From Teltonika Telematics Wiki
Green driving parameters
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1890
|
Uint8
|
-
|
0
|
1
|
0 – Disable
|
Scenario settings
|
1 – Enable
|
1891
|
Uint8
|
-
|
0
|
2
|
0 - disable
|
Digital Output Control
|
1 - DOUT1
|
2 - DOUT2
|
1909
|
Uint8
|
-
|
0
|
1
|
0 - GPS
|
Source
|
1 - Accelerometer
|
1892
|
Float
|
0.25
|
0.25
|
0.85
|
mG
|
Max Acceleration Force
|
1893
|
Float
|
0.35
|
0.25
|
0.85
|
mG
|
Max Braking Force
|
1894
|
Float
|
0.2
|
0.1
|
1.0
|
mG
|
Max Cornering Force
|
Overspeeding scenario parameters
Parameter ID
|
Parameter Type
|
Recommended value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1895
|
Uint8
|
0
|
0
|
1
|
0 – Disable
|
Scenario settings
|
1 – Enable
|
1896
|
Uint8
|
-
|
0
|
2
|
0 – None
|
Digital Output control
|
1 – DOUT 1
|
2 – DOUT 2
|
1897
|
Uint16
|
-
|
0
|
260
|
km/h
|
Max speed
|
Jamming scenario parameters
Parameter ID
|
Parameter Type
|
Recommended Value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1898
|
Uint8
|
-
|
0
|
1
|
0 – Disable
|
Scenario settings
|
1 – Enable
|
1899
|
Uint8
|
-
|
0
|
2
|
0 – None
|
Digital Output control
|
1 – DOUT1
|
2 – DOUT2
|
1900
|
Uint8
|
-
|
0
|
2
|
0 – Low sensitivity (50 RSSI)
|
Jamming sensitivity
|
1 – Medium sensitivity (30 RSSI)
|
2 – High sensitivity (10 RSSI)
|
1901
|
Uint16
|
60
|
0
|
65535
|
Seconds
|
Jamming Timeout
|
1902
|
Uint16
|
0
|
0
|
65535
|
Seconds
|
Jamming Pulse Duration
|
Immobilizer scenario parameters
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
1903
|
Uint8
|
-
|
0
|
1
|
0 – Disable
|
Scenario settings
|
1 – Enable
|
1904
|
Uint8
|
-
|
0
|
2
|
0 – Disable
|
Digital Output Control
|
1 – DOUT1
|
2 – DOUT2
|
Trip scenario parameters
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11800
|
Uint8
|
0
|
0
|
3
|
0 – Disable
|
Scenario settings
|
1 – Low priority
|
2 – High priority
|
3 – Panic priority
|
11801
|
Uint8
|
1
|
0
|
1
|
0 – Disable
|
Eventual records
|
1 – Enable
|
11802
|
Uint8
|
0
|
0
|
1
|
0 – Continuous
|
Mode
|
1 – Between records
|
11803
|
Uint8
|
5
|
0
|
255
|
km/h
|
Start speed
|
11804
|
Uint16
|
60
|
0
|
65535
|
Seconds
|
Ignition off timeout
|
7031
|
Uint8
|
0
|
0
|
10
|
Phone number
|
Send SMS to
|
8031
|
String
|
"Trip"
|
0
|
160
|
Text
|
Sms text
|
DOUT control via call scenario parameters
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
12000
|
Uint8
|
0
|
0
|
2 (1 for FMB125)
|
0 – None
|
Digital Output control
|
1 – DOUT 1
|
2 – DOUT 2
|
12001
|
Uint8
|
0
|
0
|
3 (1 for FMB125)
|
0 – None
|
DOUT deactivation
|
1 – DIN 1
|
2 – DIN 2
|
3 – DIN 3
|
12002
|
Int32
|
5
|
0
|
2147483647
|
Seconds
|
Duration timeout
|
iButton read notification
Parameter ID
|
Parameter Type
|
Default value
|
Value range
|
Value
|
Parameter name
|
Min
|
Max
|
11704
|
Uint8_t
|
0
|
0
|
1
|
0 - Disabled
|
DOUT control
|
1 - Enabled
|
11705
|
Uint16_t
|
200
|
100
|
50000
|
Milliseconds
|
DOUT duration
|
11706
|
Uint8_t
|
0
|
0
|
1
|
0 - Disabled
|
iButton notification list
|
1 - Enabled
|
11707
|
Uint8_t
|
0
|
0
|
1
|
0 - Disabled
|
Depend on ignition
|
1 - Enabled
|