Template:FMB OBD Device Family Features Parameter list
Revision as of 11:46, 4 July 2022 by BaronenasT (talk | contribs) (Created page with " ===Green driving parameters=== {| class="wikitable" |+ ! rowspan="2" style="width: 150px; background: black; color: white;" |'''Parameter ID''' ! rowspan="2" style="width: 15...")
Green driving parameters
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
11000 | Uint8 | 0 | 0 | 3 | 0 – Disable | Scenario settings |
1 – Low priority | ||||||
2 – High priority | ||||||
3 – Panic priority | ||||||
11004 | Uint8 | 2.5 | 0.5 | 10 | m/s2 | Max acceleration |
11005 | Uint8 | 2.7 | 0.5 | 10 | m/s2 | Max braking |
11006 | Uint8 | 3.4 | 0.5 | 10 | m/s2 | Max cornering |
11007 | Uint8 | 0 | 0 | 1 | 0 – GPS | Source |
1 – Accelerometer | ||||||
11008 | uint8 | 0 | 0 | 1 | Enable/Disable | Duration |
11003 | Uint8 | 0 | 0 | 2 (1 for FMB125) | 0 – None | Output control |
1 – DOUT 1 | ||||||
2 – DOUT 2 | ||||||
11001 | Int32 | 200 | 0 | 2147483647 | Milliseconds | DOUT ON duration |
11002 | Int32 | 200 | 0 | 2147483647 | Milliseconds | DOUT OFF duration |
7034 | Uint8 | 0 | 0 | 10 | Phone number | Send SMS to |
8034 | String | "Green Driving" | 0 | 160 | Text | Sms text |
Overspeeding scenario parameters
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
11100 | Uint8 | 0 | 0 | 3 | 0 – Disable | Scenario settings |
1 – Low priority | ||||||
2 – High priority | ||||||
3 – Panic priority | ||||||
11104 | Uint16 | 90 | 0 | 260 | km/h | Max speed |
11103 | Uint8 | 0 | 0 | 2 (1 for FMB125) | 0 – None | Output control |
1 – DOUT 1 | ||||||
2 – DOUT 2 | ||||||
11101 | Int32 | 200 | 0 | 2147483647 | Milliseconds | DOUT ON duration |
11102 | Int32 | 200 | 0 | 2147483647 | Milliseconds | DOUT OFF duration |
7032 | Uint8 | 0 | 0 | 10 | Phone number | Send SMS to |
8032 | String | "Overspeeding" | 0 | 160 | Text | Sms text |
Jamming scenario parameters
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
11300 | Uint8 | 0 | 0 | 3 | 0 – Disable | Scenario settings |
1 – Low priority | ||||||
2 – High priority | ||||||
3 – Panic priority | ||||||
11303 | Uint8 | 1 | 0 | 1 | 0 – Disable | Eventual records |
1 – Enable | ||||||
11304 | Uint8 | 0 | 0 | 2 (1 for FMB125) | 0 – None | Output control |
1 – DOUT1 | ||||||
2 – DOUT2 | ||||||
11301 | Int32 | 200 | 0 | 2147483647 | Milliseconds | DOUT ON duration |
11302 | Int32 | 200 | 0 | 2147483647 | Milliseconds | DOUT OFF duration |
11305 | Uint16 | 60 | 0 | 65535 | Seconds | Timeout |