Template:FM36YX Scenarios settings

From Wiki Knowledge Base | Teltonika GPS

In Scenarios window six different scenarios are available: Green driving, Over Speeding, Excessive Idling, Immobilizer, iButton List checking and Jamming. All scenarios can use DOUT together, but if DOUT1 is assigned to Immobilizer, other scenarios can’t control it.

FM36YX Scenarios configuration.png

Digital Output (open drain grade) usage in scenarios:



Green Driving


Helps to prevent and inspect driver about harsh driving. Scenario continuously monitors: accelerating force, braking force and cornering angles. Warns driver if needed. DOUT1 or DOUT2 is controlled by scenario for user needs, for example buzzer or LED.
To save 3G/GPRS traffic Green Driving event will be generated (included into sent records) only when measured values are higher than those set in configuration, without additional I/O settings.
To prevent generating false events, harsh acceleration and harsh braking is monitored only when following conditions are fulfilled:

  • Ignition is ON (DIN1 = 1)
  • Vehicle speed is equal or higher than 10km/h

Harsh cornering is monitored only when following conditions are fulfilled:

  • Ignition is ON (DIN1 = 1)
  • Vehicle speed is equal or higher than 30km/h

Bw nb.png Note: Green Driving Scenario is a factor on various cars and various drivers testing phase and can be subject to changes. Teltonika is constantly working on improvement of the functionality of the devices, and strongly recommends using the latest version of the firmware.

Digital output control:
DOUTX is ON (DOUTX is selected digital input) for:

  • 3sec. if detected value is over (0; 30] % from preconfigured allowed value;
  • 5sec. if detected value is over (30; 50] % from preconfigured allowed value;
  • 7sec. if detected value is over (50; -] % from preconfigured allowed value.

After period of time DOUTX is turned OFF.

Over Speeding


Helps to prevent from exceeding fixed speed and inspects driver if needed. DOUT1 or DOUT2 is controlled by scenario for user needs, to manage buzzer, LED, etc.

Digital output control:
DOUTX (selected digital output) is ON, while vehicle speed exceeds parameter value. DOUTX is activated until current speed decreases below parameter value.

Excessive Idling Detection


If ignition is ON and no movement, event will be generated when TMO reached. User can enable this functionality, select timeouts for stationary time and for movement time.

Jamming detection


DOUT1 is ON (if selected DOUT1), while modem is fixing radio frequency jamming. After jamming is over, DOUT1 is deactivated.

Authorized driving


DOUT2 is continuously OFF. Dout2 (if selected DOUT2) turns ON if Ignition turns ON (configured Ignition Source=1). After authorizing iButton (iButton ID is read and it matches the ID from the iButton list), DOUT2 turns OFF. After successful authorization ignition can be turned OFF (configured Ignition Source =0) for no longer than 30 seconds, otherwise authorization must be repeated.

Immobilizer


(if selected DOUT2) DOUT2 is continuously OFF. Dout2 turns ON if Ignition turns ON (configured Ignition Source = 1). After iButton ID is read (any iButton is attached), DOUT2 turns OFF. After iButton identification, ignition can be turned OFF (configured Ignition Source = 0) for no longer than 30 seconds, otherwise immobilizer must be repeated.