Template:SAS device Parameter list - GPRS

Revision as of 12:29, 8 March 2023 by Martyna.D (talk | contribs) (Protected "Template:SAS device Parameter list - GPRS" ([Edit=Allow only administrators] (indefinite) [Move=Allow only administrators] (indefinite)))

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)

GPRS

GPRS Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2000 Uint8 1 0 1 0 – Disable GPRS context
1 – Enable
2001 Char "" 0 32 String APN
2002 Char "" 0 32 String APN username
2003 Char "" 0 32 String APN password
2016 Uint8 0 0 1 0 - Normal (PAP) -
1 - Secured (CHAP)

Server Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2004 Char "" 0 55 String Domain
2005 Uint16 0 0 65535 Number Port
2006 Uint8 0 0 1 0 – TCP Protocol
1 – UDP
2020 Uint8 0 0 1 0 – None Encryption
1 – TLS/DTLS

Second Server Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
2010 Uint8 0 0 2 0 - Disable Backup Server Mode
1 - Backup
2 - Duplicate
2007 Char "" 0 55 String Backup Server Domain
2008 Uint16 0 0 65535 Number Backup Server Port
2009 Uint8 0 0 1 0 - TCP Backup Server Protocol
1 - UDP
2021 Uint8 0 0 1 0 – None Encryption
1 – TLS/DTLS

Records Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
1000 Uint32 30 30 259200 Seconds Open link timeout
1001 Uint16 30 5 300 Seconds Response timeout
1003 Uint16 0 0 30 Seconds Network Ping Timeout
1002 Uint8 1 0 1 0 – Newest Sort by
1 – Oldest
1004 Uint8 1 0 1 0 – TCP/IP ACK Type
1 – AVL
1008 Uint8 0 0 1 0 – Disable Permanent Link
1 – Enable

FOTA WEB Settings

Parameter ID Parameter Type Default value Value range Value Parameter name
Min Max
13003 Uint8 1 0 1 0 - Disable FOTA WEB Status
1 – Enable
13000 Char fm.teltonika.lt 0 55 String FOTA WEB Domain
13001 Uint16 5000 0 65535 Number FOTA WEB Port
13002 Uint16 720 30 65535 Minutes FOTA WEB Period