Template:SAS device Parameter list - Communication modifications RS232
Revision as of 10:29, 22 September 2023 by Jonas.sterbavicius (talk | contribs)
RS232
Mode
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
150 | Uint16 | 0 | 0 | 1 | 0 – Disable | External UART Mode |
1 – RS232 |
RS232 Mode
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
151 | Uint16 | 0 | 0 | 10 | 0 – Log Mode | Eventual Records |
1 – NMEA | ||||||
7 – TCP Ascii | ||||||
8 – TCP Binary | ||||||
9 – TCP Ascii Buffered | ||||||
10 – TCP Binary Buffered |
RS232 Settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
153 | Uint16 | 1 | 0 | 1 | 0 – Default | Eventual Records (Parity) |
1 – None | ||||||
2 – Odd | ||||||
3 – Even | ||||||
152 | Uint16 | 1 | 0 | 1 | 0 – Default | Baudrate |
1 – 1200 | ||||||
2 – 2400 | ||||||
3 – 9600 | ||||||
4 – 14400 | ||||||
5 – 19200 | ||||||
6 – 38400 | ||||||
7 – 57600 | ||||||
8 – 115200 | ||||||
158 | Uint16 | 0 | 0 | 1 | 0 – Disable | Message Timestamp |
1 – Enable |
TCP Binary Mode Settings
Parameter ID | Parameter Type | Default value | Value range | Value | Parameter name | |
---|---|---|---|---|---|---|
Min | Max | |||||
154 | Uint8 | 0 | 0 | 255 | - | Prefix 1 |
155 | Uint8 | 0 | 0 | 255 | - | Prefix 2 |
156 | Uint8 | 0 | 0 | 255 | - | Prefix 3 |