TFT100 AVL ID List

Revision as of 11:49, 4 July 2024 by Irmantas.K (talk | contribs)

(diff) ← Older revision | Approved revision (diff) | Latest revision (diff) | Newer revision → (diff)
Main Page > E-Mobility Trackers > TFT100 > TFT100 AVL ID List

To search for compatible products, Expand all content

Permanent I/O elements

Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
239 Ignition 1 Unsigned 0 1 - -

0 – Ignition Off
1 – Ignition On

Permanent I/O elements
240 Movement 1 Unsigned 0 1 - -

0 – Movement Off
1 – Movement On

Permanent I/O elements
80 Data Mode 1 Unsigned 0 5 - -

0 – Home On Stop
1 – Home On Moving
2 – Roaming On Stop
3 – Roaming On Moving
4 – Unknown On Stop
5 – Unknown On Moving

Permanent I/O elements
21 GSM Signal 1 Unsigned 0 5 - - Value in scale 1-5 Permanent I/O elements
200 Sleep Mode 1 Unsigned 0 4 - -

0 - Sleep modes disabled
1 – GNSS sleep
2 – Deep sleep
3 – Online deep sleep
4 - Ultra deep sleep

Permanent I/O elements
69 GNSS Status 1 Unsigned 0 3 - -

0 - GNSS OFF
1 – GNSS ON with fix
2 - GNSS ON without fix
3 - GNSS sleep
4 - GNSS OFF, no fix in Static Navigation

Permanent I/O elements
181 GNSS PDOP 2 Unsigned 0 500 0.1 -

Probability

Permanent I/O elements
182 GNSS HDOP 2 Unsigned 0 500 0.1 -

Probability

Permanent I/O elements
24 Speed 2 Unsigned 0 350 - km/h

Value

Permanent I/O elements
205 GSM Cell ID 2 Unsigned 0 65535 - -

GSM base station ID

Permanent I/O elements
206 GSM Area Code 2 Unsigned 0 65535 - -

Location Area code (LAC), it depends on GSM operator. It provides unique number which assigned to a set of base GSM stations.

Permanent I/O elements
67 Battery Voltage 2 Unsigned 0 65535 0.001 V

Voltage

Permanent I/O elements
68 Battery Current 2 Unsigned 0 65535 0.001 A

Current

Permanent I/O elements
113 Battery Level 1 Unsigned 0 100 - % Battery capacity level Permanent I/O elements
66 External Voltage 2 Unsigned 0 65535 0.001 V IO element is used to measure External Voltage, when External Voltage is < 65V. Permanent I/O elements
800 Extended External Voltage 4 Unsigned 0 0xFFFF - V IO element is used to measure External Voltage, when External Voltage is > 65 V. Permanent I/O elements
241 Active GSM Operator 4 Unsigned 0 4294967295 - -

Currently used GSM Operator code

Permanent I/O elements
199 Trip Odometer 4 Unsigned 0 2147483647 - m

Trip Odometer value

Permanent I/O elements
16 Total Odometer 4 Unsigned 0 2147483647 - m Total Odometer value Permanent I/O elements
1 Digital Input 1 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
2 Digital Input 2 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
3 Digital Input 3 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
262 Digital Input 4 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
179 Digital Output 1 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
180 Digital Output 2 1 Unsigned 0 1 - - Logic 0/1 Permanent I/O elements
841 DOUT 1 Overcurrent 1 Unsigned 0 1 - - DOUT 1 Overcurrent IO element is used to indicate overcurrent on Digital Output 1. When Digital Output 1 overcurrent happens, it means that current level is > 300 mA, value is set to 1. Value 1 holds until 5 min timeout runs out. After timeout value is set to 0 if current level is < 300 mA. If current level is still > 300 mA value remains 1. Permanent I/O elements
842 DOUT2 Overcurrent 1 Unsigned 0 1 - - DOUT 2 Overcurrent IO element is used to indicate overcurrent on Digital Output 2. When Digital Output 2 overcurrent happens, it means that current level is > 300 mA, value is set to 1. Value 1 holds until 5 min timeout runs out. After timeout value is set to 0 if current level is < 300 mA. If current level is still > 300 mA value remains 1. Permanent I/O elements
9 Analog Input 1 2 Unsigned 0 65535 0.001 V Voltage Permanent I/O elements
6 Analog Input 2 2 Unsigned 0 65535 0.001 V

Voltage

Permanent I/O elements
839 Extended Analog Input 1 4 Unsigned 0 0xFFFF - V Extended Analog Input 1 IO element is used to measure Analog Input 1 voltage, when Analog Input 1 voltage is > 65 V. Permanent I/O elements
840 Extended Analog Input 2 4 Unsigned 0 0xFFFF - V Extended Analog Input 2 IO element is used to measure Analog Input 2 voltage, when Analog Input 1 voltage is > 65 V. Permanent I/O elements
303 Instant Movement 1 Unsigned 0 1 - - Logic: 0/1 returns movement value Permanent I/O elements
17 Axis X 2 Signed -8000 8000 0.001 G

X axis value

Permanent I/O elements
18 Axis Y 2 Signed -8000 8000 0.001 G

Y axis value

Permanent I/O elements
19 Axis Z 2 Signed -8000 8000 0.001 G

Z axis value

Permanent I/O elements
11 ICCID1 8 Unsigned 0 0xffffffffffffffff - - Value of SIM ICCID, MSB Permanent I/O elements
14 ICCID2 8 Unsigned 0 0xffffffffffffffff - -

Value of SIM ICCID, MSB

Permanent I/O elements
72 Dallas Temperature 1 4 Signed -550 1150 0.1 °C Degrees ( °C ), -55 - +115,
if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850
Permanent I/O elements
73 Dallas Temperature 2 4 Signed -550 1150 0.1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

Permanent I/O elements
74 Dallas Temperature 3 4 Signed -550 1150 0.1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

Permanent I/O elements
75 Dallas Temperature 4 4 Signed -550 1150 0.1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

Permanent I/O elements
76 Dallas Temperature ID 1 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID Permanent I/O elements
77 Dallas Temperature ID 2 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID Permanent I/O elements
79 Dallas Temperature ID 3 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID Permanent I/O elements
71 Dallas Temperature ID 4 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID Permanent I/O elements
78 iButton 8 Unsigned 0 0xffffffffffffffff - - iButton ID Permanent I/O elements
15 Eco Score 2 Unsigned 0 65535 0.01 - Average amount of events on some distance Permanent I/O elements
116 Charger Connected 1 Unsigned 0 1 - - 0 - charger is not connected

1 - charger is connected

Permanent I/O elements
854 User ID 4 Unsigned 0 0xFFFFFFFF - -

This parameter allows to send custom number as AVL ID parameter.
Configurable in Features section.

Permanent I/O elements
387 ISO6709 Coordinates 34 HEX 0 0x7fffffffffffffff - - ISO6709 Coordinates

Latitude, Longitude (in Degrees, Minutes and Seconds) and Altitude:

