From Wiki Knowledge Base | Teltonika GPS
Mobile network
Mobile data settings
SIM 1 Settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
2001
|
Char
|
""
|
0
|
32
|
String
|
APN
|
2002
|
Char
|
""
|
0
|
32
|
String
|
APN username
|
2003
|
Char
|
""
|
0
|
32
|
String
|
APN password
|
2016
|
Uint8
|
1
|
0
|
1
|
0 – PAP
|
GPRS authentication
|
1 – CHAP
|
Server Settings
Primary server settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
2004
|
Char
|
""
|
0
|
55
|
String
|
Domain
|
2005
|
Uint16
|
0
|
0
|
65535
|
Number
|
Port
|
2006
|
Uint8
|
0
|
0
|
3
|
0 – TCP
|
Protocol
|
1 – UDP
|
Server communication settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1000
|
Uint32
|
300
|
30
|
259200
|
Seconds
|
Open link timeout
|
1001
|
Uint16
|
30
|
5
|
300
|
Seconds
|
Response timeout
|
1003
|
Uint16
|
0
|
0
|
300
|
Seconds
|
Keep-alive
|
FOTA WEB settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
13003
|
Uint8
|
1
|
0
|
1
|
0 - Disable
|
FOTA WEB Settings
|
1 – Enable
|
13000
|
Char
|
fm.teltonika.lt
|
0
|
55
|
String
|
Domain
|
13001
|
Uint16
|
5005
|
0
|
65535
|
Number
|
Port
|
13001
|
Uint16
|
5055
|
0
|
65535
|
Number
|
Pinger port
|
System parameters
Ignition settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
101
|
Uint8
|
4
|
2
|
7
|
1 – Digital Input
|
Ignition settings
|
2 – Power Voltage
|
3 – Digital Input or Power Voltage
|
4 - Accelerometer
|
5 - Digital Input or Accelerometer
|
6 - Accelerometer or Power Voltage
|
7 – Digital Input, Accelerometer or Power Voltage
|
Movement settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
138
|
Uint8
|
2
|
1
|
15
|
1 – Accelerometer
|
Movement source
|
2 – GNSS
|
3 – Accelerometer or GNSS
|
4 - Power Voltage
|
5 - Accelerometer or Power Voltage
|
6 - GNSS or Power Voltage
|
7 – Accelerometer, GNSS or Power Voltage
|
8 – Digital Input
|
9 – Accelerometer or Digital Input
|
10 – Digital Input or GNSS
|
12 – Digital Input or Power Voltage
|
15 – Accelerometer, GNSS, Power Voltage or Digital Input
|
Tracking settings
Records settings
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
107
|
Uint8
|
2
|
0
|
2
|
0 – After position fix
|
Saving sending mode
|
1 – Always
|
2 – After time sync
|
1002
|
Uint8
|
0
|
0
|
1
|
0 – Newest
|
Sort by
|
1 – Oldest
|
113
|
Uint8
|
1
|
1
|
1
|
1 – Codec 8 Extended
|
Data Protocol
|
Records profile settings
On Stop
Home
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10000
|
Uint16
|
3600
|
0
|
2592000
|
Min Period
|
10004
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10005
|
Uint16
|
120
|
0
|
2592000
|
Send Period
|
Roaming
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10100
|
Uint16
|
3600
|
0
|
2592000
|
Min Period
|
10104
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10105
|
Uint16
|
0
|
0
|
2592000
|
Send Period
|
Moving
Home
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10050
|
Uint16
|
300
|
0
|
2592000
|
Min Period
|
10051
|
Uint16
|
100
|
0
|
65535
|
Min Distance
|
10052
|
Uint8
|
10
|
0
|
180
|
Min Angle
|
10053
|
Uint8
|
10
|
0
|
100
|
Min Speed Delta
|
10054
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10055
|
Uint16
|
120
|
0
|
2592000
|
Send Period
|
Roaming
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Parameter name
|
Min
|
Max
|
10150
|
Uint16
|
300
|
0
|
2592000
|
Min Period
|
10151
|
Uint16
|
100
|
0
|
65535
|
Min Distance
|
10152
|
Uint8
|
10
|
0
|
180
|
Min Angle
|
10153
|
Uint8
|
10
|
0
|
100
|
Min Speed Delta
|
10154
|
Uint8
|
1
|
1
|
255
|
Min Saved Records
|
10155
|
Uint16
|
0
|
0
|
2592000
|
Send Period
|
Features
Driving behavior
Overspeeding
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1025500
|
Uint8
|
0
|
0
|
2
|
0 – Disable
|
Priority
|
1 – Low priority
|
2 – High priority
|
11104
|
Uint16
|
90
|
0
|
260
|
km/h
|
Max speed
|
Trip
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1025000
|
Uint8
|
0
|
0
|
2
|
0 – Disable
|
Priority
|
1 – Low priority
|
2 – High priority
|
11803
|
Uint8
|
5
|
0
|
255
|
km/h
|
Start speed
|
11804
|
Uint16
|
60
|
0
|
65535
|
Seconds
|
Ignition OFF timeout
|
Odometer
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1001600
|
Uint8
|
0
|
0
|
2
|
0 – Disable
|
Priority
|
1 – Low priority
|
2 – High priority
|
11807
|
Uint32
|
0
|
0
|
4294967
|
Kilometer
|
Odometer value
|
Vehicle protection
Unplug Detection
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1025200
|
Uint8
|
0
|
0
|
2
|
0 – Disable
|
Priority
|
1 – Low priority
|
2 – High priority
|
Other features
Static navigation
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
106
|
Uint8
|
0
|
0
|
2
|
0 – Disable
|
Priority
|
1 – Low priority
|
2 – High priority
|
Digital output overcurrent recovery
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
350
|
Uint8
|
0
|
0
|
2
|
0 – Disable
|
Priority
|
1 – Low priority
|
2 – High priority
|
SMS / Call settings
SMS Security
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
3004
|
Char
|
""
|
0
|
5
|
String
|
Password
|