FMB150 Teltonika Data Sending Parameters ID
Document updated according to firmware FMB.Ver.03.28.07.Rev.152 and newer.
FMB AVL ID's consist of these parameters groups:
Permanent I/O elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
239 | Ignition | 1 | Unsigned | 0 | 1 | - | - |
0 – Ignition Off |
Permanent I/O Elements | |
240 | Movement | 1 | Unsigned | 0 | 1 | - | - |
0 – Movement Off |
Permanent I/O elements | |
80 | Data Mode | 1 | Unsigned | 0 | 5 | - | - |
0 – Home On Stop |
Permanent I/O Elements | |
21 | GSM Signal | 1 | Unsigned | 0 | 5 | - | - |
Value in range 1-5 |
Permanent I/O Elements | |
200 | Sleep Mode | 1 | Unsigned | 0 | 4 | - | - |
0 - No Sleep |
Permanent I/O Elements | |
69 | GNSS Status | 1 | Unsigned | 0 | 3 | - | - |
0 - GNSS OFF |
Permanent I/O Elements | |
181 | GNSS PDOP | 2 | Unsigned | 0 | 500 | 0.1 | Coefficient, calculation formula | Permanent I/O Elements | ||
182 | GNSS HDOP | 2 | Unsigned | 0 | 500 | 0.1 | Coefficient, calculation formula | Permanent I/O Elements | ||
66 | External Voltage | 2 | Unsigned | 0 | 65535 | 0.001 | V |
Voltage |
Permanent I/O elements | |
24 | Speed | 2 | Unsigned | 0 | 350 | - | km/h |
GNSS Speed |
Permanent I/O elements | |
205 | GSM Cell ID | 2 | Unsigned | 0 | 65535 | - | - |
GSM base station ID |
Permanent I/O elements | |
206 | GSM Area Code | 2 | Unsigned | 0 | 65535 | - | - |
Location Area code (LAC), it depends on GSM operator. It provides unique number which assigned to a set of base GSM stations. |
Permanent I/O elements | |
67 | Battery Voltage | 2 | Unsigned | 0 | 65535 | 0.001 | V |
Voltage |
Permanent I/O elements | |
68 | Battery Current | 2 | Unsigned | 0 | 65535 | 0.001 | A |
Current |
Permanent I/O elements | |
241 | Active GSM Operator | 4 | Unsigned | 0 | 4294967295 | - | - |
Currently used GSM Operator code |
Permanent I/O elements | |
199 | Trip Odometer | 4 | Unsigned | 0 | 2147483647 | - | m |
Trip Odometer value |
Permanent I/O elements | |
16 | Total Odometer | 4 | Unsigned | 0 | 2147483647 | - | - |
Total Odometer value in meters |
Permanent I/O elements | |
1 | Digital Input 1 | 1 | Unsigned | 0 | 1 | - | - |
Logic: 0/1 |
Permanent I/O elements | |
9 | Analog Input 1 | 2 | Unsigned | 0 | 65535 | 0.001 | mV |
Voltage |
Permanent I/O elements | |
179 | Digital Output 1 | 1 | Unsigned | 0 | 1 | - | - |
Logic: 0/1 |
Permanent I/O elements | |
12 | Fuel Used GPS | 4 | Unsigned | 0 | 4294967295 | 0.001 | l |
Fuel Used |
Permanent I/O elements | |
13 | Fuel Rate GPS | 2 | Unsigned | 0 | 32767 | 0.01 | l/100km |
Average Fuel Use |
Permanent I/O elements | |
17 | Axis X | 2 | Signed | -8000 | 8000 | - | mG |
X axis value |
Permanent I/O elements | |
18 | Axis Y | 2 | Signed | -8000 | 8000 | - | mG |
Y axis value |
Permanent I/O elements | |
19 | Axis Z | 2 | Signed | -8000 | 8000 | - | mG |
Z axis value |
Permanent I/O elements | |
11 | ICCID1 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - |
Value of SIM ICCID, MSB |
Permanent I/O elements | |
10 | SD Status | 1 | Unsigned | 0 | 1 | - | - |
0 - not present 1 - present |
Permanent I/O elements | |
2 | Digital Input 2 | 1 | Unsigned | 0 | 1 | - | - |
Logic: 0/1 |
Permanent I/O elements | |
3 | Digital Input 3 | 1 | Unsigned | 0 | 1 | - | - |
Logic: 0/1 |
Permanent I/O elements | |
6 | Analog Input 2 | 2 | Unsigned | 0 | 65535 | 0.001 | mV |
Voltage |
Permanent I/O elements | |
180 | Digital Output 2 | 1 | Unsigned | 0 | 1 | - | - | Logic 0/1 | Permanent I/O elements | |
72 | Dallas Temperature 1 | 4 | Signed | -550 | 1150 | 0.1 | °C | Degrees ( °C ), -55 - +115,
if 850 – Sensor not ready |
Permanent I/O elements | |
73 | Dallas Temperature 2 | 4 | Signed | -550 | 1150 | 0.1 | °C | Degrees ( °C ), -55 - +115,
if 850 – Sensor not ready |
Permanent I/O elements | |
74 | Dallas Temperature 3 | 4 | Signed | -550 | 1150 | 0.1 | °C | Degrees ( °C ), -55 - +115,
if 850 – Sensor not ready |
Permanent I/O elements | |
75 | Dallas Temperature 4 | 4 | Signed | -550 | 1150 | 0.1 | °C | Degrees ( °C ), -55 - +115,
if 850 – Sensor not ready |
Permanent I/O elements | |
76 | Dallas Temperature ID 1 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Dallas sensor ID | Permanent I/O elements | |
77 | Dallas Temperature ID 2 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Dallas sensor ID | Permanent I/O elements | |
79 | Dallas Temperature ID 3 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Dallas sensor ID | Permanent I/O elements | |
71 | Dallas Temperature ID 4 | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | Dallas sensor ID | Permanent I/O elements | |
78 | iButton | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | iButton ID | Permanent I/O elements | |
207 | RFID | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | RFID ID | Permanent I/O elements | |
201 | LLS 1 Fuel Level | 2 | Signed | -4 | 32767 | - | kvants or ltr | Fuel level measured by LLS sensor via RS232/RS485 | Permanent I/O elements | |
202 | LLS 1 Temperature | 1 | Signed | -128 | 127 | - | °C | Fuel temperature measured by LLS via RS232/RS485 | Permanent I/O elements | |
203 | LLS 2 Fuel Level | 2 | Signed | -4 | 32767 | - | kvants or ltr | Fuel level measured by LLS sensor via RS485 | Permanent I/O elements | |
204 | LLS 2 Temperature | 1 | Signed | -128 | 127 | - | °C | Fuel temperature measured by LLS via RS485 | Permanent I/O elements | |
210 | LLS 3 Fuel Level | 2 | Unsigned | -4 | 32767 | - | kvants or ltr | Fuel level measured by LLS sensor via RS485 | Permanent I/O elements | |
211 | LLS 3 Temperature | 1 | Signed | -128 | 127 | - | °C | Fuel temperature measured by LLS via RS485 | Permanent I/O elements | |
