Mode
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
150 | Uint16 | 0 | 0 | 1 | 0 – Disable | External UART Mode |
1 – RS485 |
RS485 Settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
160 | Uint16 | 0 | 0 | 1 | 0 – Log Mode | RS485 Mode |
1 – NMEA | ||||||
2 – TCP Ascii | ||||||
3 – TCP Binary | ||||||
4 – SuperSoco | ||||||
153 | Uint16 | 1 | 0 | 1 | 0 – Default | Parity |
1 – None | ||||||
2 – Odd | ||||||
3 – Even | ||||||
161 | Uint16 | 0 | 0 | 1 | 0 – Default | Baudrate |
1 – 9600 | ||||||
2 – 14400 | ||||||
3 – 19200 | ||||||
4 – 38400 | ||||||
5 – 57600 | ||||||
6 – 115200 | ||||||
158 | Uint16 | 0 | 0 | 1 | 0 – Disable | Message Timestamp |
1 – Enable |
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | ||
---|---|---|---|---|---|---|---|
Min | Max | ||||||
154 | Uint8 | 0 | 0 | 255 | - | Prefix 1 | TCP Binary Mode Settings |
155 | Uint8 | 0 | 0 | 255 | - | Prefix 2 | |
156 | Uint8 | 0 | 0 | 255 | - | Prefix 3 |
RS485 I/O
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
252 | Uint8 | 90 | 1 | 255 | centimeters | Wheel diameter |
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | Input name | RS485 Protocol | |
---|---|---|---|---|---|---|---|---|
Min | Max | |||||||
52320 | Uint8 | 0 | 0 | 3 | 0 – None | Priority | Power | Super Soco |
1 – Low | ||||||||
2 – High | ||||||||
3 – Panic | ||||||||
52323 | Uint8 | 0 | 0 | 3 | - | Low Level | ||
52322 | Uint8 | 0 | 0 | 3 | - | High Level | ||
52324 | Uint8 | 0 | 0 | 2 | 0 – No | Event Only | ||
1 – Yes | ||||||||
2 – Crash | ||||||||
52321 | Uint8 | 3 | 0 | 6 | 0 – On Exit | Operand | ||
1 – On Entrance | ||||||||
2 – On Both | ||||||||
3 – Monitoring | ||||||||
4 – On Hysteresis | ||||||||
5 – On Change | ||||||||
6 – On Delta Change | ||||||||
7435 | Uint8 | 0 | 0 | 10 | Predefined Number | Send SMS To | ||
8435 | String | Power | 0 | 160 | Predefined Number | SMS Text | ||
52330 | Uint8 | 0 | 0 | 3 | 0 – None | Priority | Current Trip Range | Super Soco |
1 – Low | ||||||||
2 – High | ||||||||
3 – Panic | ||||||||
52333 | Uint8 | 0 | 0 | Meterse | Low Level | |||
52332 | Uint8 | 0 | 0 | Meters | High Level | |||
52334 | Uint8 | 0 | 0 | 2 | 0 – No | Event Only | ||
1 – Yes | ||||||||
2 – Crash | ||||||||
52331 | Uint8 | 3 | 0 | 6 | 0 – On Exit | Operand | ||
1 – On Entrance | ||||||||
2 – On Both | ||||||||
3 – Monitoring | ||||||||
4 – On Hysteresis | ||||||||
5 – On Change | ||||||||
6 – On Delta Change | ||||||||
7436 | Uint8 | 0 | 0 | 10 | Predefined Number | Send SMS To | ||
8436 | String | Current trip range | 0 | 160 | Predefined Number | SMS Text | ||
52340 | Uint8 | 0 | 0 | 3 | 0 – None | Priority | Total trip Range | Super Soco |
1 – Low | ||||||||
2 – High | ||||||||
3 – Panic | ||||||||
52343 | Uint8 | 0 | 0 | Meters | Low Level | |||
52342 | Uint8 | 0 | 0 | Meters | High Level | |||
52344 | Uint8 | 0 | 0 | 2 | 0 – No | Event Only | ||
1 – Yes | ||||||||
2 – Crash | ||||||||
52341 | Uint8 | 3 | 0 | 6 | 0 – On Exit | Operand | ||
1 – On Entrance | ||||||||
