Template:FM36M1 Electrical characteristics
From Wiki Knowledge Base | Teltonika GPS
Revision as of 01:42, 28 February 2020 by Sandra.Gasyte (talk | contribs) (→Electrical characteristics)
Electrical characteristics
Characteristic description | Value | |||
---|---|---|---|---|
Min. | Typ. | Max. | Unit | |
Supply Voltage: | ||||
Supply Voltage (Recommended Operating Conditions) | 10 | 30 | V | |
Drain current
(Digital Output ON, Recommended Operating Conditions) |
0.1 | 0.5 | µA | |
Static Drain-Source resistance (Digital Output ON) | 300 | mΩ | ||
Digital Input: | ||||
Input resistance (DIN1) | 15 | kΩ | ||
Input resistance (DIN2, AIN2) | 20 | kΩ | ||
Input resistance (AIN1) | 120 | kΩ | ||
Input voltage (Recommended Operating Conditions) | 0 | Supply voltage | V | |
Input Voltage threshold (DIN1) | 7.5 | V | ||
Input Voltage threshold (DIN2) | 2.5 | V | ||
Input Voltage threshold (AIN1, AIN2) | 3.5 | V | ||
Analog Input: | ||||
Input voltage (Recommended Operating Conditions), Range 1 | 0 | 10 | V | |
Input resistance, Range 1 | 120 | kΩ | ||
Measurement error | 0.47 | % | ||
Additional error | ±17.3 | mV | ||
Input Voltage (Recommended Operating Conditions), Range 2 | 0 | 30 | V | |
Input resistance, Range 2 | 150 | kΩ | ||
Measurement error | 1.01 | % | ||
Additional error | ±139 | 0 | mV |
Analog Input error margin can increase if temperature varies. |