Template:FMX125 RS-232 and RS-485

Revision as of 11:44, 11 August 2021 by Mantas.Kraujelis (talk | contribs) (Created page with " ==RS-485 interface== RS-485 supports only half-duplex communication, which means data is transferred only one way at a time.<br />When activated RS-485 driver chip draws con...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)

RS-485 interface

RS-485 supports only half-duplex communication, which means data is transferred only one way at a time.
When activated RS-485 driver chip draws constant 30mA current, when entering Sleep or Deep sleep RS-485 will be powered off.
RS-485 connection diagram is shown below.

RS-485 modes

  • RS-485 transmit (FMB log) mode:

RS-485 prints FMB device log and does not respond to commands.

  • RS-485 transmit (GNSS NMEA) mode:

RS485 MODES.gif RS-485 prints GNSS NMEA log and does not respond to commands.

  • RS-485 receive (LLS) mode:

This mode supports up to five LLS fuel level sensors each of which has a receiver ID.

  • RS-485 TCP (ASCII/Binary) modes:

In TCP ASCII/Binary mode a link with an external device using text messages can be established. In TCP ASCII/Binary mode all data received from external device through RS-485 is sent directly to server (if link is currently active). Data is encapsulated in codec 12 format.

Fmb125 rs485 block.png


RS-485 TCP Binary settings


RS-485 TCP BINARY.gif

TCP Binary has a setting Prefix. It is possible to set Prefix 1, Prefix 2 or Prefix 3. These prefixes can be used seperately or in unison. To configure this setting a value from 0 to 255 in decimal has to be entered. Device will convert this value to HEX and compare the 1st, 2nd or 3rd byte from incoming data. If the values do not match, device will not accept incoming data.

Example:
Incoming packet through RS232/RS485 using TCP Binary/TCP Binary Buffered mode - 50 72 65 66 69 78 20 57 6f 72 6b 69 6e 67

  • If Prefix 1 is set to 80 in decimal, it is equal to 50 in HEX.
    • FMB device will then check the 1st byte of incoming data and compare to the set Prefix 1.
  • If Prefix 2 is set to 114 in decimal, it is equal to 72 in HEX.
    • FMB device will then check the 2nd byte of incoming data and compare to the set Prefix 2.
  • If Prefix 3 is set to 101 in decimal, it is equal to 65 in HEX.
    • FMB device will then check the 3rd byte of incoming data and compare to the set Prefix 3.

When values match, data will be accepted and saved to Buffer (using TCP Binary Buffered mode) or sent to server (using TCP Binary mode).

Incoming packet through RS232/RS485 using TCP Binary/TCP Binary Buffered mode - 50 0 65 66 69 78 20 57 6f 72 6b 69 6e 67

  • If Prefix 1 is set to 80 in decimal, it is equal to 50 in HEX.
    • FMB device will then check the 1st byte of incoming data and compare to the set Prefix 1.
  • If Prefix 2 is set to 114 in decimal, it is equal to 72 in HEX.
    • FMB device will then check the 2nd byte 0 of incoming data and compare to the set Prefix 2.

Since Prefix 2 does not match incoming 2nd byte, data will not be accepted.

RS-485 CMD ID

This parameter is used when is sending RS232/RS485 packet to a server, it overrides command type value in Codec12/Codec13 with user defined CMD ID value (1 - 14). behavior when it receives different CMD ID (Type) values in GPRS packet from server:

CMD ID Functionality
5 Parse Codec12/Codec14 packet from the server
7 Forward packet meant for Garmin system
14 Forward packet to external device via uart using RS232/RS485
16 Forward packet to paired Bluetooth device

RS-232-CMD1.gif

RS-232 Interface

RS-232 supports full-duplex communication which means the data can be both sent and received at the same time as they use separate transmission lines. Most of the modes are the same as for RS-485.

RS-232 connection diagram is shown on the figure above.

RS-232 modes

Log mode, NMEA, LLS, TCP ASCII and TCP Binary modes are identical to those of RS-485. In RS-232 LLS mode only one LLS fuel level sensor can be connected. Additionally TCP ASCII Buffered and TCP Binary Buffered modes are available.

  • RS-232 LCD mode:

In this mode, the user is able to communicate with the server through the terminal. A link between the FMB device and the server has to be established for this mode to function properly.

