FMM640 Custom scenario
Revision as of 12:45, 2 September 2019 by Aurimas.vanagas (talk | contribs) (Protected "FMM640 Custom scenario" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite)))
FMM640 devices has „Custom scenarios“ functionality, which is designed to create four different instances for DOUT control. Scenario has three different possible sources, which logic is taken from „I/O“ element section and if triggered will create an event or / and activate the selected DOUT.
Each of the four scenarios can be selected to control:
- DOUT1
- DOUT2
- DOUT3
- DOUT4 (Mode must be selected)
The event will be generated according to the "I/O" element's logic, but the priority of "Custom scenario" event does not depend on the "I/O" element settings and can be selected in the scenario section.