FMC001 is a tracking terminal with GNSS and GSM connectivity, which is able to collect device coordinates and transfer them via GSM network to a server. This device is perfectly suitable for applications, which require the location acquirement of remote objects. It is important to mention that FMC001 has a standard OBD-II interface which lets you monitor basic vehicle parameters.
Monitorable basic vehicle parameters depend on vehicle mark and model.
Package contents
The FMC001 device is supplied to the customer in a cardboard box containing all the equipment that is necessary for operation. The package contains:
FMC001 device;
Top and bottom device cover parts;
OBD II power supply adapter.
Basic characteristics
GSM / GPRS / GNSS features:
Quectel EG91-EX, Teltonika TM2500;
GPRS Multi-Slot class 12 (Up to 240 kbps);
SMS (text, data);
Integrated GNSS receiver;
Up to -165 dBm GNSS receiver sensitivity.
Hardware features:
Built-in movement sensor;
Built-in Bluetooth 3.0;
Built-in Bluetooth 4.0;
Internal High Gain GNSS antenna;
Internal High Gain GSM antenna;
128 MB Flash (422 400 Records);
170 mAh Li-ion rechargeable 3.7 V battery.
Interface features:
Power supply: +10...+30 V;
CAN;
K-LINE;
USB port;
OBD II;
2 LEDs indicating device status.
Special features:
Fast position fix;
High Quality track even in high density urban canyon;
Small case;
2 LED status indication;
Real time tracking;
Smart data acquisition based on:
Time;
Speed;
Angle;
Distance;
Ignition or any other I/O event;
Sending acquired data via GPRS;
GPRS and SMS I/O events;
Virtual odometer;
Jamming detection;
Configurable using Secured SMS Commands.
Overvoltage protection.
Technical features
Part name
Physical specification
Navigation indication
LED
Modem indication
LED
OBD-II
Standard OBD-II connector
USB
Mini USB socket
Technical details
2 W max. Current consumption at 12 V
GPRS: max 50 mA Nominal: average 35 mA GPS sleep: average 12 mA Deep Sleep: average 4.5 mA
Battery charge current
Average: 140 mA Rated: 250 mA
Operating temperature (without battery)
-40 ... +85 °C
Storage temperature (without battery)
-40 ... +85 °C
Storage relative humidity
5 ... 95% (no condensation)
Internal fuse
3 A, 125 V
Device + case + battery weight
70 g
Dimension drawing:
Technical information about internal battery
Internal back-up battery
Battery voltage (V)
Nominal capacity (mAh)
Power (Wh)
Charge temperature (°C)
Discharge temperature (°C)
Storage temperature (°C)
Li-ion rechargeable battery
3.75~3.90
170
0.64 – 0.66
0 to +45
-20 to +60
-20 to +45 for 1 month -20 to +35 for 6 months
Batteries are covered by 6 month warranty support.
CAUTION: RISK OF EXPLOSION IF BATTERY IS REPLACED BY AN INCORRECT TYPE. DISPOSE OF USED BATTERIES ACCORDING TO THE INSTRUCTIONS.
Battery should not be disposed of into general household waste. Bring damaged or worn-out batteries to your local recycling center or dispose them into a battery recycle bin commonly found in supermarkets.