Template:Teltonika FTXXX1 Data Sending Parameters ID

From Wiki Knowledge Base | Teltonika GPS


FTC AVL ID's consist of these parameters groups:

Permanent I/O elements





Eventual I/O elements


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
239 Ignition 1 Unsigned 0 1 - -

0 – Ignition Off
1 – Ignition On

Permanent I/O Elements
240 Movement 1 Unsigned 0 1 - -

0 – Movement Off
1 – Movement On

Permanent I/O elements
80 Data Mode 1 Unsigned 0 5 - -

0 – Home On Stop
1 – Home On Moving
2 – Roaming On Stop
3 – Roaming On Moving
4 – Unknown On Stop
5 – Unknown On Moving

Permanent I/O Elements
21 GSM Signal 1 Unsigned 0 5 - -

Value in range 1-5

Permanent I/O Elements
200 Sleep Mode 1 Unsigned 0 4 - -

0 - No Sleep
1 – GPS Sleep
2 – Deep Sleep
3 – Online Sleep
4 - Ultra Sleep

Permanent I/O Elements
69 GNSS Status 1 Unsigned 0 3 - -

0 - GNSS OFF
1 – GNSS ON with fix
2 - GNSS ON without fix
3 - GNSS sleep

Permanent I/O Elements
181 GNSS PDOP 2 Unsigned 0 500 0.1 Coefficient, calculation formula Permanent I/O Elements
182 GNSS HDOP 2 Unsigned 0 500 0.1 Coefficient, calculation formula Permanent I/O Elements
66 External Voltage 2 Unsigned 0 65535 0.001 V

Voltage

Permanent I/O elements
24 Speed 2 Unsigned 0 350 - km/h

GNSS Speed

Permanent I/O elements
205 GSM Cell ID 2 Unsigned 0 65535 - -

GSM base station ID

Permanent I/O elements
206 GSM Area Code 2 Unsigned 0 65535 - -

Location Area code (LAC), it depends on GSM operator. It provides unique number which assigned to a set of base GSM stations.

Permanent I/O elements
67 Battery Voltage 2 Unsigned 0 65535 0.001 V

Voltage

Permanent I/O elements
68 Battery Current 2 Unsigned 0 65535 0.001 A

Current

Permanent I/O elements
241 Active GSM Operator 4 Unsigned 0 4294967295 - -

Currently used GSM Operator code

Permanent I/O elements
199 Trip Odometer 4 Unsigned 0 2147483647 - m

Trip Odometer value

Permanent I/O elements
16 Total Odometer 4 Unsigned 0 2147483647 - -

Total Odometer value in meters

Permanent I/O elements
1 Digital Input 1 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
9 Analog Input 1 2 Unsigned 0 65535 0.001 V

Voltage

Permanent I/O elements

179 Digital Output 1 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
250 Trip 1 Unsigned 0 1 - -

0 – trip stop
1 – trip start
From 01.00.24 fw version available with BT app new values:
2 – Business Status
3 – Private Status
4-9 – Custom Statuses

Eventual I/O elements
255 Over Speeding 1 Unsigned 0 255 - km/h

At over speeding start km/h, at over speeding end km/h

Eventual I/O elements
257 Crash trace data Variable HEX 0 1200 - - Crash trace data

FTXXXX [Expand] FTC921
FTC961
FTC881

251 Idling 1 Unsigned 0 1 - -

0 – moving
1 – idling

FTXXXX [Expand] FTC921
FTC961
FTC881

Eventual I/O elements
253 Green driving type 1 Unsigned 1 3 - -

1 – harsh acceleration
2 – harsh braking
3 – harsh cornering

FTXXXX [Expand] FTC921
FTC961
FTC881

Eventual I/O elements