212 | LLS 4 Fuel Level | 2 | Signed | -4 | 32767 | - | kvants or ltr | Fuel level measured by LLS sensor via RS485 | Permanent I/O elements | |
213 | LLS 4 Temperature | 1 | Signed | -128 | 127 | - | °C | Fuel temperature measured by LLS via RS485 | Permanent I/O elements | |
214 | LLS 5 Fuel Level | 2 | Signed | -4 | 32767 | - | kvants or ltr | Fuel level measured by LLS sensor via RS485 | Permanent I/O elements | |
215 | LLS 5 Temperature | 1 | Signed | -128 | 127 | - | °C | Fuel temperature measured by LLS via RS485 | Permanent I/O elements | |
15 | Eco Score | 2 | Unsigned | 0 | 65535 | 0.01 | - | Average amount of events on some distance | Permanent I/O elements | |
113 | Battery Level | 1 | Unsigned | 0 | 100 | - | % | Battery capacity level | Permanent I/O elements | |
238 | User ID | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | MAC address of NMEA receiver device connected via Bluetooth®| style="vertical-align: middle; text-align: center;" | | Permanent I/O elements | |
237 | Network Type | 1 | Unsigned | 0 | 1 | - | - | 0 - 3G
1 - GSM |
FM3001 |
Permanent I/O elements |
8 | Authorized iButton | 8 | Unsigned | 0 | 0xffffffffffffffff | - | - | If ID is shown in this I/O that means that attached iButton is in iButton List | Permanent I/O elements | |
4 | Pulse Counter Din1 | 4 | Unsigned | 0 | 4294967295 | - | - | Counts pulses, count is reset when records are saved | Permanent I/O elements | |
5 | Pulse Counter Din2 | 4 | Unsigned | 0 | 4294967295 | - | - | Counts pulses, count is reset when records are saved | Permanent I/O elements | |
263 | BT Status | 1 | Unsigned | 0 | 4 | - | - | 0 - BT is disabled
1 - BT Enabled, not device connected 2 - Device connected, BTv3 Only 3 - Device connected, BLE only 4 - Device connected, BLE + BT |
Permanent I/O elements | |
264 | Barcode ID | Variable | ASCII | 0 | 32 | - | - | Barcode ID | Permanent I/O elements | |
269 | Escort LLS Temperature #1 | 2 | Signed | -128 | 127 | - | °C | Fuel temperature | Permanent I/O elements | |
270 | Escort LLS Fuel level #1 | 2 | Unsigned | 0 | 65535 | - | - | Fuel Level | Permanent I/O elements | |
271 | Escort LLS Battery Voltage #1 | 2 | Unsigned | 0 | 65535 | 0.01 | V | Battery Voltage | Permanent I/O elements | |
272 | Escort LLS Temperature #2 | 2 | Signed | -128 | 127 | - | °C | Fuel temperature | Permanent I/O elements | |
273 | Escort LLS Fuel level #2 | 2 | Unsigned | 0 | 65535 | - | - | Fuel Level | Permanent I/O elements | |
274 | Escort LLS Battery Voltage #2 | 2 | Unsigned | 0 | 65535 | 0.01 | V | Battery Voltage | Permanent I/O elements | |
275 | Escort LLS Temperature #3 | 2 | Signed | -128 | 127 | - | °C | Fuel temperature | Permanent I/O elements | |
276 | Escort LLS Fuel level #3 | 2 | Unsigned | 0 | 65535 | - | - | Fuel Level | Permanent I/O elements | |
277 | Escort LLS Battery Voltage #3 | 2 | Unsigned | 0 | 65535 | 0.01 | V | Battery Voltage | Permanent I/O elements | |
278 | Escort LLS Temperature #4 | 2 | Signed | -128 | 127 | - | °C | Fuel temperature | Permanent I/O elements | |
279 | Escort LLS Fuel level #4 | 2 | Unsigned | 0 | 65535 | - | - | Fuel Level | Permanent I/O elements | |
280 | Escort LLS Battery Voltage #4 | 2 | Unsigned | 0 | 65535 | 0.01 | V | Battery Voltage | Permanent I/O elements | |
303 | Instant Movement | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 returns movement value | Permanent I/O elements | |
327 | UL202-02 Sensor Fuel level | 2 | Signed | -150 | 32767 | 0.1 | mm | UL202-02 Sensor Fuel level | Permanent I/O elements | |
483 | UL202-02 Sensor Status | 1 | Unsigned | 0 | 255 | - | - | UL202-02 sensor status codes | Permanent I/O elements | |
380 | Digital output 3 | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 | Permanent I/O elements | |
381 | Ground Sense | 1 | Unsigned | 0 | 1 | - | - | Logic: 0/1 | FMB130 |
Permanent I/O elements |
387 | ISO6709 Coordinates | 34 | HEX | 0 | 0x7fffffffffffffff | - | - | ISO6709 Coordinates
Latitude, Longitude (in Degrees, Minutes and Seconds) and Altitude: IO value format: ±DDMMSS.SSSS±DDDMMSS.SSSS±AAA.AAA/ |
Permanent I/O elements | |
636 | UMTS/LTE Cell ID | 4 | Unsigned | 0 | 0xFFFFFFFF | - | - | Permanent I/O elements | ||
403 | Driver Name | 35 | Unsigned | - | - | - | - | Driver name extracted from card, displayed without delimiters ($ signs) |
FMBXXX FMU126 |
Permanent I/O elements |
404 | Driver card license type | 1 | Unsigned | 0 | 8 | - | - |
None - 0 |
FMBXXX FMU126 |
Permanent I/O elements |
405 | Driver Gender | 1 | Unsigned | 0 | 2 | - | - |
None - 0 |
FMBXXX FMU126 |
Permanent I/O elements |
406 | Driver Card ID | 4 | Unsigned | 0 | 4294967295 | - | - |
None - 0 |
FMBXXX FMU126 |
Permanent I/O elements |
407 | Driver card expiration date | 1 | Unsigned | 0 | 9999 | - | - |
FMBXXX FMU126 |
Permanent I/O elements | |
408 | Driver Card place of issue | 4 | Unsigned | 0 | 65535 | - | - | Extracted from card |
FMBXXX FMU126 |
Permanent I/O Elements |
409 | Driver Status Event | 1 | Unsigned | 0 | 2 | - | - |
Registered - 0 |
FMBXXX FMU126 |
Permanent I/O elements |
329 | AIN Speed | 2 | Unsigned | 0 | 65535 | - | - | MSP500 | Permanent I/O elements | |
500 | MSP500 vendor name | 40 | ASCII | 0 | 40 | - | - | Name of the integrator who installed the device | MSP500 | Permanent I/O elements |
501 | MSP500 vehicle number | 40 | ASCII | 0 | 40 | - | - | Vehicle number on which the device is installed | MSP500 | Permanent I/O elements |
502 | MSP500 speed sensor | 1 | unsigned | 0 | 1 | - | - | Status of the speed sensor | MSP500 | Permanent I/O elements |
637 | Wake Reason | 1 | Unsigned | 0 | 1 | - | - |
