I/O properties are additional data sources which are recorded along with usual GPS data.

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2000 S8 1 0 3 0 – Disabled I/O#1 Priority
1 – Low
2 – High
3 – Panic
2003 S32 0 -2147483647 2147483647 I/O#1 High level
2002 S32 0 -2147483647 2147483647 I/O#1 Low level
2001 S8 3 0 5 0 – On Exit I/O#1 Event Generation Type
1 – On Entrance
2 – On Both
3 – Monitoring
4 – Hysteresis
5 – On Change
2004 S32 10 0 2592000 I/O#1 Averaging Constant

Other I/O property elements can be configured in same logic. All I/O element parameters are listed in the next table.

I/O Element Number I/O element parameters
Digital Input 1 2000-2004
Digital Input 2 2010-2014
Digital Input 3 2020-2024
Digital Input 4 2030-2034
Analog Input 1 2040-2044
Analog Input 2 2050-2054
Digital Output 1 2060-2064
Digital Output 2 2070-2074
GNSS PDOP 2080-2084
GNSS HDOP 2090-2094
External Voltage 2100-2104
GNSS Power 2110-2114
Movement Sensor 2120-2124
Odometer Value 2130-2134
GSM Operator 2140-2144
Speed 2150-2154
iButton ID 2160-2164
Data Mode 2170-2174
GSM Signal 2180-2184
Deep Sleep 2190-2194
Cell ID 2200-2204
Area Code 2210-2214
Dallas Temperature 1 2220-2224
Dallas Temperature 2 2230-2234
Dallas Temperature 3 2240-2244
Battery Voltage 2250-2254
Battery Current 2260-2264
Ignition 2270-2274
Network Type 2280-2284
Total odometer 2290-2294
Dallas Temperature ID 1 2250-2254
Dallas Temperature ID 2 2260-2264
Dallas Temperature ID 3 2270-2274
ICCID 2280-2284
IMSI 2290-2294
Ignition On Counter 2300-2304