Template:FMX640 and J1708

From Teltonika Telematics Wiki
Revision as of 17:39, 3 September 2020 by Sandra.Gasyte (talk | contribs) (Created page with "SAE J1708 is a standard used for serial communications between ECUs on a heavy-duty. The hardware utilized is RS-485 transceivers wired for open collector operation through th...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)

SAE J1708 is a standard used for serial communications between ECUs on a heavy-duty. The hardware utilized is RS-485 transceivers wired for open collector operation through the use of a pullup and pulldown of the separate data lines.

With FMX640, J1708 functionality is used to read vehicle's Fuel Level and Fuel consumption.

Because J1708 is not a CAN-BUS protocol, FMX640 CAN1 and CAN2 lines cannot be used to read J1708 information. FMX640 has a special J1708 Port, which utilizes an RJ9 4P4C connector.


Software Configuration of FMX640with J1708

Firmware version: 00.00.11 or above Configurator version: 0.13.35.29297 or above

J1708 configuration is done in the FMS IO Tab.

When J1708 is enabled as Fuel Level source, Fuel related data will be taken from the J1708 line, FMS Fuel data will be ignored.

Connection with Vehicle port

J1708 connector is not supported by all vehicles. Only VOLVO, RENAULT, and American truck manufacturers implement the J1708 connector.

Trucks utilizes Deutsch 9-PIN connector, which is used to connect FMX640 to J1708.

NOTE: Most of the Volvo trucks need an J1708 connection to be able to receive fuel level data