To communicate from terminal to server - in terminal send command "WT^W your text here"

To communicate with server to terminal - send "#DO DAT=you text here" packet in Codec12 protocol


  • RS-232 RFID HID/RFID MF7 mode:

The difference between RFID HID Mode and RFID MF7 Mode is that in RFID MF7 Mode understands RFID messages that are in hexadecimal text format and RFID HID Mode interpretes messages that are in binary format. The type of RFID message sent to depends on the RFID reader. For example, RFID MF7 mode message looks like "$aa$02$03$04$17$89$00$01" while HID mode message is of following format: "1213141519".

The selected mode has to correspond to the RFID reader's mode. RS-232 MODES.gif Please contact your local sales representative for more information about RFID IDs and devices.


  • RS-232 Garmin mode:

Garmin provides a Fleet Management Interface Tool Kit, once is connected to the navigator it enables the driver to have a "screen" in their vehicle for real-time navigation and messaging, and offers job dispatch capabilities to help them be more efficient.
and Garmin operational diagram is shown on the figure below.

Fmb125 garmin block.png
  • RS-232 TCP Binary/TCP ASCII mode:

In TCP ASCII/Binary mode all data received from external device is sent directly to server. Data is encapsulated in codec 12 format. TCP Binary Mode has a delay of 30 ms, if no data is received for 30 ms, data is sent to the server. TCP ASCII mode waits for the End of Line (EOL) character (0x0D0A, \r\n) to pack data and send it to the server

  • RS-232 TCP Binary Buffered/TCP ASCII Buffered mode:

TCP ASCII Buffered and TCP Binary Buffered modes are used to collect data from RS232 and save it in buffer if there is no link with server and data cannot be sent immediately. When link is established and there is data to transmit, then RS232 data from buffer is transmitted after all records are sent. Data is sent in codec 13 protocol. Note. That in TCP ASCII and TCP Binary modes device sends data from external device only to main server. In Buffered modes – to both main and backup/duplicate servers. Message timestamp: Message Timestamp parameter is used to determine if it is necessary to include timestamp in RS232 TCP packet when sending to server. If parameter is enabled, then Codec 13 is used for data sending. Otherwise, Codec 12 is used.


RS-232 TCP Binary settings

RS-232 TCP BINARY SETTINGS.gif

TCP Binary has a setting Prefix. It is possible to set Prefix 1, Prefix 2 or Prefix 3. These prefixes can be used seperately or in unison. To configure this setting a value from 0 to 255 in decimal has to be entered. Device will convert this value to HEX and compare the 1st, 2nd or 3rd byte from incoming data. If the values do not match, device will not accept incoming data.

Example:
Incoming packet through RS232/RS485 using TCP Binary/TCP Binary Buffered mode - 50 72 65 66 69 78 20 57 6f 72 6b 69 6e 67

  • If Prefix 1 is set to 80 in decimal, it is equal to 50 in HEX.
    • FMB device will then check the 1st byte of incoming data and compare to the set Prefix 1.
  • If Prefix 2 is set to 114 in decimal, it is equal to 72 in HEX.
    • FMB device will then check the 2nd byte of incoming data and compare to the set Prefix 2.
  • If Prefix 3 is set to 101 in decimal, it is equal to 65 in HEX.
    • FMB device will then check the 3rd byte of incoming data and compare to the set Prefix 3.

When values match, data will be accepted and saved to Buffer (using TCP Binary Buffered mode) or sent to server (using TCP Binary mode).

Incoming packet through RS232/RS485 using TCP Binary/TCP Binary Buffered mode - 50 0 65 66 69 78 20 57 6f 72 6b 69 6e 67

  • If Prefix 1 is set to 80 in decimal, it is equal to 50 in HEX.
    • FMB device will then check the 1st byte of incoming data and compare to the set Prefix 1.
  • If Prefix 2 is set to 114 in decimal, it is equal to 72 in HEX.
    • FMB device will then check the 2nd byte 0 of incoming data and compare to the set Prefix 2.

Since Prefix 2 does not match incoming 2nd byte, data will not be accepted.

