TFT100 First Start

From Wiki Knowledge Base | Teltonika GPS
Revision as of 15:08, 7 March 2023 by Martyna.D (talk | contribs) (Created page with "<b>{{{description|Small, professional and waterproof tracker for forklifts, E-mopeds and E-scooters with internal high gain GNSS/GSM antennas, Bluetooth, high capacity interna...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > E-Mobility Trackers > TFT100 > TFT100 First Start

Small, professional and waterproof tracker for forklifts, E-mopeds and E-scooters with internal high gain GNSS/GSM antennas, Bluetooth, high capacity internal Li-ion battery and 10-97 V power supply range.

TFT100 E-forklift tr.png


Pinout

TFT100 CAN PINOUT
TFT100 RS232 PINOUT
TFT100 RS485 PINOUT
TFT100 UART PINOUT
PIN COLOR CAN
PIN NAME
CAN
DESCRIPTION
RS232
PIN NAME
RS232
DESCRIPTION
RS485
PIN NAME
RS485
DESCRIPTION
UART
PIN NAME
UART
DESCRIPTION
Red VCC (10-97)V DC (+) Power supply (+10...97 V DC). VCC (10-97)V DC (+) Power supply (+10...97 V DC). VCC (10-97)V DC (+) Power supply (+10...97 V DC). VCC (10-97)V DC (+) Power supply (+10...97 V DC).
Black GND (-) Ground. GND (-) Ground. GND (-) Ground. GND (-) Ground.
Yellow 1WIRE POWER Power supply pin for Dallas 1-Wire devices 1WIRE POWER Power supply pin for Dallas 1-Wire devices 1WIRE POWER Power supply pin for Dallas 1-Wire devices 1WIRE POWER Power supply pin for Dallas 1-Wire devices
White/Green CAN-H CAN interface High. RS232-IN Input wire for RS232. RS485-B Signal wire B for RS485. UART-RX Input for data reception through UART.
White CAN-L CAN interface Low. RS232-OUT Output wire for RS232. RS485-A Signal wire A for RS485. UART-TX Output for data transmission through UART.
Grey AIN 2 /
DIN 2
Analog input, channel 2 / Digital input, channel 2. AIN 2 /
DIN 2
Analog input, channel 2 / Digital input, channel 2. AIN 2 /
DIN 2
Analog input, channel 2 / Digital input, channel 2. AIN 2 /
DIN 2
Analog input, channel 2 / Digital input, channel 2.
White/Orange DOUT 1 /
DIN 3
Digital output, channel 1 / Digital input, channel 3. DOUT 1 /
DIN 3
Digital output, channel 1 / Digital input, channel 3. DOUT 1 /
DIN 3
Digital output, channel 1 / Digital input, channel 3. DOUT 1 /
DIN 3
Digital output, channel 1 / Digital input, channel 3.
Violet DOUT 2 /
DIN 4
Digital output, channel 2 / Digital input, channel 4. DOUT 2 /
DIN 4
Digital output, channel 2 / Digital input, channel 4. DOUT 2 /
DIN 4
Digital output, channel 2 / Digital input, channel 4. DOUT 2 /
DIN 4
Digital output, channel 2 / Digital input, channel 4.
Green AIN 1 /
DIN 1
Analog input, channel 1 / Digital input, channel 1. AIN 1 /
DIN 1
Analog input, channel 1 / Digital input, channel 1. AIN 1 /
DIN 1
Analog input, channel 1 / Digital input, channel 1. AIN 1 /
DIN 1
Analog input, channel 1 / Digital input, channel 1.
Blue 1WIRE DATA Data channel for 1–Wire devices. 1WIRE DATA Data channel for 1–Wire devices. 1WIRE DATA Data channel for 1–Wire devices. 1WIRE DATA Data channel for 1–Wire devices.

Set up your device

How to insert Micro-SIM card

  1. Remove the bottom cover.
  2. Insert Micro-SIM card as shown with PIN request disabled or read Security info how to enter it later in Configurator. Make sure that Micro-SIM card cut-off corner is pointing forward to slot.
  3. Connect the battery as shown to the device.
  4. After configuration, attach device cover and put the screws back in.
  5. Device is ready to be connected.

Cover1.png Cover2.png Cover3.png
Cover4.png Cover5.png

Alert.png
Micro-SIM card insertion/removal must be performed when device is powered off – external voltage and battery are disconnected. Otherwise Micro-SIM card might be damaged or device will not detect it.


