Jump to content

TEST-DM

From Teltonika Telematics Wiki

Parameter list (short)

PARAMETER ID NAME UNITS DESCRIPTION VALUE
900007 Speed limit km/h Speed threshold which determines when to generate speeding start/stop events. Min=0
Max=1000
Default="0"
1024900 Network jamming detection - The feature detects GSM jamming, initiates actions using an output, and helps to prevent vehicle theft when jamming devices are used. A low signal level is not equal to GSM jamming, the device recognizes these events. 0 = Disable
1 = Low priority
2 = High priority
empty empty empty empty empty

Parameter list (full)

PARAMETER ID NAME UNITS/VALUES DESCRIPTION TYPE MIN MAX DEFAULT
900007 Speed limit km/h Speed threshold which determines when to generate speeding start/stop events. Uint16 0 1000 0
1024900 Network jamming detection 0 = Disable, 1 = Low priority, 2 = High priority The feature detects GSM jamming, initiates actions using an output, and helps to prevent vehicle theft when jamming devices are used. A low signal level is not equal to GSM jamming, the device recognizes these events. Uint8 0 2 0
DOUT1= 899901
DOUT2=899911
DOUT3=899921
Activation timing 1=Outside
2=Inside
Select Activation timing when the event will be triggered.
Control mode - Persistent:
  • Outside activation timing, selected DOUT will start being controlled while the device is outside of the geozone and will stop being controlled while the device is inside of the geozone. If the device is outside of multiple geozones, selected DOUT will continue being controlled until the device enters one of the geozones.
  • Inside activation timing, selected DOUT will start being controlled while the device is inside the geozone and will stop being controlled while the device is outside of the geozone. If Output control according to speed limit is set, selected DOUT will start being controlled while the device is exceeding the speed limit inside the geozone. If the device is inside multiple geozones, selected DOUT will continue being controlled until the device is outside of all geozones (or stops exceeding the speed limit, if configured).

Control mode - Event:

  • Outside activation timing, selected DOUT will be triggered once you exit the configured geozone.
  • Inside activation timing, selected DOUT will be triggered once you enter the configured geozone.
Uint8 1 2 1