True if device was woken by RTC alarm |
Permanent I/O elements |
Eventual I/O elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
155 | Geofence zone 01 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
156 | Geofence zone 02 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
157 | Geofence zone 03 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
158 | Geofence zone 04 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
159 | Geofence zone 05 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
61 | Geofence zone 06 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
62 | Geofence zone 07 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
63 | Geofence zone 08 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
64 | Geofence zone 09 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
65 | Geofence zone 10 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
70 | Geofence zone 11 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
88 | Geofence zone 12 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
91 | Geofence zone 13 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
92 | Geofence zone 14 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
93 | Geofence zone 15 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
94 | Geofence zone 16 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
95 | Geofence zone 17 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
96 | Geofence zone 18 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
97 | Geofence zone 19 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
98 | Geofence zone 20 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
99 | Geofence zone 21 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
153 | Geofence zone 22 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
154 | Geofence zone 23 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
190 | Geofence zone 24 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
191 | Geofence zone 25 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
192 | Geofence zone 26 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
193 | Geofence zone 27 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
194 | Geofence zone 28 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
195 | Geofence zone 29 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
196 | Geofence zone 30 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
197 | Geofence zone 31 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
198 | Geofence zone 32 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
208 | Geofence zone 33 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
209 | Geofence zone 34 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
216 | Geofence zone 35 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
217 | Geofence zone 36 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
218 | Geofence zone 37 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
219 | Geofence zone 38 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
220 | Geofence zone 39 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
221 | Geofence zone 40 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
222 | Geofence zone 41 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
223 | Geofence zone 42 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
224 | Geofence zone 43 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
225 | Geofence zone 44 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
226 | Geofence zone 45 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
227 | Geofence zone 46 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
228 | Geofence zone 47 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
229 | Geofence zone 48 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
230 | Geofence zone 49 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
231 | Geofence zone 50 | 1 | Unsigned | 0 | 3 | - | - |
0 – target left zone |
Eventual I/O elements | |
175 | Auto Geofence | 1 | Unsigned | 0 | 1 | - | - |
0 – target left zone |
Eventual I/O elements | |
250 | Trip | 1 | Unsigned | 0 | 1 | - | - |
0 – trip stop |
Eventual I/O elements | |
255 | Over Speeding | 1 | Unsigned | 0 | 255 | - | km/h |
At over speeding start km/h, at over speeding end km/h |
Eventual I/O elements | |
257 | Crash trace data | Variable | HEX | 0 | 1200 | - | - | Crash trace data | Eventual I/O elements | |
285 | Blood alcohol content | 2 | Unsigned | 0 | 9999 | - | - | Alcohol content in blood in perlims and mode. First 14 bits from MSB are perlims multiplied by 1000 and last to bits are 0 - Passive test, 1 Active test, 2 and 3 are reserved. | FMB125 | Eventual I/O elements |
251 | Idling | 1 | Unsigned | 0 | 1 | - | - |
0 – moving |
Eventual I/O elements | |
253 | Green driving type | 1 | Unsigned | 1 | 3 | - | - |
1 – harsh acceleration |
Eventual I/O elements | |
246 | Towing | 1 | Unsigned | 0 | 1 | - | - |
0 – steady |
Eventual I/O elements | |
252 | Unplug | 1 | Unsigned | 0 | 1 | - | - |
0 – battery present |
Eventual I/O elements | |
247 | Crash detection | 1 | Unsigned | 1 | 6 | - | - |
1 – real crash detected (device is calibrated) |
Eventual I/O elements | |
248 | Immobilizer | 1 | Unsigned | 0 | 2 | - | - |
0 – iButton not connected |
Eventual I/O elements | |
254 | Green Driving Value | 1 | Unsigned | 0 | 255 | acc and braking: 0.01 | G or rad | Depending on green driving type: if harsh acceleration or braking – g*100 (value 123 -> 1.23g). If Green driving source is „GPS“ – harsh cornering value is rad/s*100. If source is „Accelerometer“ – g*100. | Eventual I/O elements | |