PC Connection (Windows)

  1. Power-up TFT100 with DC voltage 10 - 97V power supply using supplied power cable. LED’s should start blinking, see “LED behaviour description”.
  2. Connect device to computer using Micro-USB cable or Bluetooth® connection:
    • Using Micro-USB cable
    • Using Bluetooth®
      • TFT100 Bluetooth® is enabled by default. Turn on Bluetooth® on your PC, then select Add Bluetooth® or other device > Bluetooth®. Choose your device named – “TFT100_last_7_imei_digits”, without LE in the end. Enter default password 5555, press Connect and then select Done.
  3. You are now ready to use the device on your computer.

How to install USB drivers (Windows)

  1. Please download COM port drivers from here.
  2. Extract and run TeltonikaCOMDriver.exe.
  3. Click Next in driver installation window.
  4. In the following window click Install button.
  5. Setup will continue installing the driver and eventually the confirmation window will appear. Click Finish to complete the setup.

Configuration (Windows)

At first TFT100 device will have default factory settings set. These settings should be changed according to the user's needs.
Main configuration can be performed via Teltonika Configurator software. Get the latest TFT100 Configurator version from here. Configurator operates on Microsoft Windows OS and uses prerequisite MS .NET Framework. Make sure you have the correct version installed.

MS .NET requirements
Operating system MS .NET Framework version Version Link
  • Windows Vista
  • Windows 7
  • Windows 8.1
  • Windows 10
MS .NET Framework 4.6.2 32 and 64 bit .NET Framework

Downloaded Configurator will be in compressed archive. Extract it and launch Configurator.exe. After launch software language can be changed by clicking Language logo.png in the right bottom corner:

FMB Configurator languag.jpg

Configuration process begins by pressing on connected device:

TFT100-Configurator connect.png

After connection to Configurator Status window will be displayed: TFT100-Status-Screen.png


Various Status window tabs display information about GNSS, GSM, I/O, Maintenance and etc. TFT100 has one user editable profile, which can be loaded and saved to the device. After any modification of configuration the changes need to be saved to device using Save to device button. Main buttons offer following functionality:

  1. Load from device.png Load from device – loads configuration from device.
  2. Save to device.png Save to device – saves configuration to device.
  3. Load from file.png Load from file – loads configuration from file.
  4. Save to file.png Save to file – saves configuration to file.
  5. Firmware update.png Update firmware – updates firmware on device.
  6. Read records.png Read records – read records from device.
  7. Reboot device.png Reboot device – restarts device.
  8. Reset configuration.png Reset configuration – sets device configuration to default.

Most important configurator section is GPRS – where all your server and GPRS settings can be configured and Data Acquisition – where data acquiring parameters can be configured. More details about TFT100 configuration using Configurator can be found in the manual.

Quick SMS configuration

Default configuration has optimal parameters present to ensure best performance of track quality and data usage.
Quickly set up your device by sending this SMS command to it:

"  setparam 2001:APN;2002:APN_username;2003:APN_password;2004:Domain;2005:Port;2006:0"

GPRS settings:

  • 2001 – APN
  • 2002 – APN username (if there are no APN username, empty field should be left)
  • 2003 – APN password (if there are no APN password, empty field should be left)

Server settings:

  • 2004 – Domain
  • 2005 – Port
  • 2006 – Data sending protocol (0 – TCP, 1 – UDP)

Note: Before SMS text, two space symbols should be inserted.

IOS sms cfg.png
Default configuration settings
Movement and ignition detection:
Accelerometer.png Vehicle movement will be detected by accelerometer Ignition detection-2-2.png Ignition will be detected by vehicle power voltage between 13,2 – 30 V
Device makes a record On Moving if one of these events happen:
300s icon 2.png 300 seconds passes Angle 10 2.png Vehicle turns 10° degrees
Min distance.png Vehicle drives 100 meters Speed delta.png Speed difference between last coordinate and current position is greater than 10 km/h
Device makes a record On Stop if:
1h icon.png 1 hour passes while vehicle is stationary and ignition is off
Records sending to server:
120 s.png If device has made a record it is sent to the server every 120 seconds


After successful SMS configuration, TFT100 device will synchronize time and update records to configured server. Time intervals and default I/O elements can be changed by using Teltonika Configurator or SMS parameters.