Template:FMA Device Family Features Parameter list

From Teltonika Telematics Wiki

Green driving parameters

Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1890 Uint8 - 0 1 0 – Disable Scenario settings
1 – Enable
1891 Uint8 - 0 2 0 - disable Digital Output Control
1 - DOUT1
2 - DOUT2
1909 Uint8 - 0 1 0 - GPS Source
1 - Accelerometer
1892 Float 0.25 0.25 0.85 mG Max Acceleration Force
1893 Float 0.35 0.25 0.85 mG Max Braking Force
1894 Float 0.2 0.1 1.0 mG Max Cornering Force

Overspeeding scenario parameters


Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1895 Uint8 0 0 1 0 – Disable Scenario settings
1 – Enable
1896 Uint8 - 0 2 0 – None Digital Output control
1 – DOUT 1
2 – DOUT 2
1897 Uint16 - 0 260 km/h Max speed

Jamming scenario parameters


Parameter ID Parameter Type Recommended Value Value range Value Parameter name
Min Max
1898 Uint8 - 0 1 0 – Disable Scenario settings
1 – Enable
1899 Uint8 - 0 2 0 – None Digital Output control
1 – DOUT1
2 – DOUT2
1900 Uint8 - 0 2 0 – Low sensitivity (50 RSSI) Jamming sensitivity
1 – Medium sensitivity (30 RSSI)
2 – High sensitivity (10 RSSI)
1901 Uint16 60 0 65535 Seconds Jamming Timeout
1902 Uint16 0 0 65535 Seconds Jamming Pulse Duration

Immobilizer scenario parameters


Parameter ID Parameter Type Recommended value Value range Value Parameter name
Min Max
1903 Uint8 - 0 1 0 – Disable Scenario settings
1 – Enable
1904 Uint8 - 0 2 0 – Disable Digital Output Control
1 – DOUT1
2 – DOUT2

iButton read notification

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11704 Uint8_t 0 0 1 0 - Disabled DOUT control
1 - Enabled
11705 Uint16_t 200 100 50000 Milliseconds DOUT duration
11706 Uint8_t 0 0 1 0 - Disabled iButton notification list
1 - Enabled
11707 Uint8_t 0 0 1 0 - Disabled Depend on ignition
1 - Enabled

Trip scenario parameters


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
11800 Uint8 0 0 3 0 – Disable Scenario settings
1 – Low priority
2 – High priority
3 – Panic priority
11801 Uint8 1 0 1 0 – Disable Eventual records
1 – Enable
11802 Uint8 0 0 1 0 – Continuous Mode
1 – Between records
11803 Uint8 5 0 255 km/h Start speed
11804 Uint16 60 0 65535 Seconds Ignition off timeout
7031 Uint8 0 0 10 Phone number Send SMS to
8031 String "Trip" 0 160 Text Sms text

DOUT control via call scenario parameters


Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
12000 Uint8 0 0 2 (1 for FMB125) 0 – None Digital Output control
1 – DOUT 1
2 – DOUT 2
12001 Uint8 0 0 3 (1 for FMB125) 0 – None DOUT deactivation
1 – DIN 1
2 – DIN 2
3 – DIN 3
12002 Int32 5 0 2147483647 Seconds Duration timeout