Product change notifications (PCN) is the way of informing customers of upcoming changes related to Teltonika products. This includes outward appearance adjustments, hardware improvements, firmware changes, changes to package contents, etc.
This page stores information regarding changes to the FMC640 tracking device. Below you will find a list of both upcoming and already implemented changes sorted from newest to oldest (top to bottom).
The product End of Life (EOL) announcement signifies that a product has entered the final phase of Teltonika Product Life Cycle. Announcement serves as an advance notice of product termination in accordance with Teltonika EOL policy. Nevertheless, there is still enough time for you to order and get support that you need for the products that will be discontinued. Please contact your sales manager for more information.
End Of Production date: 2023-09-28
Last Order date: 2023-12-28
End of Bug-fixing date: 2024-09-28
End of Support date: 2025-03-28
2023.07.18: Base firmware update
We would like to inform you about the base firmware update for FMC640 starting in start - August 2023. New production firmware version will be 01.02.27.Rev.06.
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period, clients might receive devices with the previous Firmware versions used in manufacture.
During transitional period, codes ordered with base Firmware version might contain 01.02.22.Rev.04 Firmware versions.
Suggested implementation plan
If you are using a special firmware version and would like an upgrade to new features of the latest base firmware, please contact your Teltonika sales manager
2023.07.10: GNSS antenna changes
We would like to inform you about the GNSS antenna changes update for FMC640 starting date changed to August 2023.
Change description
Change type
Mechanical part changes
Detailed description
Old version:
Dimensions - 45.2x35.8x15.1 mm
Center frequency - 1575.42 MHz, 1602 MHz
Bandwidth - 10 MHz
VSWR on bandwidth - <1.5
GAIN - 2 dB
LNA minimum gain - 26 dB
LNA maximum gain - 30 dB
Consumption - 11 mA
New version:
Dimensions - 46x44x13 mm
Center frequency - 1575.42 MHz, 1602 MHz
Bandwidth - 35 MHz
VSWR on bandwidth - <1.9
GAIN - 3 dB
LNA minimum gain - 26.5 dB
LNA maximum gain - 29.5 dB
Consumption - 9 mA Consumption - 11 mA
Change reasons
Reaction to antenna market volatility.
Product release date
August 2023
Affected products
Model
Affected order codes
Order code changes
FMC640
FMC640*******order codes
No changes
Change impact
Risk assessment
No risk factors encountered with this change. New antennas were used in mass production before
Suggested implementation plan
No implementation plan needed
2023.04.12: SIM usage recommendation update
We would like to inform you about the SIM usage recommendation change - due to SIM card market tendencies (Standard size SIM cards being made to split to 3 parts) FMC640 First Start
Recommendation description
Recommendation reason
Due to SIM card market tendencies (Standard size SIM cards being made to split to 3 parts)
Detailed description
New paragraph about SIM usage is added to product First Start description.
Previously SIM insertion recommendation was only described in schematics - SIM1 shown in lower slot, SIM2 in upper slot.
Due to SIM market tendencies the documentation was updated to more clearly state SIM1 and SIM2 usage recommendations:
FMX6 devices use Standard size SIM cards for SIM1 and SIM2. Currently most of the SIM cards provided by operators can be disassembled into 3 parts - Standard/Micro/Nano. Depending on the SIM card construction - during device usage in harsh conditions, SIM assembly might come apart which causes instability when connecting to operator.
To avoid such risk:
1) If possible - ask operator for Standard SIM card with solid construction (not pre-cut to 3 parts)
2) Do not use SIM cards that were previously disassembled (SIM was taken apart previously)
3) If you plan to use only one SIM card - insert it into SIM1 slot (lower slot) - this ensures greater pressure on SIM contacts as the contact bed is pushed by PCB.
When 2 SIM cards are used simultaneously risk is mitigated as well - when SIM1 is inserted, a greater pressure is applied for SIM2, so SIM parts are harder to come lose
Change impact
Risk assessment
Recommendation updated to mitigate risk.
Suggested implementation plan
If you used one SIM card and it's placed in SIM1 slot (lower) - no implementation plan needed.
If you used 2 SIM cards - SIM1 in lower slot, SIM2 in upper slot - no implementation plan needed.
If you used eSIM - no implementation plan needed.