IO value format: ±DDMMSS.SSSS±DDDMMSS.SSSS±AAA.AAA/

Permanent I/O elements
636 LTE Cell ID 4 Unsigned 0 4294967295 - - LTE Cell ID Permanent I/O elements
288 GSM Cell ID 1 2 Unsigned 0 65535 - - Unique ID of the Cell 1 Permanent I/O elements
291 GSM Cell ID 2 2 Unsigned 0 65535 - - Unique ID of the Cell 2 Permanent I/O elements
294 GSM Cell ID 3 2 Unsigned 0 65535 - - Unique ID of the Cell 3 Permanent I/O elements
297 GSM Cell ID 4 2 Unsigned 0 65535 - - Unique ID of the Cell 4 Permanent I/O elements
287 GSM Cell LAC 1 2 Unsigned 0 65534 - - Location Area Code of the Cell 1 Permanent I/O elements
290 GSM Cell LAC 2 2 Unsigned 0 65534 - - Location Area Code of the Cell 2 Permanent I/O elements
293 GSM Cell LAC 3 2 Unsigned 0 65534 - - Location Area Code of the Cell 3 Permanent I/O elements
296 GSM Cell LAC 4 2 Unsigned 0 65534 - - Location Area Code of the Cell 4 Permanent I/O elements
1200 GSM Cell MNC 1 1 Unsigned - - - - Mobile Network Code of the Cell 1 Permanent I/O elements
1201 GSM Cell MNC 2 1 Unsigned - - - - Mobile Network Code of the Cell 2 Permanent I/O elements
1202 GSM Cell MNC 3 1 Unsigned - - - - Mobile Network Code of the Cell 3 Permanent I/O elements
1203 GSM Cell MNC 4 1 Unsigned - - - - Mobile Network Code of the Cell 4 Permanent I/O elements
286 GSM Signal RX 0 1 Unsigned 0 63 - - GSM Signal of the Cell 0 Permanent I/O elements
289 GSM Signal RX 1 1 Unsigned 0 63 - - GSM Signal of the Cell 1 Permanent I/O elements
292 GSM Signal RX 2 1 Unsigned 0 63 - - GSM Signal of the Cell 2 Permanent I/O elements
295 GSM Signal RX 3 1 Unsigned 0 63 - - GSM Signal of the Cell 3 Permanent I/O elements
298 GSM Signal RX 4 1 Unsigned 0 63 - - GSM Signal of the Cell 4 Permanent I/O elements
25021 LTE Cell ID 1 4 Unsigned 0 4294967295 - - Unique ID of the LTE Cell 1 Permanent I/O elements
25024 LTE Cell ID 2 4 Unsigned 0 4294967295 - - Unique ID of the LTE Cell 2 Permanent I/O elements
25027 LTE Cell ID 3 4 Unsigned 0 4294967295 - - Unique ID of the LTE Cell 3 Permanent I/O elements
25030 LTE Cell ID 4 4 Unsigned 0 4294967295 - - Unique ID of the LTE Cell 4 Permanent I/O elements
25020 LTE Cell LAC 1 2 Unsigned 0 65534 - - Location Area Code of the LTE Cell 1 Permanent I/O elements
25023 LTE Cell LAC 2 2 Unsigned 0 65534 - - Location Area Code of the LTE Cell 2 Permanent I/O elements
25026 LTE Cell LAC 3 2 Unsigned 0 65534 - - Location Area Code of the LTE Cell 3 Permanent I/O elements
25029 LTE Cell LAC 4 2 Unsigned 0 65534 - - Location Area Code of the LTE Cell 4 Permanent I/O elements
25032 LTE Cell MNC 1 1 Unsigned - - - - LTE Mobile Network Code of the Cell 1 Permanent I/O elements
25033 LTE Cell MNC 2 1 Unsigned - - - - LTE Mobile Network Code of the Cell 2 Permanent I/O elements
25034 LTE Cell MNC 3 1 Unsigned - - - - LTE Mobile Network Code of the Cell 3 Permanent I/O elements
25035 LTE Cell MNC 4 1 Unsigned - - - - LTE Mobile Network Code of the Cell 4 Permanent I/O elements
25019 LTE Signal RX 0 1 Unsigned 0 7 - - LTE Signal of the Cell 0 Permanent I/O elements
25022 LTE Signal RX 1 1 Unsigned 0 7 - - LTE Signal of the Cell 1 Permanent I/O elements
25025 LTE Signal RX 2 1 Unsigned 0 7 - - LTE Signal of the Cell 2 Permanent I/O elements
25028 LTE Signal RX 3 1 Unsigned 0 7 - - LTE Signal of the Cell 3 Permanent I/O elements
25031 LTE Signal RX 4 1 Unsigned 0 7 - - LTE Signal of the Cell 4 Permanent I/O elements
399 Time To First Fix 1 Unsigned 0 4294967295 - s Amount of time it took to get first GNSS fix Permanent I/O elements
20015 Modem Uptime 1 Unsigned 0 4294967295 - s Modem Uptime since the last wake up Permanent I/O elements
25015 Modem Uptime 8 Unsigned 0 4294967295 - s Modem Uptime since the last wake up (from FW X.4.10.Rev.00) Permanent I/O elements
20016 LTE RSRP 2 Signed -140 -44 - dBm Reference Signals Received Power Permanent I/O elements
20017 LTE RSRQ 1 Signed -3 -20 - dB Reference Signals Received Quality Permanent I/O elements
25016 LTE RSRP 2 Signed -140 -44 - dBm Reference Signals Received Power (from FW X.4.10.Rev.00) Permanent I/O elements
25017 LTE RSRQ 1 Signed -20 -3 - dB Reference Signals Received Quality (from FW X.4.10.Rev.00) Permanent I/O elements
449 Ignition On Counter value Unsigned 0 2147483647 - s Current value of the counter Permanent I/O elements
10800 EYE Temperature 1 2 Signed -32768 32767 0.01 °C Temperature measured by EYE Sensor 1 Permanent I/O elements
10801 EYE Temperature 2 2 Signed -32768 32767 0.01 °C Temperature measured by EYE Sensor 2 Permanent I/O elements
10802 EYE Temperature 3 2 Signed -32768 32767 0.01 °C Temperature measured by EYE Sensor 3 Permanent I/O elements
10803 EYE Temperature 4 2 Signed -32768 32767 0.01 °C Temperature measured by EYE Sensor 4 Permanent I/O elements
10804 EYE Humidity 1 1 Unsigned 0 100 - % Humidity measured by EYE Sensor 1 Permanent I/O elements
10805 EYE Humidity 2 1 Unsigned 0 100 - % Humidity measured by EYE Sensor 2 Permanent I/O elements
10806 EYE Humidity 3 1 Unsigned 0 100 - % Humidity measured by EYE Sensor 3 Permanent I/O elements
10807 EYE Humidity 4 1 Unsigned 0 100 - % Humidity measured by EYE Sensor 4 Permanent I/O elements
10808 EYE Magnet 1 1 Unsigned 0 1 - - Magnet measured by EYE Sensor by EYE Sensor 1 Permanent I/O elements
10809 EYE Magnet 2 1 Unsigned 0 1 - - Magnet measured by EYE Sensor by EYE Sensor 2 Permanent I/O elements
10810 EYE Magnet 3 1 Unsigned 0 1 - - Magnet measured by EYE Sensor by EYE Sensor 3 Permanent I/O elements
10811 EYE Magnet 4 1 Unsigned 0 1 - - Magnet measured by EYE Sensor by EYE Sensor 4 Permanent I/O elements
10812 EYE Movement 1 2 Unsigned 0 1 - - Movement state measure by EYE Sensor 1 Permanent I/O elements
10813 EYE Movement 2 2 Unsigned 0 1 - - Movement state measure by EYE Sensor 2 Permanent I/O elements
10814 EYE Movement 3 2 Unsigned 0 1 - - Movement state measure by EYE Sensor 3 Permanent I/O elements
10815 EYE Movement 4 2 Unsigned 0 1 - - Movement state measure by EYE Sensor 4 Permanent I/O elements
10816 EYE Pitch 1 1 Signed -90 90 - - Pitch angle measured by EYE Sensor 1 Permanent I/O elements
10817 EYE Pitch 2 1 Signed -90 90 - - Pitch angle measured by EYE Sensor 2 Permanent I/O elements
10818 EYE Pitch 3 1 Signed -90 90 - - Pitch angle measured by EYE Sensor 3 Permanent I/O elements
10819 EYE Pitch 4 1 Signed -90 90 - - Pitch angle measured by EYE Sensor 4 Permanent I/O elements
10820 EYE Low Battery 1 1 Unsigned 0 1 - - Low Battery indication for EYE Sensor 1 Permanent I/O elements
10821 EYE Low Battery 2 1 Unsigned 0 1 - - Low Battery indication for EYE Sensor 2 Permanent I/O elements
10822 EYE Low Battery 3 1 Unsigned 0 1 - - Low Battery indication for EYE Sensor 3 Permanent I/O elements
10823 EYE Low Battery 4 1 Unsigned 0 1 - - Low Battery indication for EYE Sensor 4 Permanent I/O elements
10824 EYE Battery Voltage 1 1 Unsigned 0 65535 - - Battery Voltage of EYE Sensor 1 Permanent I/O elements
10825 EYE Battery Voltage 2 1 Unsigned 0 65535 - - Battery Voltage of EYE Sensor 2 Permanent I/O elements
10826 EYE Battery Voltage 3 1 Unsigned 0 65535 - - Battery Voltage of EYE Sensor 3 Permanent I/O elements
10827 EYE Battery Voltage 4 1 Unsigned 0 65535 - - Battery Voltage of EYE Sensor 4 Permanent I/O elements
10832 EYE Roll 1 2 Signed -180 180 - - Roll angle measured by EYE Sensor 1 Permanent I/O elements
10833 EYE Roll 2 2 Signed -180 180 - - Roll angle measured by EYE Sensor 2 Permanent I/O elements
10834 EYE Roll 3 2 Signed -180 180 - - Roll angle measured by EYE Sensor 3 Permanent I/O elements
10835 EYE Roll 4 2 Signed -180 180 - - Roll angle measured by EYE Sensor 4 Permanent I/O elements
10836 EYE Movement count 1 2 Unsigned 0 65535 - - Movement count measure by EYE Sensor 1 Permanent I/O elements
10837 EYE Movement count 2 2 Unsigned 0 65535 - - Movement count measure by EYE Sensor 2 Permanent I/O elements
10838 EYE Movement count 3 2 Unsigned 0 65535 - - Movement count measure by EYE Sensor 3 Permanent I/O elements
10839 EYE Movement count 4 2 Unsigned 0 65535 - - Movement count measure by EYE Sensor 4 Permanent I/O elements
10840 EYE Magnet count 1 2 Unsigned 0 65535 - - Magnet trigger count measure by EYE Sensor 1 Permanent I/O elements
10841 EYE Magnet count 2 2 Unsigned 0 65535 - - Magnet trigger count measure by EYE Sensor 2 Permanent I/O elements
10842 EYE Magnet count 3 2 Unsigned 0 65535 - - Magnet trigger count measure by EYE Sensor 3 Permanent I/O elements
10843 EYE Magnet count 4 2 Unsigned 0 65535 - - Magnet trigger count measure by EYE Sensor 4 Permanent I/O elements
11317 EYE Sensor List variable length HEX 0 bytes 1024 bytes - - EYE Sensor List Permanent I/O elements