Codec 12/13 Packet Merge

This additional option configures the device to merge RS-232 records into a single packet instead of sending many separate packets. This functionality only affects TCP Binary Buffered or TCP Ascii Buffered RS232 modes. When enabled, the device will merge saved RS-232 records together into a single data packet until it is able to send it to the server.
This optimizes RS-232 data sending by not having to send each RS-232 record separately. If the amount of saved RS-232 data exceeds the maximum 4 bytes of data in one Codec 12 packet, the device will start saving incoming RS-232 data into a new record.

Packet merge.png

RS-232 CMD ID

This parameter is used when is sending RS232/RS485 packet to a server, it overrides command type value in Codec12/Codec13 with user defined CMD ID value (1 - 14). behavior when it receives different CMD ID (Type) values in GPRS packet from server:

CMD ID Functionality
5 Parse Codec12/Codec14 packet from the server
7 Forward packet meant for Garmin system
14 Forward packet to external device via uart using RS232/RS485
16 Forward packet to paired Bluetooth device

Garmin protocols

The following is a list of protocols supported and the corresponding list of features/benefits. can fully support Fleet Management Interface (FMI) versions up to 2.1. Other or higher versions may be supported, but Teltonika is not responsible for the changes made by Garmin, which may affect the function of and Garmin products. For more information about Garmin products and FMI versions, please refer to https://www.garmin.com/en-US/fleet-ready-navigators/. Notice that some Garmin products use different connection cables than others.

Standard protocols

Text Message Protocol:

  • Allows text messages sent to the device to be displayed in "inbox" on navigation unit;
  • Garmin can provide a confirmation that message was read;
  • Garmin can also provide a yes/no box below the text of the message to enable a quicker response;
  • Messages can be up to 199 characters long;
  • Messages can also be generated from device and sent to dispatcher/office;
  • Messages received will be notified to driver through a pop-up alert on Garmin screen;
  • Garmin provides a "virtual keyboard" for text communication.

Stop (Destination) Protocol:

  • Garmin can display a list of Stops/Jobs reported to the device in a separate category called "My Stops";
  • Driver has ability to navigate directly to Stop from the list;
  • Garmin can provide status of a current Stop in progress;
  • Garmin can indicate whether the driver has stopped at the location;
  • Garmin can inform how far the driver has progressed through the list of Stops;
  • Garmin can provide confirmation that the driver has received a particular Stop, familiarized himself/herself with its details or removed it from the list;
  • Can provide confirmation that a Stop has been reached.

Estimated Time of Arrival Protocol:

  • Dispatcher/office can request the ETA of the current Stop/job in progress;
  • Garmin can notify about the actual time of arrival as well as the distance remaining to a Stop.

Auto-Arrival at Stop Protocol:

  • This feature is used to tell Garmin PND to automatically detect that it has arrived at a Stop and then to prompt the driver if he/she would like to mark the Stop as done and begin navigating to a next Stop on the list;
  • Auto-arrival can be determined by how long the unit is stopped close to the destination (in the case driver has to park and walk) or by how close the unit needs to be to the destination before the Auto-arrival feature is activated.

Data Deletion Protocol:

  • Dispatcher/office has the ability to wipe clean the data on Garmin PND;
  • It allows to clean messages in inbox and remove stops.

Enhanced protocols

Canned Responses/Messages:

  • Fleet managers can communicate by sending up to 200 "canned" responses from the server to be stored directly on Garmin devices;
  • Up to 50 of these canned responses can be utilized for any given scenarios;
  • Drivers can store up to 120 canned messages, eliminating the need to type while driving.

Status Protocol:

  • Up-to-the-minute communications that allow drivers to automatically send status updates;
  • Driver's units can store up to 16 status indicators such as start/stop shift, on/off break etc.

Supported features on TAVL client application

TAVL client application lets user use the following features of Garmin FMI:

  • Text messaging;
  • Destination message;
  • ETA request.

Text messaging

Text messaging feature lets user communicate with the driver (user that operates Garmin device) by sending text messages via GPRS.

Destination message

Destination message is used to inform the driver of a new destination. When Garmin device receives a destination message from the server it displays it as a Stop to the driver and also gives the driver an ability to start navigating to the Stop location. New destination in TAVL client is represented as a Geozone so a new Geozone (as destination) has to be created first.

ETA request message

Estimated Time of Arrival request message is used when user wants to know an expected arrival time to currently active destination and the distance (in meters) from current object location to the destination.