If you used one SIM card and it is inserted into SIM2 slot (upper) - to mitigate risk of bad operator connectivity due to SIM construction - for future installations - when only 1 SIM card is used - insert it into SIM1 slot (lower)
Additionally: If possible - ask operator for Standard SIM card with solid construction (not pre-cut to 3 parts)
2023.03.01: GNSS antenna changes
We would like to inform you about the GNSS antenna changes update for FMC640 starting date changed to March 2023.
Change description
Change type
Mechanical part changes
Detailed description
Old version:
Dimensions - 46x44x13 mm
Center frequency - 1575.42 MHz, 1602 MHz
Bandwidth - 35 MHz
VSWR on bandwidth - <1.9
GAIN - 3 dB
LNA minimum gain - 26.5 dB
LNA maximum gain - 29.5 dB
Consumption - 9 mA
New version:
Dimensions - 45.2x35.8x15.1 mm
Center frequency - 1575.42 MHz, 1602 MHz
Bandwidth - 10 MHz
VSWR on bandwidth - <1.5
GAIN - 2 dB
LNA minimum gain - 26 dB
LNA maximum gain - 30 dB
Consumption - 11 mA
Change reasons
Reaction to antenna market volatility.
Product release date
March 2023
Affected products
Model
Affected order codes
Order code changes
FMC640
FMC640*******order codes
No changes
Change impact
Risk assessment
No risk factors encountered with this change. New antennas were used in mass production before
Suggested implementation plan
No implementation plan needed
2022.09.02: Base firmware update
We would like to inform you about the base firmware update for FMC640 starting in start - September 2022. New production firmware version will be 01.02.22.Rev.04.
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period, clients might receive devices with the previous Firmware versions used in manufacture.
During transitional period, codes ordered with base Firmware version might contain 01.00.13.Rev.00 and 01.02.22.Rev.02 Firmware versions.
Suggested implementation plan
If you are using a special firmware version and would like an upgrade to new features of the latest base firmware, please contact your Teltonika sales manager
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2022.05.24: GNSS antenna changes
We would like to inform you about the GNSS antenna changes for FMC640 starting September 2022.
Change description
Change type
Mechanical part changes
Detailed description
Old version:
Dimensions - 46x44x13 mm
Center frequency - 1575.42 MHz, 1602 MHz
Bandwidth - 35 MHz
VSWR on bandwidth - <1.9
GAIN - 3 dB
LNA minimum gain - 26.5 dB
LNA maximum gain - 29.5 dB
Consumption - 9 mA
New version:
Dimensions - 45.2x35.8x15.1 mm
Center frequency - 1575.42 MHz, 1602 MHz
Bandwidth - 10 MHz
VSWR on bandwidth - <1.5
GAIN - 2 dB
LNA minimum gain - 26 dB
LNA maximum gain - 30 dB
Consumption - 11 mA
Change reasons
Reaction to antenna market volatility.
Product release date
September 2022
Affected products
Model
Affected order codes
Order code changes
FMC640
FMC640*******order codes
No changes
Change impact
Risk assessment
No risk factors encountered with this change
Suggested implementation plan
No implementation plan needed
2022.05.16: 1-wire power voltage increase
We would like to inform you that FMC640 will have increased 1-wire power output in updated PCB versions.
Following the increasing demand to make "1-wire power" output 5V - starting from 2022 June - "1-wire power" output will be 5 V instead of 3.5 V.
Change description
Change type
Internal
Detailed description
Old version:
1-wire interface
Value
Power line output voltage
3.3-3.9 V
Power line output current, max
140 mA
New version:
1-wire interface
Value
Power line output voltage
4.5-5 V
Power line output current, max
250 mA
Change reasons/Description
Due customer demand in having 5V output on device and increased 1-wire solution stability (where power is required)
Product release date
June 2022.
Affected products
Model
Affected order codes
Order code changes
FMC640
FMC640*******
1-wire output voltage increase
Change impact
Risk assessment
During the transitional period, customers might receive devices with different 1-wire power output voltages.
Suggested implementation plan
No implementation plan needed
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2021.08.03: Upgraded casing
We would like to inform you, that FMC640 device case will be updated in the factory by the end of August 2021.
Change description
Change type
External/visual
Detailed description
Old version:
New version:
Change reasons/Description
Changes are made only in internal part of the case:. 1. Additional ribs added to battery guard walls 2. A third section of the wall added Changes are made to ensure easier and more sufficient manufacturing process of the case itself - change has no effect on device functioning.