249 | Jamming | 1 | Unsigned | 0 | 1 | - | - |
0 – jamming stop |
Eventual I/O elements | |
14 | ICCID2 | 8 | Unsigned | 0 | 0xFFFFFFFFFFFFFFFF | - | - |
Value of SIM ICCID, LSB |
Eventual I/O elements | |
243 | Green driving event duration | 2 | Unsigned | 0 | 65535 | - | ms |
Duration of event that did generate Green driving |
Eventual I/O elements | |
236 | Alarm | 1 | Unsigned | 0 | 1 | - | - |
0 – Reserved |
Eventual I/O elements | |
258 | EcoMaximum | 8 | Unsigned | 0 | 0xFFFFFFFFFFFFFFFF | - | - |
Element stores maximum accelerometer values in mg on all axis during Eco driving event |
Eventual I/O elements | |
259 | EcoAverage | 8 | Unsigned | 0 | 0xFFFFFFFFFFFFFFFF | - | - |
Element stores average accelerometer values in mg on all axis during Eco driving event |
Eventual I/O elements | |
260 | EcoDuration | 2 | Unsigned | 0 | 65535 | - | ms |
Duration of Eco driving event in miliseconds |
Eventual I/O elements | |
283 | Driving State | 1 | Unsigned | 0 | 3 | - | - |
1 - Ignition ON |
Eventual I/O elements | |
284 | Driving Records | 2 | Unsigned | 0 | 65535 | - | - |
Number of Records between Ignition ON and Ignition OFF |
Eventual I/O elements | |
391 | Private mode | 1 | Unsigned | 0 | 255 | - | - | Private mode state
0 - Private mode off 1 - Private mode on |
Eventual I/O elements | |
317 | Crash event counter | 1 | Unsigned | 0 | 255 | - | - | Connects trace with specific eventual crash record | Eventual I/O elements | |
449 | Ignition On Counter | 4 | Unsigned | 0 | 2147483647 | - | s |
0 - Disable |
Eventual I/O elements |
OBD elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
256 | VIN | 17 | ASCII | 0 | 0xff | - | - | VIN number | OBD elements | |
30 | Number of DTC | 1 | ASCII | 0 | 255 | - | - | Number of DTC | OBD elements | |
31 | Engine Load | 1 | Unsigned | 0 | 100 | - | % | Calculated engine load value | OBD elements | |
32 | Coolant Temperature | 1 | Signed | -128 | 127 | - | °C |
Engine coolant temperature |
OBD elements | |
33 | Short Fuel Trim | 1 | Signed | -100 | 99 | - | % |
Short term fuel trim 1 |
OBD elements | |
34 | Fuel pressure | 2 | Unsigned | 0 | 765 | - | kPa |
Fuel pressure |
OBD elements | |
35 | Intake MAP | 1 | Unsigned | 0 | 255 | - | kPa |
Intake manifold absolute pressure |
OBD elements | |
36 | Engine RPM | 2 | Unsigned | 0 | 16384 | - | rpm |
Engine RPM |
OBD elements | |
37 | Vehicle Speed | 1 | Unsigned | 0 | 255 | - | km/h |
Vehicle speed |
OBD elements | |
38 | Timing Advance | 1 | Signed | -64 | 64 | - | ° |
Timing advance |
OBD elements | |
39 | Intake Air Temperature | 1 | Signed | -128 | 127 | - | °C |
Intake air temperature |
OBD elements | |
40 | MAF | 2 | Unsigned | 0 | 65535 | 0.01 | g/sec |
MAF air flow rate |
OBD elements | |
41 | Throttle Position | 1 | Unsigned | 0 | 100 | - | % |
Throttle position |
OBD elements | |
42 | Runtime since engine start | 2 | Unsigned | 0 | 65535 | - | s |
Runtime since engine start |
OBD elements | |
43 | Distance Traveled MIL On | 2 | Unsigned | 0 | 65535 | - | km |
Distance ormattin MIL on |
OBD elements | |
44 | Relative Fuel Rail Pressure | 2 | Unsigned | 0 | 5178 | 0.1 | kPa |
Relative fuel rail pressure |
OBD elements | |
45 | Direct Fuel Rail Pressure | 2 | Unsigned | 0 | 65535 | 10 | kPa |
Direct Fuel Rail Pressure |
OBD elements | |
46 | Commanded EGR | 1 | Unsigned | 0 | 100 | - | % |
Commanded EGR |
OBD elements | |
47 | EGR Error | 1 | Signed | -100 | 100 | - | % |
EGR error |
OBD elements | |
48 | Fuel Level | 1 | Unsigned | 0 | 100 | - | % |
Fuel level |
OBD elements | |
49 | Distance Since Codes Clear | 2 | Unsigned | 0 | 65535 | - | km |
Distance traveled since codes cleared |
OBD elements | |
50 | Barometic Pressure | 1 | Unsigned | 0 | 255 | - | kPa |
Barometic pressure |
OBD elements | |
51 | Control Module Voltage | 2 | Unsigned | 0 | 65535 | 0.001 | V |
Control module voltage |
OBD elements | |
52 | Absolute Load Value | 2 | Unsigned | 0 | 25700 | - | % |
Absolute load value |
OBD elements | |
759 | Fuel Type | 1 | Unsigned | 0 | 255 | - | - |
0 Not available |
OBD elements | |
53 | Ambient Air Temperature | 1 | Signed | -128 | 127 | - | °C |
Ambient air temperature |
OBD elements | |
54 | Time Run With MIL On | 2 | Unsigned | 0 | 65535 | - | min |
Time run with MIL on |
OBD elements | |
55 | Time Since Codes Cleared | 2 | Unsigned | 0 | 65535 | - | min |
Time since codes cleared |
OBD elements | |
56 | Absolute Fuel Rail Pressure | 2 | Unsigned | 0 | 65535 | 0.1 | kPa |
Absolute fuel rail pressure |
OBD elements | |
57 | Hybrid battery pack life | 1 | Unsigned | 0 | 100 | - | % |
Hybrid battery pack remaining life |
OBD elements | |
58 | Engine Oil Temperature | 1 | Unsigned | 0 | 215 | - | °C |
Engine oil temperature |
OBD elements | |
59 | Fuel injection timing | 2 | Signed | -21000 | 30200 | 0.01 | ° |
Fuel injection timing |
OBD elements | |
543 | Hybrid System Voltage | 2 | Unsigned | 0 | 1024 | - | V |
Hybrid vehicle system voltage |
OBD elements | |
544 | Hybrid System Current | 2 | Signed | -3277 | 3277 | - | A |
Hybrid vehicle system current |
OBD elements | |
281 | Fault Codes | variable | ASCII | 0 | 128 | - | - |
Fault Codes (values separated via ",") |
OBD elements | |
60 | Fuel Rate | 2 | Unsigned | 0 | 32767 | 0.01 | L/h |
Engine fuel rate, L/h*100 |
OBD elements |
OBD OEM elements
Property ID in AVL packet | Property Name | Bytes | Type | Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
389 | OBD OEM Total Mileage | 4 | Unsigned | 0 | 0xffffffff | - | km | Total mileage received by requesting vehicle specific PID | FMB003 | OBD OEM elements |