Eventual I/O elements

Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
155 Geofence zone 01 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
156 Geofence zone 02 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
157 Geofence zone 03 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
158 Geofence zone 04 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
159 Geofence zone 05 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
61 Geofence zone 06 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
62 Geofence zone 07 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
63 Geofence zone 08 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
64 Geofence zone 09 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
65 Geofence zone 10 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
70 Geofence zone 11 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
88 Geofence zone 12 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
91 Geofence zone 13 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
92 Geofence zone 14 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
93 Geofence zone 15 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
94 Geofence zone 16 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
95 Geofence zone 17 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
96 Geofence zone 18 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
97 Geofence zone 19 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
98 Geofence zone 20 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
99 Geofence zone 21 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
153 Geofence zone 22 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
154 Geofence zone 23 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
190 Geofence zone 24 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
191 Geofence zone 25 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
192 Geofence zone 26 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
193 Geofence zone 27 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
194 Geofence zone 28 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
195 Geofence zone 29 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
196 Geofence zone 30 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
197 Geofence zone 31 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
198 Geofence zone 32 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
208 Geofence zone 33 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
209 Geofence zone 34 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
216 Geofence zone 35 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
217 Geofence zone 36 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
218 Geofence zone 37 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
219 Geofence zone 38 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
220 Geofence zone 39 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
221 Geofence zone 40 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
222 Geofence zone 41 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
223 Geofence zone 42 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
224 Geofence zone 43 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
225 Geofence zone 44 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
226 Geofence zone 45 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
227 Geofence zone 46 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
228 Geofence zone 47 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
229 Geofence zone 48 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
230 Geofence zone 49 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
231 Geofence zone 50 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements -->
175 Auto Geofence 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

Eventual I/O elements
250 Trip 1 Unsigned 0 1 - - 0 – trip stop
1 – trip start
Eventual I/O elements
255 Overspeeding Event 1 Unsigned 0 255 - km/h

At over speeding start km/h, at over speeding end km/h

Eventual I/O elements
251 Idling 1 Unsigned 0 1 - -

0 – moving
1 – idling

Eventual I/O elements
252 Unplug 1 Unsigned 0 1 - -

0 – battery present
1 – battery unplug

Eventual I/O elements
253 Green driving type 1 Unsigned 1 3 - -

1 – harsh acceleration
2 – harsh braking
3 – harsh cornering

Eventual I/O elements
246 Towing 1 Unsigned 0 1 - -

0 – steady
1 – towing

Eventual I/O elements
247 Crash detection 1 Unsigned 1 5 - -

1 – crash
2 – limited crash trace (device not calibrated)
3 - limited crash trace (device is calibrated)
4 - full crash trace (device not calibrated)
5 - full crash trace (device is calibrated)
6 - crash detected (device not calibrated)

Eventual I/O elements
257 Crash trace data Variable HEX 0 1200 - - Crash trace data Eventual I/O elements
248 Immobilizer 1 Unsigned 0 2 - -

0 – iButton not connected
1 – iButton connected (Immobilizer)
2 – iButton connected (Authorized Driving)

Eventual I/O elements
254 Green Driving Value 1 Unsigned 0 1 0.01 G|rad Depending on green driving type: if harsh acceleration or braking – g*100 (value 123 -> 1.23g), if harsh cornering – degrees (value in radians) Eventual I/O elements
249 Jamming 1 Unsigned 0 1 - - 0 – jamming stop
1 – jamming start
Eventual I/O elements
243 Green driving event duration 2 Unsigned 0 65535 - ms Duration of event that did generate Green driving Eventual I/O elements
236 Alarm 1 Unsigned 0 1 - - 0 – Reserved
1 – Alarm event occurred
Eventual I/O elements
242 ManDown/FallDown 1 Unsigned 0 1 - - 0 – ManDown/FallDown deactivated
1 – ManDown/FalDown is active
Eventual I/O elements
310 Movement Event 1 Unsigned 0 1 - -

0 - Movement event occurred
1 - No Movement event occured

Eventual I/O elements
389 Button Click HEX Unsigned 0x11 0x53 - - Button ID (X) and Action (Y) Value 0xXY
X - button ID:
1 - alarm button
2 - power button
3 - button 1
4 - button 2
5 - button 3
Y - action:
1 - 1 click
2 - 2 clicks
3 - long click
Eventual I/O elements
390 Power Event 1 Unsigned 0 1 - - 1 - Device turned OFF
0 - Device turned ON

TMT250 GH5200

Eventual I/O elements
520 Tamper detection Event 1 Unsigned 0 1 - - 0 - Tamper restore
1 - Tamper alarm

TMT250

Eventual I/O elements
386 Last Known Position 2 Unsigned 0 65535 - s Time in seconds has passed since last GNSS fix
Eventual I/O elements
400 Amber Alert state 1 Unsigned 0 4 - -

0 - Turned Off
1 - Turned On, count down timer started
2 - Amber Alert On button pressed to restart active timer
3 - Alarm
4 - Amber Alert turned On when timer is set to 0 seconds

Eventual I/O elements
401 Amber Alert timer value 2 Unsigned 0 65535 - s

Sends Amber Alert time-out configured value

Eventual I/O elements


403 Heart Rate Alert 1 Unsigned 0 255 - BPM

Sends heart rate (BPM) from Xiaomi Mi Band 2

Eventual I/O elements
236 Alarm 1 Unsigned 0 1 - - 0 – Reserved
1 – Alarm event occurred
Eventual I/O elements
20012 Recovery mode alarm 1 Unsigned 0 2 - - 0 – Reserved
1 – Reserved
2 – Recovery alarm event occurred
Eventual I/O elements
20019 Tamper record event 2 Unsigned 0 3 - - 0 – Holder is removed
1 – Central is attached
2 – Attached to metal surface
3 – Removed from metal surface
Eventual I/O elements
20014 BLE Lost Beacon 1 Unsigned 0 3 - - 0 – Reserved
1 – Reserved
2 – Reserved
3 – BLE Lost Beacon
Eventual I/O elements
463 BLE1 EYE sensor lost alarm 2 HEX - - - - BEEF - BLE1 EYE sensor lost alarm Eventual I/O elements
467 BLE2 EYE sensor lost alarm 2 HEX - - - - BEEF - BLE2 EYE sensor lost alarm Eventual I/O elements
471 BLE3 EYE sensor lost alarm 2 HEX - - - - BEEF - BLE3 EYE sensor lost alarm Eventual I/O elements
475 BLE4 EYE sensor lost alarm 2 HEX - - - - BEEF - BLE4 EYE sensor lost alarm Eventual I/O elements

CAN communication I/O elements

CAN BOSCH I/O elements


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
801 Park Brake 1 Unsigned 0 3 - - Park Brake IO element is used to indicate if parking brake is active, according to CAN signal.

0 - Disengaged
1 - Engaged
2 - Error
3 - Unused

CAN BOSCH
802 Selected 1 Unsigned 0 3 - - Charger state IO element is indicaiting current charger state, according to signal on CAN line.

0 - Disconnected
1 - Connected
2 - Error
3 - Unused

CAN BOSCH
803 Selected Charge Mode 1 Unsigned 0 1 - - Selected Charge mode IO element is indicating which charge mode is currently in use, according to signal on CAN line.

0 - Default
1 - Fast

CAN BOSCH
804 Charger Voltage 2 Unsigned 0 200000 - mV Charger Voltage Setpoint CAN BOSCH
805 Charger Current 2 Unsigned 0 200000 - mA Charger Current Setpoint CAN BOSCH
806 Charger Control Mode 1 Unsigned 0 1 - - Charger Control Mode IO element indicates which cahrger control mode is currently in use.
0-Remote Control C-V-Limiting

1-Open Circuit

CAN BOSCH
807 Charger BMS COM Timeout 1 Unsigned 0 1 - - BMS COM Timeout IO element indicates if BMS COM Timeout has been expired.

0-Expired
1-Not expired

CAN BOSCH
808 Charger CRC Violation 1 Unsigned 0 1 - - Charger CRC Violation IO element indicates if charger CRC violation has happened.

