Template:ATX System
Power Saving settings

Puts the device into a power-saving mode, preserving the power consumption from the external source or the internal battery. The device enters this mode after the conditions are met.
Online sleep
- In Online Sleep mode, the device manages the connection only when records need to be sent. The connection is opened at periodic intervals to send records and closed immediately after, without any timeout.
- Changing the Permanent Link setting during Online Sleep will wake up the device to apply the new configuration.
- With Permanent Link enabled, the device maintains a constant connection, sending records immediately as they are generated, rather than waiting for the next scheduled send. After sending connection remains open.
Disabled modules in Online sleep
When device goes into sleep mode, some modules are turned off to consume less power. Listed below are the modules and scenarios that are turned off in common with all modes and those that are disabled specifically for the Online sleep mode:
- GNSS
- Scenarios (Common):
- Odometer
- Data acquisition
- SNTP time synchronization
- Overspeeding
- Trip
- Unplug Detection
- Jamming Detection
- Eco Driving
Online sleep entry conditions
All entry conditions must be met:
- Ignition (configured ignition source) is off.
- Movement is not detected by the configured movement source.
- Device time must be synchronized. This condition depends on the “Record Settings -> Saving / sending mode parameter.
- After Position Fix - device time is synchronized with GNSS satellites and GPS fix is obtained.
- After Time Sync - device time is synchronized over NTP, NITZ, or GNSS satellites.
- Always - device will enter sleep mode without time synchronization and GPS fix.
- Sleep timeout is reached.
- There are no SMS messages being received.
- Data sockets are closed (ignored when permanent link is enabled)
- FOTA WEB connection is not in progress.
Online sleep exit conditions
At least one exit condition must be met:
- Ignition is ON.
- Movement is detected.
- Periodic wake-up (if enabled).
Power off sleep
Disabled modules in Power off sleep
When device goes into sleep mode, some modules are turned off to consume less power. Listed below are the modules and scenarios that are turned off in common with all modes and those that are disabled specifically for the Power off sleep mode:
- Modem
- Record sending
- GNSS
- IMU (Inertial Measurement Unit)
- FOTA WEB
- Charger service
- Scenarios (Common):
- LEDs (Navigation and Status)
- Odometer
- Data acquisition
- SNTP time synchronization
- Overspeeding
- Trip
- Unplug Detection
- Jamming Detection
- Eco Driving
Power off entry conditions
All entry conditions must be met:
- Ignition (configured ignition source) is off.
- Movement is not detected by the configured movement source.
- Device time must be synchronized. This condition depends on the “Record Settings -> Saving / sending mode parameter.
- After Position Fix - device time is synchronized with GNSS satellites and GPS fix is obtained.
- After Time Sync - device time is synchronized over NTP, NITZ, or GNSS satellites.
- Always - device will enter sleep mode without time synchronization and GPS fix.
- Sleep timeout is reached.
- There are no SMS messages being received.
- Data sockets are closed (ignored when permanent link is enabled)
- FOTA WEB connection is not in progress.
Power off sleep exit conditions
At least one exit condition must be met:
- Ignition is ON.
- Movement is detected.