2 – On Both | ||||||||
3 – Monitoring | ||||||||
4 – On Hysteresis | ||||||||
5 – On Change | ||||||||
6 – On Delta Change | ||||||||
7437 | Uint8 | 0 | 0 | 10 | Predefined Number | Send SMS To | ||
8437 | String | Total Trip Range | 0 | 160 | Predefined Number | SMS Text | ||
52350 | Uint8 | 0 | 0 | 3 | 0 – None | Priority | Battery Capacity | Super Soco |
1 – Low | ||||||||
2 – High | ||||||||
3 – Panic | ||||||||
52353 | Uint8 | 0 | 0 | 255 | % | Low Level | ||
52352 | Uint8 | 0 | 0 | 255 | % | High Level | ||
52354 | Uint8 | 0 | 0 | 2 | 0 – No | Event Only | ||
1 – Yes | ||||||||
2 – Crash | ||||||||
52351 | Uint8 | 3 | 0 | 6 | 0 – On Exit | Operand | ||
1 – On Entrance | ||||||||
2 – On Both | ||||||||
3 – Monitoring | ||||||||
4 – On Hysteresis | ||||||||
5 – On Change | ||||||||
6 – On Delta Change | ||||||||
7438 | Uint8 | 0 | 0 | 10 | Predefined Number | Send SMS To | ||
8438 | String | Voltage | 0 | 160 | Predefined Number | SMS Text | ||
52360 | Uint8 | 0 | 0 | 3 | 0 – None | Priority | Low Voltage | Super Soco |
1 – Low | ||||||||
2 – High | ||||||||
3 – Panic | ||||||||
52363 | Uint8 | 0 | 0 | 0 | - | Low Level | ||
52362 | Uint8 | 0 | 0 | 1 | - | High Level | ||
52364 | Uint8 | 0 | 0 | 2 | 0 – No | Event Only | ||
1 – Yes | ||||||||
2 – Crash | ||||||||
52361 | Uint8 | 3 | 0 | 6 | 0 – On Exit | Operand | ||
1 – On Entrance | ||||||||
2 – On Both | ||||||||
3 – Monitoring | ||||||||
4 – On Hysteresis | ||||||||
5 – On Change | ||||||||
6 – On Delta Change | ||||||||
7439 | Uint8 | 0 | 0 | 10 | Predefined Number | Send SMS To | ||
8439 | String | Low Voltage | 0 | 160 | Predefined Number | SMS Text | ||
52370 | Uint8 | 0 | 0 | 3 | 0 – None | Priority | High temperature | Super Soco |
1 – Low | ||||||||
2 – High | ||||||||
3 – Panic | ||||||||
52373 | Uint8 | 0 | 0 | 0 | - | Low Level | ||
52372 | Uint8 | 0 | 0 | 1 | - | High Level | ||
52374 | Uint8 | 0 | 0 | 2 | 0 – No | Event Only | ||
1 – Yes | ||||||||
2 – Crash | ||||||||
52371 | Uint8 | 3 | 0 | 6 | 0 – On Exit | Operand | ||
1 – On Entrance | ||||||||
2 – On Both | ||||||||
3 – Monitoring | ||||||||
4 – On Hysteresis | ||||||||
5 – On Change | ||||||||
6 – On Delta Change | ||||||||
7440 | Uint8 | 0 | 0 | 10 | Predefined Number | Send SMS To | ||
8440 | String | High Temperature | 0 | 160 | Predefined Number | SMS Text | ||
52380 | Uint8 | 0 | 0 | 3 | 0 – None | Priority | Upload Time | Super Soco |
1 – Low | ||||||||
2 – High | ||||||||
3 – Panic | ||||||||
52383 | Uint8 | 0 | 0 | 0 | - | Low Level | ||
52382 | Uint8 | 0 | 0 | 1 | - | High Level | ||
52384 | Uint8 | 0 | 0 | 2 | 0 – No | Event Only | ||
1 – Yes | ||||||||
2 – Crash | ||||||||
52381 | Uint8 | 3 | 0 | 6 | 0 – On Exit | Operand | ||
1 – On Entrance | ||||||||
2 – On Both | ||||||||
3 – Monitoring | ||||||||
4 – On Hysteresis | ||||||||
5 – On Change | ||||||||
6 – On Delta Change | ||||||||
7441 | Uint8 | 0 | 0 | 10 | Predefined Number | Send SMS To | ||
8441 | String | Upload Time | 0 | 160 | Predefined Number | SMS Text | ||