0-No CRC Violation happened
1-CRC Violation happened

CAN BOSCH
809 Charger MC Violation 1 Unsigned 0 1 - - Charger MC Violation IO element indicates if charger MC violation has happened.

0-No MC Violation happened
1-MC Violation happened

CAN BOSCH
810 Charger Status 1 Unsigned 0 7 - - Charger Status IO element indicates current charger status, according to CAN signal.

0-No Errorbr
1-Minimal Current Limiting
2-Reverse Polarity
3-Reserved
4-Cable Voltage Drop
5-Fan Error
6-AC Undervoltage Disconnect
7-Not Ready For Charging

CAN BOSCH
811 Charger Voltage Actual 2 Unsigned 0 200000 - mV Acctual Voltage IO element indicates measured actual charging voltage in mV, according to CAN signal. CAN BOSCH
812 Charger Internal Fault 1 Unsigned 0 1 - mV Charger Internal Fault IO element indicates if charger internal fault happened, according to CAN signal.

0-Internal Fault happened
1-No InternalFault happened

CAN BOSCH
813 Charger Energy 2 Unsigned 0 65535 - Wh Charger Energy IO element indicates currently measured charger energy. CAN BOSCH
814 Charger Current Actual 2 Unsigned 0 65535 - mA Charger Current IO element indicates currently measured charger current. CAN BOSCH
815 Throttle Position 1 Unsigned 0 100 - % Throttle Position IO element indicates currently measured throttle position. CAN BOSCH
816 Brake Pressed 1 Unsigned 0 1 - - Brake Pressed IO element indicates if brake is pressed or not.

0-Brake Pressed
1-Brake Not Pressed

CAN BOSCH
817 Charge Plug 1 Unsigned 0 1 - - Charge Plugged IO element indicates if charger is plugged in or not.

0-Charger Plugged
1-Charger Not Plugged

CAN BOSCH
818 Kill Switch Active 1 Unsigned 0 1 - - Kill Switch Active IO element indicates if kill switch is active or not.

0-Kill Switch Active
1-Kill Switch Not Active

CAN BOSCH
819 Kickstand Release 1 Unsigned 0 1 - - Kickstand Release Status IO element indicates if kickstand released or not.

0-Kickstand Released
1-Kickstand Not Released

CAN BOSCH
820 Powerstrain State 1 Unsigned 0 6 - - Powertrain State IO element indicates current powertrain state.

0-Off
1-Booting
2-Ready
3-Drive
4-Charge
5-Shutdown
6-Error

CAN BOSCH
821 Malfunction Indicator 1 Unsigned 0 1 - - Malfunction Indication IO element indicates if malfunction indicator is active.

0-Malfunction Indicator Not Active
1-Malfunction Indicator Active

CAN BOSCH
822 Current range 2 Unsigned 0 65535 - - Current Range IO element indicates currently measured current range CAN BOSCH
823 SoH Battery 1 Unsigned 0 100 - % SoH Battery IO element indicates currently measured batery SoH. CAN BOSCH
824 SoC Battery 1 Unsigned 0 100 - % SoC Battery IO element indicates currently measured batery SoC. CAN BOSCH
825 Vehicle available 1 Unsigned 0 1 - - Vehicle Available IO element indicates if vehicle is currently available or not.

0-Vehicle Not Available
1-Vehicle Available

CAN BOSCH
826 Charging Active 1 Unsigned 0 1 - - Charging Active IO element indicates if charging is currently active or not.

0-Charging Not Active
1-Charging Active

CAN BOSCH
827 Remaining Charge Time 2 Unsigned 0 65535 - min Remaining Charging Time IO element indicates remaining charging time until vehicle is fully charged. CAN BOSCH
828 Remaining Capacity 2 Unsigned 0 65535 - Ah Remaining Capacity IO element indicates reimaining battery capacity. CAN BOSCH
829 Full Charge Capacity 2 Unsigned 0 65535 - Ah Full Charge Capacity IO element indicates full charge battery capacity. CAN BOSCH
830 Driving direction 1 Unsigned 0 3 - - Driving Direction IO element indicates current vehicle driving direction.

0-Park
1-Reverse
2-Forward
3-Neutral

CAN BOSCH
831 Drive Mode 1 Unsigned 0 3 - - Drive Mode IO element indicates current vehicle drive mode.

0-Go
1-Cruise
2-Boost
3-Reserved1

CAN BOSCH
832 Park Brake Active 1 Unsigned 0 1 - - Park Brake Active IO element indicates if park brake is currently active or not.

0-Park Brake Not Active
1-Park Brake Active

CAN BOSCH
833 Total Distance 4 Unsigned 0 1048575 - km Total Distance IO element indicates measured vehicle total traveled distance. CAN BOSCH
834 Trip Distance 4 Unsigned 0 4095000 - m Trip Distance IO element indicates measured vehicle traveled distance during current trip. CAN BOSCH
835 Vehicle speed 1 Unsigned 0 255 - km/h Vehicle Speed IO element indicates currently measured vehicle speed in km/h. CAN BOSCH
836 Ignition Status 1 Unsigned 0 7 - - Ignition Status IO element current vehicle ignition status.

0-IGN_LOCK
1-IGN_OFF
2-IGN_ACC
3-Free
4-IGN_ON
5-IGN_START
6-LeM_NM:IGN_OFF
7-LeM_NM:IGN_ON

CAN BOSCH
837 Ignition Fast Status 1 Unsigned 0 1 - - Ignition Fast Status IO element indicates if ignition is active or not.

0-Ignition Not Active
1-Ignition Active

CAN BOSCH
838 Power Consumption 2 Unsigned 0 65535 - Wh/km Power Consumption IO element indicates currently measured vehicle power consumption in CAN BOSCH
1121 CAN Unlocked 2 Unsigned 0 1 - - Defines if vehicle is unlocked
CAN BOSCH
1122 BMS2 Temperature Current Max 2 Signed -40 86 - ˚C
CAN BOSCH
1123 BMS2 Temperature Current Min 2 Signed -40 86 - ˚C
CAN BOSCH
1124 BMS2 Voltage Cell Min 4 Unsigned 0 7000 - mV
CAN BOSCH
1125 BMS2 Voltage Cell Max 4 Unsigned 0 7000 - mV
CAN BOSCH
1100 BMS0 Temperature Current Max 2 Signed -40 86 - ˚C
CAN BOSCH
1101 BMS0 Temperature Current Min 2 Signed -40 86 - ˚C
CAN BOSCH
11002 BMS0 Voltage Cell Min 4 Unsigned 0 7000 - mV
CAN BOSCH
11003 BMS0 Voltage Cell Max 4 Unsigned 0 7000 - mV
CAN BOSCH
1104 BMS1 Temperature Current Max 2 Signed -40 86 - ˚C
CAN BOSCH
1105 BMS1 Temperature Current Min 2 Signed -40 86 - ˚C
CAN BOSCH
1106 BMS1 Voltage Cell Min 4 Unsigned 0 7000 - mV
CAN BOSCH
1107 BMS1 Voltage Cell Max 4 Unsigned 0 7000 - mV
CAN BOSCH




