FMB+FMB Backup Tracker

From Teltonika Telematics Wiki
Revision as of 14:07, 6 December 2023 by Arnas.Zeb (talk | contribs) (Text replacement - "Bluetooth" to "Bluetooth®")

Introduction to Backup Tracker functionality

FMB+FMB Backup Tracker is a new feature which allows to transform device's work-mode to work as a backup tracker.
Each backup tracker's scan cycle lasts up to 60 seconds. If during those 60 seconds the Backup tracker is:

  • Able to catch 15 valid Main tracker packets, the scan will stop and the device will wait for next cycle to start.
  • Unable to catch at least 15 valid Main tracker packets, an alarm record will be generated with AVL ID 1153. After delay timeout (s) is reached, device will send that generated record to the server and enable other record generation/sending (Periodic and Eventual record).

Backup functionality logic

Each time the device is starts up or gets reconfigured, it checks if either main or backup tracker modes are enabled on the current configuration.
Both modes have some common initialization procedures:

  • Check if Sleep Mode (ID: 102) is configured to Ultra Sleep (4). If it is, set Sleep Mode to Disabled (0). This means that both tracker modes overwrite configured Ultra Sleep mode and it‘s impossible to use Ultra Sleep mode with this functionality enabled;
  • Non stop scanning (ID: 1115) is set Disable (0);
  • BLE connection control (ID: 1112) is set to Prohibit (0);
  • All BLE connectionless functionalities are set to Disabled (0).

Then, both modes have some unique initialization procedures (specific to the tracker mode): Main tracker mode:

  • Beacon Detection (ID: 134) is set to Disabled (0);
  • BLE packet sending gets initialized and works according to flowchart.

Backup tracker mode:

  • Beacon Detection (ID: 134) is set to All (1);
  • All record generation is disabled. This means that if the device is not detecting the main tracker and starts generating records, it can be reconfigured or hard reset, and it will only start generating records again after the next failed scan (aka after next alarm record).
  • Record sending is queued up to stop. Device waits for any currently queued up record sending to finish, so there might be a delay for this full record sending stop to occur.




Packet format

Parameter list

Parameter ID Name Data Type Value range Description
Min Max Default
70200 FMB Tracker mode Uint8 0 2 0 0 - Disabled;
1 - Main;
2 - Backup.
70201 FMB Tracker mode String - 15 - IMEI of the tracker which is configured as a main tracker
70202 Update frequency Uint16 60 65535 120 Frequency, at which backup tracker should start scanning for Main Tracker BLE packets.
70203 Delay timeout Uint16 0 65535 0 Delay, after which backup tracker starts sending records after an alarm occurs

Firmware compatibility

To start working with FMB + FMB functionality 03.27.13.Rev.452 firmware or newer will be required to be used. You can check what devices are compatible with using this firmware on Compability table for FMB + FMB backup tracking page.

Limitations

Since the feature relies on Bluetooth® functionality, all of the existing Bluetooth® limitations are applied. One of such limitations is the fact that FMB devices only store up to 100 BLE devices per scan. This means, that if there are more than 100 BLE devices in the surrounding environment, backup tracker being able to catch main tracker packets in time gets reduced.

Setup instructions

To ENABLE backup feature on FMBxxx device:

Both devices:

  • Make sure Ultra Sleep mode → Disabled

  • Bluetooth®BT Radio set to Enable(visible)



Main device:

  • Bluetooth® 4.0 → select Main Tracker



Backup device:

  • Bluetooth® 4.0 → select Backup Tracker
  • Enter main device IMEI (15 digits)
  • Set Update frequency to how frequent you want backup tracker to scan.
  • Set Delay timeout to delay sending alarm record. Leave it default (0) if you want to immediately receive alarm record.

  • Configure your APN and Server settings in GPRS section.

Parsed data


000000000000004A8E010000016B412CEE0001000000000000000000000000000000 0481 0005000100010100010011001D00010010015E2C880002000B00000000
3544C87A000E000000001DD7E06A00000100002994

AVL Data Packet
AVL Data Packet Part HEX Code Part
Zero Bytes 00 00 00 00
Data Field Length 00 00 00 4A
Codec ID 8E
Number of Data 1 (Records) 01
AVL Data Timestamp 00 00 01 6B 41 2C EE 00 (GMT: Monday, June 10, 2019 11:36:32 AM)
Priority 01
Longitude 00 00 00 00
Latitude 00 00 00 00
Altitude 00 00
Angle 00 00
Satellites 00
Speed 00 00
Event IO ID 04 81 (AVL: 1153 - Backup Tracker Alarm)
N of Total ID 00 05
N1 of One Byte IO 00 01
1’st IO ID 00 01 (AVL ID: 1, Name: DIN1)
1’st IO Value 01
N2 of Two Bytes IO 00 01
1’st IO ID 00 11 (AVL ID: 17, Name: Axis X)
1’st IO Value 00 1D
N4 of Four Bytes IO 00 01
1’st IO ID 00 10 (AVL ID: 16, Name: Total Odometer)
1’st IO Value 01 5E 2C 88
N8 of Eight Bytes IO 00 02
1’st IO ID 00 0B (AVL ID: 11, Name: ICCID1)
1’st IO Value 00 00 00 00 35 44 C8 7A
2’nd IO ID 00 0E (AVL ID: 14, Name: ICCID2)
2’nd IO Value 00 00 00 00 1D D7 E0 6A
NX of X Byte IO 00 00
Number of Data 2 (Number of Total Records) 01
CRC-16 00 00 29 94