390 | OBD OEM Fuel Level | 4 | Unsigned | 0 | 0xffffffff | 0.1 | l | Fuel level in litres received by requesting vehicle specific PID | FMB003 | OBD OEM elements |
410 | OEM Battery charge state | 1 | Unsigned | 0 | 1 | - | - |
0 – Not charging |
FMB001 FMC001 FMM001 FMB003 FMC003 FMM003 | OBD OEM elements |
411 | OEM Battery charge level | 1 | Unsigned | 0 | 100 | - | % | Represents battery charged level | FMB001 FMC001 FMM001 FMB003 FMC003 FMM003 | OBD OEM elements |
412 | OEM Battery power consumption | 2 | Unsigned | 0 | 65535 | - | kWh/100km | Represents battery power consumption | FMB001 FMC001 FMM001 FMB003 FMC003 FMM003 | OBD OEM elements |
755 | OEM Remaining distance | 2 | Unsigned | 0 | 65535 | - | km | Remaining distance until fuel tank empty or battery (EV) depleted | FMB001 FMC001 FMM001 FMB003 FMC003 FMM003 | OBD OEM elements |
BLE Sensors I/O elements
Property ID in AVL packet | Property Name | Bytes | T
ype |
Value range | Multiplier | Units | Description | HW Support | Parameter Group | |
---|---|---|---|---|---|---|---|---|---|---|
Min | Max | |||||||||
385 | Beacon | Variable | HEX | 0 | 1024 | - | - | List of Beacon IDs | Permanent I/O elements | |
25 | BLE Temperature #1 | 2 | Signed | -4000 | 12500 | 0.01* | °C |
Degrees ( °C ), -40 - +125; |
Bluetooth® Low Energy | |
26 | BLE Temperature #2 | 2 | Signed | -4000 | 12500 | 0.01* | °C |
Degrees ( °C ), -40 - +125; |
Bluetooth® Low Energy | |
27 | BLE Temperature #3 | 2 | Signed | -4000 | 12500 | 0.01* | °C |
Degrees ( °C ), -40 - +125; |
Bluetooth® Low Energy | |
28 | BLE Temperature #4 | 2 | Signed | -4000 | 12500 | 0.01* | °C |
Degrees ( °C ), -40 - +125; |
Bluetooth® Low Energy | |
29 | BLE Battery #1 | 1 | Unsigned | 0 | 100 | - | % | Battery level of sensor #1 | Bluetooth® Low Energy | |
20 | BLE Battery #2 | 1 | Unsigned | 0 | 100 | - | % | Battery level of sensor #2 | Bluetooth® Low Energy | |
22 | BLE Battery #3 | 1 | Unsigned | 0 | 100 | - | % | Battery level of sensor #3 | Bluetooth® Low Energy | |
23 | BLE Battery #4 | 1 | Unsigned | 0 | 100 | - | % | Battery level of sensor #4 | Bluetooth® Low Energy | |
86 | BLE Humidity #1 | 2 | Unsigned | 0 | 1000 | 0.1* | %RH | Humidity | Bluetooth® Low Energy | |
104 | BLE Humidity #2 | 2 | Unsigned | 0 | 1000 | 0.1* | %RH | Humidity | Bluetooth® Low Energy | |
106 | BLE Humidity #3 | 2 | Unsigned | 0 | 1000 | 0.1* | %RH | Humidity | Bluetooth® Low Energy | |
108 | BLE Humidity #4 | 2 | Unsigned | 0 | 1000 | 0.1* | %RH | Humidity | Bluetooth® Low Energy | |
270 | BLE Fuel Level #1 | 2 | Unsigned | 0 | 65535 | - | - | Fuel Level | Bluetooth® Low Energy | |
273 | BLE Fuel Level #2 | 2 | Unsigned | 0 | 65535 | - | - | Fuel Level | Bluetooth® Low Energy | |
276 | BLE Fuel Level #3 | 2 | Unsigned | 0 | 65535 | - | - | Fuel Level | Bluetooth® Low Energy | |
279 | BLE Fuel Level #4 | 2 | Unsigned | 0 | 65535 | - | - | Fuel Level | Bluetooth® Low Energy | |
306 | BLE Fuel Frequency #1 | 4 | Unsigned | 0 | 2147483647 | - | - | Frequency value of BLE fuel sensor #1 | Bluetooth® Low Energy | |
307 | BLE Fuel Frequency #2 | 4 | Unsigned | 0 | 2147483647 | - | - | Frequency value of BLE fuel sensor #2 | Bluetooth® Low Energy | |
308 | BLE Fuel Frequency #3 | 4 | Unsigned | 0 | 2147483647 | - | - | Frequency value of BLE fuel sensor #3 | Bluetooth® Low Energy | |
309 | BLE Fuel Frequency #4 | 4 | Unsigned | 0 | 2147483647 | - | - | Frequency value of BLE fuel sensor #4 | Bluetooth® Low Energy | |
335 | BLE Luminosity #1 | 2 | Unsigned | 0 | 0xFFFF | - | lx | Luminosity value of BLE sensor | Bluetooth® Low Energy | |
336 | BLE Luminosity #2 | 2 | Unsigned | 0 | 0xFFFF | - | lx | Luminosity value of BLE sensor | Bluetooth® Low Energy | |
337 | BLE Luminosity #3 | 2 | Unsigned | 0 | 0xFFFF | - | lx | Luminosity value of BLE sensor | Bluetooth® Low Energy | |
338 | BLE Luminosity #4 | 2 | Unsigned | 0 | 0xFFFF | - | lx | Luminosity value of BLE sensor | Bluetooth® Low Energy | |
331 | BLE 1 Custom #1 | Variable | HEX | 0 | - | - | - | Custom IO element for BLE sensor | Bluetooth® Low Energy | |
463 | BLE 1 Custom #2 | 8 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth® Low Energy | |
464 | BLE 1 Custom #3 | 8 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth® Low Energy | |
465 | BLE 1 Custom #4 | 8 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth® Low Energy | |
466 | BLE 1 Custom #5 | 8 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth® Low Energy | |
332 | BLE 2 Custom #1 | Variable | HEX | 0 | - | - | - | Custom IO element for BLE sensor | Bluetooth® Low Energy | |
467 | BLE 2 Custom #2 | 8 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth® Low Energy | |
468 | BLE 2 Custom #3 | 8 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth® Low Energy | |
469 | BLE 2 Custom #4 | 8 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth® Low Energy | |
470 | BLE 2 Custom #5 | 8 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth® Low Energy | |
333 | BLE 3 Custom #1 | Variable | HEX | 0 | - | - | - | Custom IO element for BLE sensor | Bluetooth® Low Energy | |
471 | BLE 3 Custom #2 | 8 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth® Low Energy | |
472 | BLE 3 Custom #3 | 8 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth® Low Energy | |
473 | BLE 3 Custom #4 | 8 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth® Low Energy | |
474 | BLE 3 Custom #5 | 8 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth® Low Energy | |
334 | BLE 4 Custom #1 | Variable | HEX | 0 | - | - | - | Custom IO element for BLE sensor | Bluetooth® Low Energy | |
475 | BLE 4 Custom #2 | 8 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth® Low Energy | |