CAN Askoll I/O elements


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
804 Charger Voltage 2 Unsigned 0 0xFFFF - mV CAN ASKOLL
805 Charger Current 2 Unsigned 0 0xFFFF - mA CAN ASKOLL
821 Malfunction Indication 1 Unsigned 0 1 - - 0 – Malfunction Indicator Not Active; 1 - Active CAN ASKOLL
822 Current Range 2 Unsigned 0 0xFFFF - km CAN ASKOLL
824 SoC Battery 1 Unsigned 0 100 - % Indicates currently measured batery SoC in %. CAN ASKOLL
824 SoC Battery 1 Unsigned 0 100 - % Indicates currently measured batery SoC. CAN ASKOLL
828 SoC Battery 2 Unsigned 0 0xFFFF - Ah Indicates reimaining battery capacity in Ah. CAN ASKOLL
828 Remaining Battery 2 Unsigned 0 0xFFFF - Ah Indicates reimaining battery capacity. CAN ASKOLL
833 Total Distance 4 Unsigned 0 0xFFFFFFFF - km Indicates measured vehicle total traveled distance. CAN ASKOLL
835 Vehicle Speed 1 Unsigned 0 0xFF - km/h Inicates currently measured vehicle speed. CAN ASKOLL
837 Ignition Fast Status 1 Unsigned 0 1 - - Indicates if ignition is active or not. 0 – not active, 1 - active. CAN ASKOLL
843 Helmet Status 1 Unsigned 0 1 - - Indicates if Helmet is in or not. 0 – not in, 1 – in. CAN ASKOLL
844 Top Case Sensor 1 Unsigned 0 1 - - Indicates if Top Case is open or closed. 0 – closed, 1 – open. CAN ASKOLL
845 Central Stand Up 1 Unsigned 0 1 - - Indicates if central stand is up or down. 0 – down, 1 – up. CAN ASKOLL
846 Vehicle Lock 1 Unsigned 0 1 - - Indicates if vehicle is locked or not. 0 – unlocked, 1 - locked CAN ASKOLL
847 Over-Under Temperature 1 Unsigned 0 1 - - Indicates if there is battery over or under temperature warning. 0 – normal temperature, 1 – over-under temperature CAN ASKOLL
848 Regeneration Disabled 1 Unsigned 0 1 - - Indicates if battery regeneration is disabled. 0 – enabled, 1 – disabled. CAN ASKOLL
849 Battery On/Off 1 Unsigned 0 1 - - Indicates if battery is on or off. 0 – Battery Off, 1 – Battery On CAN ASKOLL
850 Warning UnderVoltage 1 Unsigned 0 1 - - Indicates if there is battery undervoltage warning. 0 – no battery undervoltage, 1 – battery undervoltage. CAN ASKOLL
851 Warning OverVoltage 1 Unsigned 0 1 - - Indicates if there is battery overvoltage warning. 0 – No battery overvoltage, 1 – battery overvoltage. CAN ASKOLL
852 Warning OverCurrent 1 Unsigned 0 1 - - Indicates if there is battery overcurrent warning. 0 – No battery overcurrent, 1 – battery overcurrent. CAN ASKOLL
853 Warning Short Circuit 1 Unsigned 0 1 - - Indicates if there is battery short circuit warning. 0 – No battery short circuit, 1 – battery short circuit. CAN ASKOLL
20015 Seat Sensor 1 Unsigned 0 1 - - Seat Sensor status CAN ASKOLL
20016 Central Stand Lock 1 Unsigned 0 1 - - Central Stand Lock status CAN ASKOLL


Manual CAN I/O elements


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
900 Manual CAN 0 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN0 Manual CAN
901 Manual CAN 1 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN1 Manual CAN
902 Manual CAN 2 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN2 Manual CAN
903 Manual CAN 3 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN3 Manual CAN
904 Manual CAN 4 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN4 Manual CAN
905 Manual CAN 5 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN5 Manual CAN
906 Manual CAN 6 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN6 Manual CAN
907 Manual CAN 7 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN7 Manual CAN
908 Manual CAN 8 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN8 Manual CAN
909 Manual CAN 9 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN9 Manual CAN
910 Manual CAN 10 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN10 Manual CAN
911 Manual CAN 11 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN11 Manual CAN
912 Manual CAN 12 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN12 Manual CAN
913 Manual CAN 13 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN13 Manual CAN
914 Manual CAN 14 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN14 Manual CAN
915 Manual CAN 15 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN15 Manual CAN
916 Manual CAN 16 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN16 Manual CAN
917 Manual CAN 17 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN17 Manual CAN
918 Manual CAN 18 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN18 Manual CAN
919 Manual CAN 19 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN19 Manual CAN
920 Manual CAN 20 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN20 Manual CAN
921 Manual CAN 21 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN21 Manual CAN
922 Manual CAN 22 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN22 Manual CAN
923 Manual CAN 23 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN23 Manual CAN
924 Manual CAN 24 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN24 Manual CAN
925 Manual CAN 25 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN25 Manual CAN
926 Manual CAN 26 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN26 Manual CAN
927 Manual CAN 27 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN27 Manual CAN
928 Manual CAN 28 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN28 Manual CAN
929 Manual CAN 29 8 Unsigned 0 0xFFFFFFFFFFFFFFFF - - Manual CAN29 Manual CAN

Default J1939 I/O elements


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
930 Accelerator Pedal 1 Low Idle Switch 8 Unsigned 0 3 - - Switch signal which indicates the state of the accelerator pedal 1 low idle switch.

0 - Accelerator pedal 1 not in low idle condition

1 - Accelerator pedal 1 in low idle condition

2 - Error

3 - Not available

Default J1939
931 Accelerator Pedal Kickdown Switch 8 Unsigned 0 3 - - Switch signal which indicates whether the accelerator pedal kickdown switch is opened or closed.

0 - Kickdown passive
1 - Kickdown active
2 - Error
3 - Not available

Default J1939
932 Road Speed Limit Status 8 Unsigned 0 3 - - Status (active or not active) of the system used to limit maximum vehicle velocity.

0 - Active
1 - Not Active
2 - Error
3 - Not available

Default J1939
933 Accelerator Pedal 2 Low Idle Switch 8 Unsigned 0 3 - - Switch signal which indicates the state of the accelerator pedal 2 low idle switch.

0 - Accelerator pedal 2 not in low idle condition
1 - Accelerator pedal 2 in low idle condition
2 - Error
3 - Not available

Default J1939
934 Accelerator Pedal Position 1 8 Unsigned 0 100 - % This parameter is intended for the primary accelerator control in an application. Default J1939
936 Engine Percent Load At Current Speed 8 Unsigned 0 250 - % The ratio of actual engine percent torque (indicated) to maximum indicated torque available at the current engine speed, clipped to zero torque during engine braking. Default J1939
937 Remote Accelerator Pedal Position 8 Unsigned 0 100 - % The ratio of actual position of the remote analog engine speed/torque request input device (such as an accelerator pedal or throttle lever) to the maximum position of the input device. Default J1939
938 Accelerator Pedal 2 Position 8 Unsigned 0 10 - % The ratio of actual position of the second analog engine speed/torque request input device (such as an accelerator pedal or throttle lever) to the maximum position of the input device. This parameter is intended for secondary accelerator control in an application. Default J1939
939 Vehicle Acceleration Rate Limit Status 8 Unsigned 0 3 - - Status (active or not active) of the system used to limit maximum forward vehicle acceleration.

0 - Limit not active
1 - Limit active
2 - Reserved
3 - Not available

Default J1939
940 Momentary Engine Maximum Power Enable Feedback 8 Unsigned 0 3 - - Momentarily requesting Engine Maximum Power Enable - feature support feedback

0 - disabled
1 - supported
2 - reserved
3 - don't care

Default J1939
941 DPF Thermal Management Active 8 Unsigned 0 3 - - Indicates that the exhaust temperatures have been elevated for regeneration of the diesel particulate filter aftertreatment system or in preparation of regeneration of the diesel particulate aftertreatment system.

0 - DPF Thermal Management is not active
1 - DPF Thermal Management is active
2 - Reserved
3 - Don't care

Default J1939
942 SCR Thermal Management Active 8 Unsigned 0 3 - - Indicates that the exhaust temperatures have been elevated for regeneration of the SCR aftertreatment system or in preparation of regeneration of the SCR aftertreatment system.

0 - SCR Thermal Management is not active
1 - SCR Thermal Management is active
2 - Reserved
3 - Don't care

Default J1939
943 Actual Maximum Available Engine - Percent Torque 8 Unsigned 0 100 - % This is the maximum amount of torque that the engine can immediately deliver as a percentage of the reference engine torque. Default J1939
944 Estimated Pumping - Percent Torque 8 Unsigned -125 125 - % The calculated torque that indicates the estimated amount of torque loss due to the engine air handling system. Default J1939
945 Engine Torque Mode 8 Unsigned 0 15 - - State signal which indicates which engine torque mode is currently generating, limiting, or controlling the torque.

Mode 0 - “No request”: engine torque may range from 0 to full load only due to low idle governor output.
Modes 1 to 14 indicate that there is either a torque request or the identified function is currently controlling the engine: engine torque may range from 0 (no fueling) to the upper limit.
Mode 15 -

Default J1939
946 Actual Engine - Percent Torque (Fractional) 8 Unsigned 0 0.875 - % This parameter displays an additional torque in percent of the reference engine torque.

0 - +0.000%
1 - +0.125%
...
9 - +0.875%
10 to 15 - not available

Default J1939
947 Driver’s Demand Engine - Percent Torque 8 Unsigned -125 125 - % The requested torque output of the engine by the driver. Default J1939
948 Actual Engine - Percent Torque 8 Unsigned -125 125 - % The calculated output torque of the engine. Default J1939
949 Engine Speed 8 Unsigned 0 8031.875 - rpm Actual engine speed which is calculated over a minimum crankshaft angle of 720 degrees divided by the number of cylinders. Default J1939
950 Source Address of Controlling Device for Engine Control 8 Unsigned 0 255 - SA The source address of the SAE J1939 device currently controlling the engine. Default J1939
951 Engine Starter Mode 8 Unsigned 0 15 - - There are several phases in a starting action and different reasons why a start cannot take place.

