Template:FMB630 Device Family Parameter list
From Wiki Knowledge Base | Teltonika GPS
Revision as of 07:19, 26 June 2018 by Linas.zaldokas (talk | contribs)
!Not finished
System parameters
Parameter | ID | Parameter value | Value type | ||||
---|---|---|---|---|---|---|---|
MIN | MAX | Default | Recommended | ||||
Sleep Mode | x000 | 0 | 3 | 0 | - | U8 | |
0 | Disable | ||||||
1 | Enable | ||||||
2 | Deep sleep | ||||||
3 | Online deep sleep | ||||||
Sleep Timeout | x001 | 0 | 9000 | 1 | - | U16 | |
Ignition source | x900 | 0 | 5 | 0 | - | U8 | |
0 | Power voltage | ||||||
1 | DIN 1 | ||||||
2 | DIN 2 | ||||||
3 | DIN 3 | ||||||
4 | DIN 4 | ||||||
5 | Movement | ||||||
High Voltage Level(for Ignition) | x901 | 0 | 30000 | 0 | - | U16 | |
Low Voltage Level (for Ignition) | x902 | 0 | 30000 | 0 | - | U16 |
GPRS data sending settings
Parameter | ID | Parameter value | Value type | |||
---|---|---|---|---|---|---|
MIN | MAX | Default | Recommended | |||
Server 1 | ||||||
GPRS Context Activation | x240 | 0 (Disable) | 1 (Enable) | 0 | - | S8 |
Protocol | 0 (TCP) | 1 (UDP) | 0 | - | U8 | |
Server Response Timeout | 5 | 300 | 5 | - | U16 | |
Domain | Empty | 56 char | Empty | - | - | |
Target Server Port | 0 | 65535 | 0 | - | U16 | |
Configuring format: | <Enable>,<IP>,<port>,<protocol>,<Server Reponse Tmo> | |||||
Server 2 | ||||||
GPRS Context Activation | x242 | 0 (Disable) | 1 (Enable) | 0 | - | S8 |
Protocol | 0 (TCP) | 1 (UDP) | 0 | - | U8 | |
Domain | Empty | 56 char | Empty | - | - | |
Target Server Port | 0 | 65535 | 0 | - | U16 | |
Configuring format: | <Enable>,<IP>,<port>,<protocol> |
GPRS data limit settings
Parameter | ID | Parameter value | Value type | |||
---|---|---|---|---|---|---|
MIN | MAX | Default | Recommended | |||
Enable GPRS limits | x241 | 0 (Disable) | 1 (Enable) | 0 | - | U8 |
Data limit Home | 1 | 10000 | 100 | - | U16 | |
Data limit Roaming | 1 | 10000 | 10 | - | U16 | |
Configuring format: | <Enable>,, |
SMS security settings
Parameter | ID | Parameter value | Value type | |||
---|---|---|---|---|---|---|
MIN | MAX | Default | Recommended | |||
SMS Login | x252 | Empty | 5 char | Empty | - | S8[5] |
SMS Password | x253 | Empty | 5 char | Empty | - | S8[5] |
Authorized phone numbers | x260-x269 | Empty | 16 char | Empty | - | S8[17] |
SMS data sending settings
Parameter | ID | Parameter value | Value type | |||
---|---|---|---|---|---|---|
MIN | MAX | Default | Recommended | |||
SMS Data | x250 | 0 (Disable) | 1 (Enable) | 0 | - | U8 |
SMS Data send week time schedule | x273 | Binary decoding | Binary decoding | - | - | 20 byte array |
Configuring format: | <x1><x2><x3><x4>......<x19> |
Operator list settings
Parameter | ID | Parameter value | Value type | |||
---|---|---|---|---|---|---|
MIN | MAX | Default | Recommended | |||
Preferred Operator | x271 | 0 | 99999999 | 0 | - | U32 |
Black List Operator | x272 | 0 | 99999999 | 0 | - | U32 |
Configuring format: (setparam Y271 X) |
X is start position. If no X is set starts from 0 Max 19 operator codes can be set (separated by comma) in one SMS command. | |||||
Reading format: (getparam Y271 X) |
X values can be 1,2,3. If X = 1, Operator codes from 0-19 are read from configuration and sent via SMS. If X = 2, Operator codes from 20-39 are read from configuration and sent via SMS. If X = 3, Operator codes from 40-49 are read from configuration and sent via SMS. If X = any other, Operator codes from 0-19 are read from configuration and sent via SMS *User must use X, without X value device responds that parameter is wrong or it can respond with wrong operator codes. |