476 | BLE 4 Custom #3 | 8 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth® Low Energy | |
477 | BLE 4 Custom #4 | 8 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth® Low Energy | |
478 | BLE 4 Custom #5 | 8 | UNSIGNED LONG INT | 0 | 4294967295 | - | - | Custom IO element for BLE sensor | Bluetooth® Low Energy |
81 Vehicle Speed 1 Unsigned 0 255 - km/h Value in km/h
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 82 Accelerator Pedal Position 1 Unsigned 0 102 - % Value in persentages, %
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 83 Fuel Consumed 4 Unsigned 0 2147483647 0.1 l Value in liters, L
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 84 Fuel Level 2 Unsigned 0 65535 0.1 l Value in liters, L
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 85 Engine RPM 2 Unsigned 0 16384 - rpm Value in rounds per minute, rpm
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 87 Total Mileage 4 Unsigned 0 4294967295 - m Value in meters, m
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 89 Fuel Level 1 Unsigned 0 6553 - % Value in percentages, %
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 90 Door Status 2 Unsigned 0 32512 - - Door status value: Min – 0, Max – 16128
Door status is represented as bitmask converted to decimal value. Possible values: 0 – all doors closed, 0x100 (256) – front left door is opened, 0x200 (512) – front right door is opened, 0x400 (1024) – rear left door is opened, 0x800 (2048) – rear right door is opened, 0x1000 (4096) – hood is opened, 0x2000 (8192) – trunk is opened, 0x4000 (16384) – roof is opened, 0x7F00 (32512) – all doors are opened,or combinations of values
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 103 Engine Worktime (counted) 4 Unsigned 0 16777215 - min Total Engine work time in minutes
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 105 Total Mileage (counted) 4 Unsigned 0 4294967295 - m Total Vehicle Mileage, m
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 107 Fuel Consumed (counted) 4 Unsigned 0 2147483647 0.1 l Total Fuel Consumed, l
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 111 AdBlue Level 1 Unsigned 0 6553 - % AdBlue, %
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 114 Engine Load 1 Unsigned 0 130 - % Engine load, %
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 115 Engine Temperature 2 Signed -600 1270 0.1 °C Engine Temperature, °C
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 118 Axle 1 Load 2 Unsigned 0 32768 - kg Axle 1 load, kg
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 119 Axle 2 Load 2 Unsigned 0 32768 - kg Axle 2 load, kg
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 120 Axle 3 Load 2 Unsigned 0 32768 - kg Axle 3 load, kg
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 121 Axle 4 Load 2 Unsigned 0 32768 - kg Axle 4 load, kg
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 122 Axle 5 Load 2 Unsigned 0 32768 - kg Axle 5 load, kg
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 152 Battery Level 1 Unsigned 0 100 - % Value in percentages, %
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 168 Battery Voltage 2 Unsigned 0 6553 - V Battery Voltage, V
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 325 VIN 17 ASCII 0 0xFF - - VIN number
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 400 Distance to Next Service 4 Unsigned 0 4294967295 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 517 SecurityStateFlags_P4 8 HEX 0 0xffffffffffffffff - - Security state flags protocol 4
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 518 ControlStateFlags_P4 8 HEX 0 0xffffffffffffffff - - Control state flags protocol 4
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 519 IndicatorStateFlags_P4 8 HEX 0 0xffffffffffffffff - - Indicator state flags protocol 4
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 653 HandbrakeActive 1 Unsigned 0 1 - - 0 - Handbrake inactive
1 - Handbrake active
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 654 FrontLeftDoorOpen 1 Unsigned 0 1 - - 0 - Closed
1 - Open
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 655 FrontRightDoorOpen 1 Unsigned 0 1 - - 0 - Closed
1 - Open
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 656 RearLeftDoorOpen 1 Unsigned 0 1 - - 0 - Closed
1 - Open
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 657 RearRightDoorOpen 1 Unsigned 0 1 - - 0 - Closed
1 - Open
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 658 TrunkDoorOpen 1 Unsigned 0 1 - - 0 - Closed
1 - Open
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 659 NeutralGearActive 1 Unsigned 0 1 - - 0 - Inactive
1 - Active
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 660 ParkingGearActive 1 Unsigned 0 1 - - 0 - Inactive
1 - Active
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 661 ReverseGearActive 1 Unsigned 0 1 - - 0 - Inactive
1 - Active
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 662 CarClosed 1 Unsigned 0 1 - - 0 - Closed
1 - Open
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 866 Vehicle Range 4 Unsigned 0 4294967295 - km Information about vehicle range