0 - start not requested
1 - starter active but not engaged
2 - starter active and engaged
3 - start finished; starter not active after having been actively engaged (after 50ms mode goes to 0)
4 - starter inhibited due to engine already running
5 - starter inhibited due to engine not ready for start (preheating)
6 - starter inhibited due to driveline engaged or other transmission inhibit
7 - starter inhibited due to active immobilizer
8 - starter inhibited due to starter over-temp
9 - starter inhibited due to intake air shutoff valve being active
10 - starter inhibited due to active emissions control system condition
11 - starter inhibited due to ignition key cycle required
12 - starter inhibited - reason unknown
13 - error (legacy implementation only, use 14)
14 - error
15 - not available

Default J1939
952 Engine Demand – Percent Torque 8 Unsigned -125 125 - % The calculated torque that indicates the estimated amount of torque loss due to the engine air handling system. Default J1939
953 Aftertreatment 1 Diesel Oxidation Catalyst Intake Temperature 8 Unsigned -273 1734.96875 - °C Temperature of engine combustion byproducts entering the diesel oxidation catalyst in exhaust bank 1. Default J1939
954 Aftertreatment 1 Diesel Oxidation Catalyst Outlet Temperature 8 Unsigned -273 1734.96875 - °C Temperature of engine combustion byproducts leaving the diesel oxidation catalyst exhaust in exhaust bank 1. Default J1939
955 Aftertreatment 1 Diesel Oxidation Catalyst Differential Pressure 8 Unsigned 0 6425.5 - kPa Exhaust differential pressure measured between the intake and exhaust of a diesel oxidation catalyst in exhaust bank 1. Default J1939
956 Aftertreatment 1 Diesel Oxidation Catalyst Intake Temperature Preliminary FMI 8 Unsigned 0 31 - - Used to identify the applicable J1939-73 FMI detected in the diesel oxidation catalyst intake temperature sensor by the manufacturer’s sensor control software in exhaust bank 1.

A value of 31 is sent to indicate that no failure has been detected or this parameter is not supported.

Default J1939
957 Aftertreatment 1 Diesel Oxidation Catalyst Outlet Temperature Preliminary FMI 8 Unsigned 0 31 - - Used to identify the applicable J1939-73 FMI detected in the diesel oxidation catalyst outlet gas temperature sensor by the manufacturer’s sensor control software in exhaust bank 1.

A value of 31 is sent to indicate that no failure has been detected or this parameter is not supported.

Default J1939
958 Aftertreatment 1 Diesel Oxidation Catalyst Differential Pressure Preliminary FMI 8 Unsigned 0 31 - - Used to identify the applicable J1939-73 FMI detected in the diesel oxidation catalyst differential pressure sensor by the manufacturer’s sensor control software in exhaust bank 1.

A value of 31 is sent to indicate that no failure has been detected or this parameter is not supported.

Default J1939
959 Aftertreatment 1 Diesel Particulate Filter Soot Load Percent 8 Unsigned 0 250 - % Indicates the soot load percent of diesel particulate filter 1. Default J1939
960 Aftertreatment 1 Diesel Particulate Filter Ash Load Percent 8 Unsigned 0 250 - % Indicates the ash load percent of diesel particulate filter 1. Default J1939
961 Aftertreatment 1 Diesel Particulate Filter Time Since Last Active Regeneration 8 Unsigned 0 4211081215 - s Indicates the time since the last active regeneration event of diesel particulate filter 1. Default J1939
962 Aftertreatment 1 Diesel Particulate Filter Soot Load Regeneration Threshold 8 Unsigned 0 160.6375 - % This parameter indicates the value that will first cause DPF regeneration in aftertreatment 1. Default J1939
963 Aftertreatment 1 Exhaust Temperature 2 8 Unsigned -273 1734.96875 - °C The reading from the exhaust temperature sensor located midstream of the other two temperature sensors in the aftertreatment system in exhaust bank 1. Default J1939
964 Aftertreatment 1 Diesel Particulate Filter Intermediate Temperature 8 Unsigned -273 1734.96875 - °C Temperature of engine combustion byproducts at a mid-point in the diesel particulate filter in exhaust bank 1. Default J1939
965 Aftertreatment 1 Diesel Particulate Filter Differential Pressure 8 Unsigned 0 6425.5 - kPa Exhaust differential pressure measured between the intake and exhaust of a diesel particulate filter in exhaust bank 1. Default J1939
966 Aftertreatment 1 Exhaust Temperature 2 Preliminary FMI 8 Unsigned 0 31 - - Used to identify the applicable J1939-73 FMI detected in the exhaust temperature 2 sensor by the manufacturer’s sensor control software in exhaust bank 1. In the case of multiple failures the most severe is communicated.

A value of 31 is sent to indicate that no failure has been detected or this parameter is not supported.

Default J1939
967 Aftertreatment 1 Diesel Particulate Filter Differential Pressure Preliminary FMI 8 Unsigned 0 31 - - Used to identify the applicable J1939-73 FMI detected in the diesel particulate filter differential pressure sensor by the manufacturer’s sensor control software in exhaust bank 1. In the case of multiple failures the most severe is communicated.

A value of 31 is sent to indicate that no failure has been detected or this parameter is not supported.

Default J1939
968 Aftertreatment 1 Diesel Particulate Filter Intermediate Temperature Preliminary FMI 8 Unsigned 0 31 - - Used to identify the applicable J1939-73 FMI detected in the diesel particulate filter intermediate temperature sensor by the manufacturer’s sensor control software in exhaust bank 1. In the case of multiple failures the most severe is communicated.

A value of 31 is sent to indicate that no failure has been detected or this parameter is not supported.

Default J1939
969 Aftertreatment 1 Exhaust Temperature 1 8 Unsigned -273 1734.96875 - °C The reading from the exhaust temperature sensor located farthest upstream in the aftertreatment system in exhaust bank 1. Default J1939
970 Aftertreatment 1 Diesel Particulate Filter Intake Temperature 8 Unsigned -273 1734.96875 - °C Temperature of engine combustion byproducts entering the diesel particulate filter in exhaust bank 1. Default J1939
971 Aftertreatment 1 Exhaust Temperature 1 Preliminary FMI 8 Unsigned 0 31 - - Used to identify the applicable J1939-73 FMI detected in the exhaust temperature 1 sensor by the manufacturer’s sensor control software in exhaust bank 1. In the case of multiple failures the most severe is communicated.

A value of 31 is sent to indicate that no failure has been detected or this parameter is not supported.

Default J1939
972 Aftertreatment 1 Diesel Particulate Filter Intake Temperature Preliminary FMI 8 Unsigned 0 31 - - Used to identify the applicable J1939-73 FMI detected in the diesel particulate filter intake temperature sensor by the manufacturer’s sensor control software in exhaust bank 1. In the case of multiple failures the most severe is communicated.

A value of 31 is sent to indicate that no failure has been detected or this parameter is not supported.

Default J1939
973 Trip Fuel (Gaseous) 8 Unsigned 0 2105540607.5 - kg Total fuel consumed (trip drive fuel + trip PTO governor moving fuel + trip PTO governor non-moving fuel + trip idle fuel) since the last trip reset. Default J1939
974 Total Fuel Used (Gaseous) 8 Unsigned 0 2105540607.5 - kg Total fuel consumed (trip drive fuel + trip PTO governor moving fuel + trip PTO governor non-moving fuel + trip idle fuel) over the life of the engine. Default J1939
989 Trip Vehicle Distance 8 Unsigned 0 526385151.875 - km Distance traveled during all or part of a journey. Default J1939
990 Total Vehicle Distance 8 Unsigned 0 526385151.875 - km Accumulated distance traveled by vehicle during its operation. Default J1939
991 Engine Total Hours of Operation 8 Unsigned 0 210554060.75 - h Accumulated time of operation of engine. Default J1939
992 Engine Total Revolutions 8 Unsigned 0 4211081215000 - r Accumulated number of revolutions of engine crankshaft during its operation. Default J1939
993 Total Vehicle Hours 8 Unsigned 0 210554060.75 - h Accumulated time of operation of vehicle. Default J1939
994 Total Power Takeoff Hours 8 Unsigned 0 210554060.75 - h Accumulated time of operation of power takeoff device. Default J1939
995 Engine Trip Fuel 8 Unsigned 0 2105540607.5 - l Fuel consumed during all or part of a journey. Default J1939
996 Engine Total Fuel Used 8 Unsigned 0 2105540607.5 - l Accumulated amount of fuel used during vehicle operation. Default J1939
1002 Engine Coolant Temperature 8 Unsigned -40 210 - °C Temperature of liquid found in engine cooling system. Default J1939
1003 Engine Fuel 1 Temperature 1 8 Unsigned -40 210 - °C Temperature of fuel (or gas) of the first fuel type. Default J1939
1004 Engine Oil Temperature 1 8 Unsigned -273 1734.96875 - °C Temperature of the engine lubricant. Default J1939
1005 Engine Turbocharger 1 Oil Temperature 8 Unsigned -273 1734.96875 - °C Temperature of the turbocharger lubricant. Default J1939
1006 Engine Intercooler Temperature 8 Unsigned -40 210 - °C Temperature of liquid found in the intercooler located after the turbocharger. Default J1939
1007 Engine Charge Air Cooler Thermostat Opening 8 Unsigned 0 100 - % The current position of the thermostat used to regulate the temperature of the engine charge air cooler.
A value of 0% represents the thermostat being completely closed and 100% represents the thermostat being completely open.
Default J1939
1008 Engine Fuel Delivery Pressure 8 Unsigned 0 1000 - kPa Gage pressure of fuel in system as delivered from supply pump to the injection pump. Default J1939
1009 Engine Extended Crankcase Blow-by Pressure 8 Unsigned 0 12.5 - kPa Differential crankcase blow-by pressure as measured through a tube with a venturi. Default J1939
1010 Engine Oil Level 8 Unsigned 0 100 - % Ratio of current volume of engine sump oil to maximum required volume. Default J1939
1011 Engine Oil Pressure 1 8 Unsigned 0 1000 - kPa Gage pressure of oil in engine lubrication system as provided by oil pump. Default J1939
1012 Engine Crankcase Pressure 1 8 Unsigned -250 251.99 - kPa First instance of the gage pressure inside engine crankcase. Default J1939
1013 Engine Coolant Pressure 1 8 Unsigned 0 500 - kPa Gage pressure of liquid found in engine cooling system. Default J1939
1014 Engine Coolant Level 1 8 Unsigned 0 100 - % Ratio of volume of liquid found in engine cooling system to total cooling system volume. Default J1939
1015 Two Speed Axle Switch 8 Unsigned 0 3 - - Switch signal which indicates the current axle range.

