180
|
Min Angle
|
10053
|
Uint8
|
10
|
0
|
100
|
Min Speed Delta
|
10054
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10055
|
Uint16
|
120
|
0
|
2592000
|
Send Period
|
Roaming
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10150
|
Uint16
|
300
|
0
|
2592000
|
Min Period
|
10151
|
Uint16
|
100
|
0
|
65535
|
Min Distance
|
10152
|
Uint8
|
10
|
0
|
180
|
Min Angle
|
10153
|
Uint8
|
10
|
0
|
100
|
Min Speed Delta
|
10154
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10155
|
Uint16
|
0
|
0
|
2592000
|
Send Period
|
Features
Driving behavior
Overspeeding
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1025500
|
Uint8
|
0
|
0
|
2
|
0 – Disable
|
Priority
|
1 – Low priority
|
2 – High priority
|
11104
|
Uint16
|
90
|
0
|
260
|
km/h
|
Max speed
|
Trip
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1025000
|
Uint8
|
0
|
0
|
2
|
0 – Disable
|
Priority
|
1 – Low priority
|
2 – High priority
|
11803
|
Uint8
|
5
|
0
|
255
|
km/h
|
Start speed
|
11804
|
Uint16
|
60
|
0
|
65535
|
Seconds
|
Ignition OFF timeout
|
Odometer
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1001600
|
Uint8
|
0
|
0
|
2
|
0 – Disable
|
Priority
|
1 – Low priority
|
2 – High priority
|
11807
|
Uint32
|
0
|
0
|
4294967
|
Kilometer
|
Odometer value
|
Vehicle protection
Unplug Detection
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1025200
|
Uint8
|
0
|
0
|
2
|
0 – Disable
|
Priority
|
1 – Low priority
|
2 – High priority
|
Other features
Static navigation
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
106
|
Uint8
|
0
|
0
|
2
|
0 – Disable
|
Priority
|
1 – Low priority
|
2 – High priority
|
Digital output overcurrent recovery
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
350
|
Uint8
|
0
|
0
|
2
|
0 – Disable
|
Priority
|
1 – Low priority
|
2 – High priority
|
SMS / Call settings
SMS Security
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
3004
|
Char
|
""
|
0
|
5
|
String
|
Password
|
|