Test parameters

Revision as of 15:07, 28 November 2023 by Gediminas.suminas (talk | contribs) (Created page with "__TOC__ ===System Parameter List=== ====System Settings==== ---- {| class="nd-othertables_2" style="width:100%;" |+ ! rowspan="2" style="width:10%; vertical-align: middle;...")

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)

System Parameter List

System Settings


Parameter ID Property Name Value range Description Values
Min Max
138 Movement Source 1 15 The selection of movement detection source/sources, which determines how the device will switch between "On stop" and "Moving' working modes in "Data Acquisition" settings

1 – Ignition
2 – Accelerometer
4 – GNSS
8 – CAN Speed

133 Speed Source 0 1 Parameter, which determines which speed source to use

0 – GNSS
1 – OBD/CAN


Static Navigation Settings


Parameter ID Property Name Value range Description Values
Min Max
106 Static Navigation 0 1 Static Navigation is a filter, which filters out location jumps when the vehicle is stationary

0 – Disable
1 – Enable

112 Static Navition Source 0 3 Static nativation exit (movement) detection source

0 – Movement Source
2 – Ignition Source
3 – Movement and Ignition Source