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 898 LVCAN SSF IgnitionOn 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 903 LVCAN SSF EngineWorkingOnCNG 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 910 SSF FootbrakeActuated 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 911 SSF ClutchPushed 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 912 SSF HazardWarningLights 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 913 SSF EngineCoverOpen 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 914 LVCAN SSF ChargingWirePlugged 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 915 SSF BatteryCharging 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 924 LVCAN SSF CANModuleInSleep 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 927 SSF DriveActive 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 928 CSF ParkingLightsOn 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 929 CSF DippedHeadlightsOn 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 930 CSF FullBeamHeadlightsOn 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 931 CSF RearFogLightsOn 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 932 CSF FrontFogLightsOn 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 936 CSF AirCondOn 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 937 CSF CruiseControlOn 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 940 CSF DriverSeatbelt 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 941 CSF FrontPassSeatbelt 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 942 CSF RearLeftPassSeatbelt 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 943 CSF RearRightPasSeatbelt 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 944 CSF RearCntrPassSeatbelt 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 945 CSF FrontPassengPresent 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 946 LVCAN CSF PTO 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 949 LVCAN CSF CentralDiff4HILocked 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 950 LVCAN CSF CentralDiff4LOLocked 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1086 CSF StartStopSysInactive 1 Unsigned 0 1 - -
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
LVCAN elements 1112 HVBatteryPackVoltage 2 Unsigned 0 65535 - V HV battery pack voltage
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
LVCAN elements 1113 HVBatteryPackCurrent 2 Unsigned 0 65535 - A HV battery pack current
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
LVCAN elements 1116 LVCAN MaxRoadSpeed 1 Unsigned 0 255 - km/h Maximum speed from road signs
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
LVCAN elements 1117 LVCAN ExceededRoadSpeed 1 Unsigned 0 255 - km/h Exceeded speed from road signs
FMBXXX FMB100 FMB110 FMB120 FMB122 FMB125 FMB130 FMB140 FMU120 FMU122 FMU125 FMU126 FMU130 FMC120 FMC122 FMC125 FMC130 FMM125 FMM130 FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
LVCAN elements 1137 FMCAN Steering Wheel Angle 2 Signed -32768 32767 0,1 ° FMCAN Steering Wheel Angle
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
LVCAN elements 1155 HV battery consumed energy 4 Unsigned 0 4294967295 100 kWh Energy consumed from the HV battery
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
LVCAN elements 1156 HV battery recup energy 4 Unsigned 0 4294967295 100 kWh Energy recuperated to the HV battery
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
LVCAN elements 1157 HV battery power 2 Unsigned 0 65535 10 kW Power used from EV battery
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
LVCAN elements 1158 engine oil pressure 2 Unsigned 0 65535 1 kPa Engine oil pressure
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
LVCAN elements 1159 engine oil level 1 Unsigned 0 100 1 % Engine oil level
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
LVCAN elements 1205 LVCAN RSF SpeedLimitSign 1 Unsigned 0 1 - - Information if road sign "Speed limit with value" is recognized/canceled
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1207 LVCAN RSF SpeedExceeded 1 Unsigned 0 1 - - Information if speed is exceeded indicated by road sign "Speed limit with value"
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1270 Engine Oil Temperature 1 Signed -60 127 1 °C Engine oil temperature, °C
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1275 Active Gear Number 1 Unsigned 0 255 - - Active Gear Number
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1276 Front Left Tire Pressure 2 Unsigned 0 65535 0,01 bar Front Left Tire Pressure
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1277 Front Right Tire Pressure 2 Unsigned 0 65535 0,01 bar Front Right Tire Pressure
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1278 Rear Left Tire Pressure 2 Unsigned 0 65535 0,01 bar Rear Left Tire Pressure
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1279 Rear Right Tire Pressure 2 Unsigned 0 65535 0,01 bar Rear Right Tire Pressure
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1331 Transmission selected gear 1 Signed -125 125 1 - Transmission selected gear
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1332 Transmission current gear 1 Signed -125 125 1 - Transmission current gear
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1333 Steering wheel turn counter 1 Signed -32 29 1 - Steering wheel turn counter
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1334 Steering wheel angle sens. typ 1 Unsigned 0 2 1 - SW angle sensor type
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1335 Exhaust fluid tank level 1 Unsigned 0 255 1 % Exhaust fluid tank level
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1336 Bellow pressure FR axle 2 Unsigned 0 65535 0,1 kPa Bellow pressure FR axle
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1337 Bellow pressure FL axle 2 Unsigned 0 65535 0,1 kPa Bellow pressure FL axle
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1338 Bellow pressure RR axle 2 Unsigned 0 65535 0,1 kPa Bellow pressure RR axle
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1339 Bellow pressure RL axle 2 Unsigned 0 65535 0,1 kPa Bellow pressure RL axle