0 - Low speed range
1 - High speed range
2 - Error
3 - Not available

Default J1939
1016 Two Speed Axle Switch 8 Unsigned 0 3 - - Switch signal which indicates when the parking brake is set.

0 - Parking brake not set
1 - Parking brake set
2 - Error
3 - Not available

Default J1939
1017 Cruise Control Pause Switch 8 Unsigned 0 3 - - Switch signal which indicates the position of the Cruise Control Pause Switch used on Remote Cruise Control applications. The Cruise Control Pause Switch signal temporarily disables the Cruise Control function.

0 - Off
1 - On
2 - Error Indicator
3 - Take No Action

Default J1939
1018 Park Brake Release Inhibit Request 8 Unsigned 0 3 - - Park Brake Release Inhibit Request signals the desire that an applied park brake remain applied and limit the ability of the vehicle to be moved.

0 - Park Brake Release Inhibit not requested
1 - Park Brake Release Inhibit requested
2 - SAE reserved
3 - Unavailable

Default J1939
1019 Wheel-Based Vehicle Speed 8 Unsigned 0 250.996 - km/h Speed of the vehicle as calculated from wheel or tailshaft speed. Default J1939
1020 Cruise Control Active 8 Unsigned 0 3 - - Cruise control is switched on.

0 - Cruise control switched off
1 - Cruise control switched on
2 - Error
3 - Not available

Default J1939
1021 Cruise Control Enable Switch 8 Unsigned 0 3 - - Switch signal which indicates that it is possible to manage the cruise control function.

0 - Cruise control disabled
1 - Cruise control enabled
2 - Error
3 - Not available

Default J1939
1022 Brake Switch 8 Unsigned 0 3 - - Switch signal which indicates that the driver operated brake foot pedal is being pressed.

0 - Brake pedal released
1 - Brake pedal depressed
2 - Error
3 - Not Available

Default J1939
1023 Clutch Switch 8 Unsigned 0 3 - - Switch signal which indicates that the clutch pedal is being pressed.

0 - Clutch pedal released
1 - Clutch pedal
2 - Error
3 - Not available

Default J1939
1024 Cruise Control Set Switch 8 Unsigned 0 3 - - Switch signal of the cruise control activator which indicates that the activator is in the position "set."

0 - Cruise control activator not in the position "set"
1 - Cruise control activator in position "set"
2 - Error
3 - Not available

Default J1939
1025 Cruise Control Coast (Decelerate) Switch 8 Unsigned 0 3 - - Switch signal of the cruise control activator which indicates that the activator is in the position "coast (decelerate)."

0 - Cruise control activator not in the position "coast"
1 - Cruise control activator in position "coast"
2 - Error
3 - Not available

Default J1939
1026 Cruise Control Resume Switch 8 Unsigned 0 3 - - Switch signal of the cruise control activator which indicates that the activator is in the position "resume."

0 - Cruise control activator not in the position "resume"
1 - Cruise control activator in position "resume"
2 - Error
3 - Not available

Default J1939
1027 Cruise Control Accelerate Switch 8 Unsigned 0 3 - - Switch signal of the cruise control activator which indicates that the activator is in the position "accelerate."

0 - Cruise control activator not in the position "accelerate"
1 - Cruise control activator in position "accelerate"
2 - Error
3 - Not available

Default J1939
1028 Cruise Control Set Speed 8 Unsigned 0 250.996 - km/h Value of set (chosen) velocity of velocity control system. Default J1939
1029 PTO Governor State 8 Unsigned 0 3 - - Cruise control is switched on. It is not ensured that the engine is controlled by cruise control, as in the case of a large driver's demand the engine is controlled by the driver while cruise control is active (maximum selection of cruise control and driver's demand).

0 - Cruise control switched off
1 - Cruise control switched on
2 - Error
3 - Not available

Default J1939
1030 Cruise Control States 8 Unsigned 0 31 - - This parameter is used to indicate the current state or mode of operation by the power takeoff (PTO) governor.

0 - Off/Disabled
1 - Hold
2 - Remote Hold
3 - Standby
4 - Remote Standby
5 - Set
6 - Decelerate/Coast
7 - Resume
8 - Accelerate
9 - Accelerator Override
10 - Preprogrammed set speed 1
11 - Preprogrammed set speed 2
12 - Preprogrammed set speed 3
13 - Preprogrammed set speed 4
14 - Preprogrammed set speed 5
15 - Preprogrammed set speed 6
16 - Preprogrammed set speed 7
17 - Preprogrammed set speed 8
18 - PTO set speed memory 1
19 - PTO set speed memory 2
20 - PTO set speed memory 3
21 - Reserved
22 - Reserved
23 - Reserved
24 - Reserved
25 - Reserved
26 - Reserved
27 - Reserved
28 - Reserved
29 - Reserved
30 - Reserved
31 - Not available

Default J1939
1031 Engine Idle Increment Switch 8 Unsigned 0 7 - - This parameter is used to indicate the current state, or mode, of operation by the cruise control device. This is a status parameter.

0 - Off/Disabled
1 - Hold
2 - Accelerate
3 - Decelerate
4 - Resume
5 - Set
6 - Accelerator Override
7 - Not available

Default J1939
1032 Engine Idle Decrement Switch 8 Unsigned 0 3 - - Switch signal which indicates the position of the idle increment switch.

0 - Off
1 - On
2 - Error
3 - Not available

Default J1939
1033 Engine Diagnostic Test Mode Switch 8 Unsigned 0 3 - - Switch signal which indicates the position of the idle decrement switch.

0 - Off
1 - On
2 - Error
3 - Not available

Default J1939
1033 Engine Diagnostic Test Mode Switch 8 Unsigned 0 3 - - Switch signal which indicates the position of the engine diagnostic test mode switch.

0 - Off
1 - On
2 - Error
3 - Not available

Default J1939
1034 Engine Shutdown Override Switch 8 Unsigned 0 3 - - Switch signal which indicates the position of the engine shutdown override switch. This switch function allows the operator to override an impending engine shutdown.