52390 | Uint8 | 0 | 0 | 3 | 0 – None | Priority | Moving Abnormal | Super Soco |
1 – Low | ||||||||
2 – High | ||||||||
3 – Panic | ||||||||
52393 | Uint8 | 0 | 0 | 0 | - | Low Level | ||
52392 | Uint8 | 0 | 0 | 1 | - | High Level | ||
52394 | Uint8 | 0 | 0 | 2 | 0 – No | Event Only | ||
1 – Yes | ||||||||
2 – Crash | ||||||||
52391 | Uint8 | 3 | 0 | 6 | 0 – On Exit | Operand | ||
1 – On Entrance | ||||||||
2 – On Both | ||||||||
3 – Monitoring | ||||||||
4 – On Hysteresis | ||||||||
5 – On Change | ||||||||
6 – On Delta Change | ||||||||
7442 | Uint8 | 0 | 0 | 10 | Predefined Number | Send SMS To | ||
8442 | String | Moving Abnormal | 0 | 160 | Predefined Number | SMS Text | ||
52400 | Uint8 | 0 | 0 | 3 | 0 – None | Priority | Range km | Super Soco |
1 – Low | ||||||||
2 – High | ||||||||
3 – Panic | ||||||||
52403 | Uint8 | 0 | 0 | 65535 | Kilometers | Low Level | ||
52402 | Uint8 | 0 | 0 | 65535 | Kilometers | High Level | ||
52404 | Uint8 | 0 | 0 | 2 | 0 – No | Event Only | ||
1 – Yes | ||||||||
2 – Crash | ||||||||
52401 | Uint8 | 3 | 0 | 6 | 0 – On Exit | Operand | ||
1 – On Entrance | ||||||||
2 – On Both | ||||||||
3 – Monitoring | ||||||||
4 – On Hysteresis | ||||||||
5 – On Change | ||||||||
6 – On Delta Change | ||||||||
7443 | Uint8 | 0 | 0 | 10 | Predefined Number | Send SMS To | ||
8443 | String | Range km | 0 | 160 | Predefined Number | SMS Text | ||
52410 | Uint8 | 0 | 0 | 3 | 0 – None | Priority | Lock Status | Super Soco |
1 – Low | ||||||||
2 – High | ||||||||
3 – Panic | ||||||||
52413 | Uint8 | 0 | 0 | 0 | - | Low Level | ||
52412 | Uint8 | 0 | 0 | 1 | - | High Level | ||
52414 | Uint8 | 0 | 0 | 2 | 0 – No | Event Only | ||
1 – Yes | ||||||||
2 – Crash | ||||||||
52411 | Uint8 | 3 | 0 | 6 | 0 – On Exit | Operand | ||
1 – On Entrance | ||||||||
2 – On Both | ||||||||
3 – Monitoring | ||||||||
4 – On Hysteresis | ||||||||
5 – On Change | ||||||||
6 – On Delta Change | ||||||||
7444 | Uint8 | 0 | 0 | 10 | Predefined Number | Send SMS To | ||
8444 | String | Lock Status | 0 | 160 | Predefined Number | SMS Text | ||
52420 | Uint8 | 0 | 0 | 3 | 0 – None | Priority | Vehicle FW version | Super Soco |
1 – Low | ||||||||
2 – High | ||||||||
3 – Panic | ||||||||
52423 | Uint8 | 0 | 0 | 65535 | - | Low Level | ||
52422 | Uint8 | 0 | 0 | 65535 | - | High Level | ||
52424 | Uint8 | 0 | 0 | 2 | 0 – No | Event Only | ||
1 – Yes | ||||||||
2 – Crash | ||||||||
52421 | Uint8 | 3 | 0 | 6 | 0 – On Exit | Operand | ||
1 – On Entrance | ||||||||
2 – On Both | ||||||||
3 – Monitoring | ||||||||
4 – On Hysteresis | ||||||||
5 – On Change | ||||||||
6 – On Delta Change | ||||||||
7445 | Uint8 | 0 | 0 | 10 | Predefined Number | Send SMS To | ||
8445 | String | Vehicle FW version | 0 | 160 | Predefined Number | SMS Text | ||
52430 | Uint8 | 0 | 0 | 3 | 0 – None | Priority | Total Range | Super Soco |
1 – Low | ||||||||
2 – High | ||||||||
3 – Panic | ||||||||
52433 | Uint8 | 0 | 0 | Kilometers | Low Level | |||