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1340 Heavy duty flags 8 HEX 0 0xffffffffffffffff - - Flags that are related to heavy duty vehicles
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1341 Gaseous fuel rate 2 Unsigned 0 65535 0,1 kg/h Gaseous fuel rate
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1342 Axle 6 Load 2 Unsigned 0 32768 - kg Axle 6 load, kg
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1343 Engine fuel temperature 2 Signed -40 210 1 °C Engine fuel temperature
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1344 Cruise control set speed 1 Unsigned 0 255 1 km/h Cruise control set speed
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1345 Instant fuel economy 1 Unsigned 0 255 1 km/l Instant fuel economy
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1347 PTO speed 2 Unsigned 0 65535 1 RPM PTO speed
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1348 Service brake air press circ 1 2 Unsigned 0 65535 1 kPa Service brake air press circ 1
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1349 Service brake air press circ 2 2 Unsigned 0 65535 1 kPa Service brake air press circ 2
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1350 Front axle speed 1 Unsigned 0 255 1 km/h Front axle speed
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1351 Barometric pressure 1 Unsigned 0 255 1 kPa Barometric pressure
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1352 Engine air intake pressure 2 Unsigned 0 65535 1 kPa Engine air intake pressure
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1353 Engine intake air temperature 2 Signed -40 210 1 °C Engine intake air temperature
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1355 LVCAN CSF SeatOccupancyFL 1 Unsigned 0 1 - - LVCAN CSF SeatOccupancyFL
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1356 CSF SeatOccupancyRL 1 Unsigned 0 1 - - CSF SeatOccupancyRL
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1357 CSF SeatOccupancyRR 1 Unsigned 0 1 - - CSF SeatOccupancyRR
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1358 CSF SWDirectionLeft 1 Unsigned 0 1 - - CSF SWDirectionLeft
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1359 CSF SWDirectionRight 1 Unsigned 0 1 - - CSF SWDirectionRight
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1360 CSF Eco switch 1 Unsigned 0 1 - - CSF Eco switch
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1361 CSF Ramp Wheelchair lift 1 Unsigned 0 1 - - CSF Ramp Wheelchair lift
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1362 LVCAN HDF PosStatOfAllDoors 1 Unsigned 0 1 - - LVCAN HDF PosStatOfAllDoors
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1363 HDF Vehicle motion 1 Unsigned 0 1 - - HDF Vehicle motion
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1365 LVCAN HDF Direction indicator 1 Unsigned 0 1 - - LVCAN HDF Direction indicator
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1364 HDF Vehicle overspeed 1 Unsigned 0 1 - - HDF Vehicle overspeed
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1366 HDF Alternator status 1 1 Unsigned 0 1 - - HDF Alternator status 1
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1367 HDF Alternator status 2 1 Unsigned 0 1 - - HDF Alternator status 2
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1368 HDF Alternator status 3 1 Unsigned 0 1 - - HDF Alternator status 3
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1369 HDF Alternator status 4 1 Unsigned 0 1 - - HDF Alternator status 4
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1370 CSF CC limiter active 1 Unsigned 0 1 - - CSF CC limiter active
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1371 CSF CC standby 1 Unsigned 0 1 - - CSF CC standby
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1372 RSF Lane departure 1 Unsigned 0 1 - - RSF Lane departure
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1373 SSF Door 1 lock status 1 Unsigned 0 1 - - SSF Door 1 lock status
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1374 SSF Door 2 lock status 1 Unsigned 0 1 - - SSF Door 2 lock status
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1375 SSF Door 3 lock status 1 Unsigned 0 1 - - SSF Door 3 lock status
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1376 SSF Door 4 lock status 1 Unsigned 0 1 - - SSF Door 4 lock status
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1377 SSF Door 5 lock status 1 Unsigned 0 1 - - SSF Door 5 lock status
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1396 Ambient Air Temperature 1 Signed -60 127 1 °C Ambient Air Temperature in celsius degrees
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1397 CSF Traction Ctrl En 1 Unsigned 0 1 - - CSF Traction Ctrl En
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1413 LVCAN CSF Left turn signal 1 Unsigned 0 1 - - LVCAN CSF Left turn signal
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1414 LVCAN CSF Right turn signal 1 Unsigned 0 1 - - LVCAN CSF Right turn signal
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1415 LVCAN SSF Charge Port Flap 1 Unsigned 0 1 - - LVCAN SSF Charge Port Flap
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1416 LVCAN CSF Windscreen Wiper 1 Unsigned 0 1 - - LVCAN CSF Windscreen Wiper
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1417 HV Battery Remaining Charge 4 Unsigned 0 4294967296 100 kWh HV battery remaining charge
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters 1418 Electric motor temperature 2 Signed -40 210 1 °C Electric motor temperature
FMBXXX FMB150 FMC150 FMM150 FMB250 FMC250 FMM250
CAN adapters