Product release date
End of August 2021
Affected products
Model
Affected order codes
Order code changes
FMC640
FMC640*******
New casing
Change impact
Risk assessment
No risk factors encountered with this change
Suggested implementation plan
No implementation plan needed
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2021.08.16: SMA soldering changes
We would like to inform you that Antenna connectors (SMA SMD type) in FMC640 devices will be soldered from both sides of PCB starting in first half of September 2021.
Change description
Change type
Internal
Detailed description
Old version:
New version:
Change reasons/Description
In order to increase the structural rigidity and unify the manufacturing process of Teltonika IoT Group devices, SMA connector will be soldered on the top side of PCB (same as before) and on the bottom side of PCB (performed additionally).
Product release date
First half of September 2021.
Affected products
Model
Affected order codes
Order code changes
FMC640
FMC640*******
SMA soldering changes
Change impact
Risk assessment
Due to THT assembly process, some devices might have an excess amount of soldering on the SMA connector. This does not affect GSM/GNSS antenna characteristics and does not interfere with device case assembly, therefore, device functionality remains unchanged.
Suggested implementation plan
No implementation plan needed
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2021.08.03: Upgraded casing
We would like to inform you, that FMC640 device case will be updated in the factory by the end of August 2021.
Change description
Change type
External/visual
Detailed description
Old version:
New version:
Change reasons/Description
Changes are made only in internal part of the case:. 1. Additional ribs added to battery guard walls 2. A third section of the wall added Changes are made to ensure easier and more sufficient manufacturing process of the case itself - change has no effect on device functioning.
Product release date
End of August 2021
Affected products
Model
Affected order codes
Order code changes
FMC640
FMC640*******
New casing
Change impact
Risk assessment
No risk factors encountered with this change
Suggested implementation plan
No implementation plan needed
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2021.05.26: Base firmware update
We would like to inform you about the base firmware update for FMC640 starting from May 26 2021. New production firmware version will be 01.00.13.
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
Suggested implementation plan
If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2021.05.18: New material and design changes on the device casing
We would like to inform you, that FMC640 device case will be updated in the factory on first half of June 2021.
Change description
Change type
External/visual
Detailed description
Old version:
New version:
Change reasons/Description
1. New material unifies the device design across all platforms. 2. LED indentations improve Dust/Water resistance - LEDs are visible through thin layer of material. 3. New battery guard ensures battery placement during device transportation and usage.
Product release date
First half of June 2021
Affected products
Model
Affected order codes
Order code changes
FMC640
FMC640*******
New casing
Change impact
Risk assessment
No risk factors encountered with this change
Suggested implementation plan
Small indentation on top of USB socket will allow you to identify the cases quicker
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2020.11.24: GNSS antenna changes
We would like to inform you about the GNSS antenna changes for FMC640 starting from late December 2020 - early January 2021.
Change description
Change type
Mechanical part changes
Detailed description
Old version:
Dimensions - 45.2x35.8x15.1 mm
Center frequency - 1575.42 MHz, 1600 MHz
Bandwidth - 10 MHz
VSWR on bandwidth - <1.5
GAIN - 3 dB
LNA minimum gain - 26 dB
LNA maximum gain - 30 dB
Consumption - 11 mA
New version:
Dimensions - 46x44x13 mm
Center frequency - 1575.42 MHz, 1602 MHz Bandwidth - 35 MHz VSWR on bandwidth - <1.9
GAIN - 3 dB
LNA minimum gain - 26.5 dB
LNA maximum gain - 29.5 dB
Consumption - 9 mA
Change reasons
According to technical comparison new antenna is better by next parameters: center frequency, bandwidth, consumption. Other parameters are the same. Moreover, the new antenna is thinner, which gives the opportunity to mount it, where it was not possible before and makes installation easier.
Product release date
Late December 2020 - Early January 2021
Affected products
Model
Affected order codes
Order code changes
FMB640
FMC640*******order codes
No changes
Change impact
Risk assessment
No risk factors encountered with this change
Suggested implementation plan
No implementation plan needed
2020.10.26: Base firmware update
We would like to inform you about the base firmware update for FMC640 starting from October 26th, 2020. New production firmware version will be 01.00.05.
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically
Suggested implementation plan
If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above