52432 | Uint8 | 0 | 0 | Kilometers | High Level | |||
52434 | Uint8 | 0 | 0 | 2 | 0 – No | Event Only | ||
1 – Yes | ||||||||
2 – Crash | ||||||||
52431 | Uint8 | 3 | 0 | 6 | 0 – On Exit | Operand | ||
1 – On Entrance | ||||||||
2 – On Both | ||||||||
3 – Monitoring | ||||||||
4 – On Hysteresis | ||||||||
5 – On Change | ||||||||
6 – On Delta Change | ||||||||
7446 | Uint8 | 0 | 0 | 10 | Predefined Number | Send SMS To | ||
8446 | String | Total Range | 0 | 160 | Predefined Number | SMS Text | ||
52440 | Uint8 | 0 | 0 | 3 | 0 – None | Priority | Battery Capacity | Super Soco |
1 – Low | ||||||||
2 – High | ||||||||
3 – Panic | ||||||||
52443 | Uint8 | 0 | 0 | kW*h | Low Level | |||
52442 | Uint8 | 0 | 0 | kW*h | High Level | |||
52444 | Uint8 | 0 | 0 | 2 | 0 – No | Event Only | ||
1 – Yes | ||||||||
2 – Crash | ||||||||
52441 | Uint8 | 3 | 0 | 6 | 0 – On Exit | Operand | ||
1 – On Entrance | ||||||||
2 – On Both | ||||||||
3 – Monitoring | ||||||||
4 – On Hysteresis | ||||||||
5 – On Change | ||||||||
6 – On Delta Change | ||||||||
7447 | Uint8 | 0 | 0 | 10 | Predefined Number | Send SMS To | ||
8447 | String | Battery Capacity | 0 | 160 | Predefined Number | SMS Text | ||
52450 | Uint8 | 0 | 0 | 3 | 0 – None | Priority | Power System Error | Super Soco |
1 – Low | ||||||||
2 – High | ||||||||
3 – Panic | ||||||||
52454 | Uint8 | 0 | 0 | 2 | 0 – No | Event Only | ||
1 – Yes | ||||||||
2 – Crash | ||||||||
52451 | Uint8 | 3 | 0 | 6 | 0 – On Exit | Operand | ||
1 – On Entrance | ||||||||
2 – On Both | ||||||||
3 – Monitoring | ||||||||
4 – On Hysteresis | ||||||||
5 – On Change | ||||||||
6 – On Delta Change | ||||||||
7448 | Uint8 | 0 | 0 | 10 | Predefined Number | Send SMS To | ||
8448 | String | Power System Error Code | 0 | 160 | Predefined Number | SMS Text | ||
52460 | Uint8 | 0 | 0 | 3 | 0 – None | Priority | Power Train Error | Super Soco |
1 – Low | ||||||||
2 – High | ||||||||
3 – Panic | ||||||||
52464 | Uint8 | 0 | 0 | 2 | 0 – No | Event Only | ||
1 – Yes | ||||||||
2 – Crash | ||||||||
52461 | Uint8 | 3 | 0 | 6 | 0 – On Exit | Operand | ||
1 – On Entrance | ||||||||
2 – On Both | ||||||||
3 – Monitoring | ||||||||
4 – On Hysteresis | ||||||||
5 – On Change | ||||||||
6 – On Delta Change | ||||||||
7449 | Uint8 | 0 | 0 | 10 | Predefined Number | Send SMS To | ||
8449 | String | Power Train Error Code | 0 | 160 | Predefined Number | SMS Text | ||
52470 | Uint8 | 0 | 0 | 3 | 0 – None | Priority | Power System Error | Super Soco |
1 – Low | ||||||||
2 – High | ||||||||
3 – Panic | ||||||||
52474 | Uint8 | 0 | 0 | 2 | 0 – No | Event Only | ||
1 – Yes | ||||||||
2 – Crash | ||||||||
52471 | Uint8 | 3 | 0 | 6 | 0 – On Exit | Operand | ||
1 – On Entrance | ||||||||
2 – On Both | ||||||||
3 – Monitoring | ||||||||
4 – On Hysteresis | ||||||||
5 – On Change | ||||||||
6 – On Delta Change | ||||||||
7450 | Uint8 | 0 | 0 | 10 | Predefined Number | Send SMS To | ||
8450 | String | Instrument System Error Code | 0 | 160 | Predefined Number | SMS Text |