0 - Off
1 - On
2 - Error
3 - Not available

Default J1939
1035 Engine Fuel Rate 8 Unsigned 0 3212.75 - l/h Amount of fuel consumed by engine per unit of time. Default J1939
1036 Engine Instantaneous Fuel Economy 8 Unsigned 0 125.498046875 - km/L Current fuel economy at current vehicle velocity. Default J1939
1037 Engine Average Fuel Economy 8 Unsigned 0 125.498046875 - km/L Average of instantaneous fuel economy for that segment of vehicle operation of interest. Default J1939
1038 Engine Throttle Valve 1 Position 1 8 Unsigned 0 100 - % The position of the valve used to regulate the supply of a fluid, usually air or fuel/air mixture, to an engine. 0% represents no supply and 100% is full supply. Default J1939
1039 Engine Throttle Valve 2 Position 8 Unsigned 0 100 - % The sensed position feedback of the valve, coming from a second electrical actuator for a second throttle plate, used to regulate the supply of a fluid, usually air or fuel//air mixture. 0% represents no supply and 100% is full supply. Default J1939
1040 Barometric Pressure 8 Unsigned 0 125 - kPa Absolute air pressure of the atmosphere. Default J1939
1041 Cab Interior Temperature 8 Unsigned -273 1734.96875 - °C Temperature of air inside the part of the vehicle that encloses the driver and vehicle operating controls. Default J1939
1042 Ambient Air Temperature 8 Unsigned -273 1734.96875 - °C Temperature of air surrounding vehicle. Default J1939
1043 Engine Intake 1 Air Temperature 8 Unsigned -40 210 - °C Temperature of air entering vehicle air induction system. Default J1939
1044 Road Surface Temperature 8 Unsigned -273 1734.96875 - °C Indicated temperature of road surface over which vehicle is operating. Default J1939
1045 Aftertreatment 1 Diesel Particulate Filter Intake Pressure 8 Unsigned 0 125 - kPa Exhaust pressure as a result of particle accumulation on filter media placed in the exhaust stream. Default J1939
1046 Engine Intake Manifold #1 Pressure 8 Unsigned 0 500 - kPa The gauge pressure measurement of the air intake manifold. If there are multiple air pressure sensors in the intake stream, this is the last one in flow direction before entering the combustion chamber. This should be the pressure used to drive gauges and displays. Default J1939
1047 Engine Intake Manifold 1 Temperature 8 Unsigned -40 210 - °C Temperature of pre-combustion air found in intake manifold of engine air supply system. Default J1939
1048 Engine Intake Air Pressure 8 Unsigned 0 500 - kPa Absolute air pressure at input port to intake manifold or air box. Default J1939
1049 Engine Air Filter 1 Differential Pressure 8 Unsigned 0 12.5 - kPa Change in engine air system pressure, measured across the filter, due to the filter and any accumulation of solid foreign matter on or in the filter. Default J1939
1050 Engine Exhaust Temperature 8 Unsigned -273 1734.96875 - °C Temperature of combustion byproducts leaving the engine. Default J1939
1051 Engine Coolant Filter Differential Pressure 8 Unsigned 0 125 - kPa Change in coolant pressure, measured across the filter, due to the filter and any accumulation of solid or semisolid matter on or in the filter. Default J1939
1052 SLI Battery 1 Net Current 8 Unsigned -125 125 - A Net flow of electrical current into/out of the first battery or first set of batteries used for starting the engine, for lighting, and for ignition (SLI). Default J1939
1053 Alternator Current 8 Unsigned 0 250 - A Measure of electrical current flow from the alternator. Default J1939
1054 Charging System Potential (Voltage) 8 Unsigned 0 3212.75 - V Electrical potential measured at the charging system output. The charging system may be any device charging the batteries. This includes alternators, generators, solid state charger and other charging devices. Default J1939
1055 Battery Potential / Power Input 1 8 Unsigned 0 3212.75 - V This parameter measures the first source of battery potential as measured at the input of the ECU/actuator etc. coming from one or more batteries, irrespective of the distance between the component and the battery. Default J1939
1056 Key Switch Battery Potential 8 Unsigned 0 3212.75 - V Battery potential measured at the input of the electronic control unit supplied through a key switch or similar switching device. Default J1939
1057 Transmission Clutch 1 Pressure 8 Unsigned 0 4000 - kPa Gage pressure of oil within a wet clutch. Default J1939
1058 Transmission Oil Level 1 8 Unsigned 0 100 - % First instance of a transmission oil level indicator. Conveys the ratio of volume of transmission sump oil to recommended volume. Default J1939
1059 Transmission Filter Differential Pressure 8 Unsigned 0 500 - kPa Change in transmission fluid pressure, measured after the filter, due to accumulation of solid or semisolid material on or in the filter. Default J1939
1060 Transmission 1 Oil Pressure 8 Unsigned 0 4000 - kPa Gage pressure of lubrication fluid in transmission 1, measured after pump. Default J1939
1061 Transmission Oil Temperature 1 8 Unsigned -273 1734.96875 - °C First instance of transmission lubricant temperature. Default J1939
1062 Transmission Oil Level 1 High / Low 8 Unsigned -62.5 62.5 - l First instance of a transmission oil level indicator. Conveys the amount of current volume of transmission sump oil compared to recommended volume. Positive values indicate overfill. Zero means the transmission fluild is filled to the recommended level. Default J1939
1063 Transmission Oil Level 1 Countdown Timer 8 Unsigned 0 15 - - Countdown timer for the first instance of a transmission oil level indicator. Once all vehicle conditions (such as vehicle stopped, etc) are met, some transmissions may require a 'settling time' to allow the fluid level to normalize. This parameter indicates how much of the required settling time remains.

0 - less than 1 minute
1 - One minute
2 - Two minutes
3 - Three minutes
4 - Four minutes
5 - Five minutes
6 - Six minutes
7 - Seven minutes
8 - Eight minutes
9 - Nine minutes
10 - Ten minutes
11 - Eleven minutes
12 - Twelve minutes
13 - Thirteen minutes
14 - Error
15 - Not Available

Default J1939
1064 Transmission Oil Level 1 Measurement Status 8 Unsigned 0 15 - - Measurement status for the first instance of a transmission oil level indicator. If conditions are not acceptable, this parameter conveys to the operator what prevents conditions from being acceptable.

0 - Conditions valid for transmission oil level measurement
1 - Conditions not valid – Settling timer still counting down
2 - Conditions not valid – Transmission in gear
3 - Conditions not valid – Transmission fluid temperature too low
4 - Conditions not valid – Transmission fluid temperature too high
5 - Conditions not valid – Vehicle moving; output shaft speed too high
6 - Conditions not valid – Vehicle not level
7 - Conditions not valid – Engine speed too low
8 - Conditions not valid – Engine speed too high
9 - Conditions not valid – No request for reading
10 - Not defined
11 - Not defined
12 - Not defined
13 - Conditions not valid - Other
14 - Error
15 - Not available

Default J1939
1065 Washer Fluid Level 8 Unsigned 0 100 - % Ratio of volume of liquid to total container volume of fluid reservoir in windshield wash system. Default J1939
1066 Fuel Level 1 8 Unsigned 0 100 - % Ratio of volume of fuel to the total volume of fuel storage container. Default J1939
1067 Engine Fuel Filter Differential Pressure 8 Unsigned 0 500 - kPa Change in fuel delivery pressure, measured across the filter, due to accumulation of solid or semisolid matter on the filter element. Default J1939
1068 Engine Oil Filter Differential Pressure 8 Unsigned 0 125 - kPa Change in engine oil pressure, measured across the filter, due to the filter and any accumulation of solid or semisolid material on or in the filter. Default J1939
1069 Cargo Ambient Temperature 8 Unsigned -273 1734.96875 - °C Temperature of air inside vehicle container used to accommodate cargo. Default J1939
1070 Fuel Level 2 8 Unsigned 0 100 - % Ratio of volume of fuel to the total volume of fuel in the second or right-side storage container. Default J1939
1071 Engine Oil Filter Differential Pressure (Extended Range) 8 Unsigned 0 1250 - kPa Change in engine oil pressure, measured across the filter, due to the filter and any accumulation of solid or semisolid material on or in the filter. Default J1939

FLEX I/O elements


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
815 Throttle Position 8 Unsigned 0 100 - % Throttle position in percentage CAN FLEX
816 Brake Pressed 8 Unsigned 0 1 - - Brake Pressed CAN FLEX
817 Charge Plugged 8 Unsigned 0 1 - - Charge plugged CAN FLEX
818 Kill Switch Active 8 Unsigned 0 1 - - Kill switch status CAN FLEX
819 Kistand Release Status 8 Unsigned 0 1 - - Kistand release status CAN FLEX
820 Powerstrain State 8 Unsigned 0 7 - - Powerstrain state CAN FLEX
821 Malfunction Indication 8 Unsigned 0 1 - - Malfunction indication CAN FLEX
822 Estimated Range 8 Unsigned 0 65535 - km Estimated range CAN FLEX
824 SoC Battery 8 Unsigned 0 100 - % SoC Battery level in percentage CAN FLEX
828 Remaining Capacity 8 Unsigned 0 65535 - Ah Remaining capacity CAN FLEX
829 Full Charge Capacity 8 Unsigned 0 65535 - Ah Full Charge Capacity CAN FLEX
831 Drive Mode 8 Unsigned 0 3 - - Drive Mode state CAN FLEX
833 Total Distance 8 Unsigned 0 1048575 - km Total Distance traveled CAN FLEX
835 Vehicle Speed 8 Unsigned 0 255 - km/h Vehicle speed CAN FLEX
836 Ignition Status 8 Unsigned 0 255 - - Current ignition status CAN FLEX
844 Top Case Sensor 8 Unsigned 0 1 - - Top Case sensor indicator CAN FLEX
1126 Max Available Power 8 Unsigned 0 36000 - W Maximum available power CAN FLEX
1127 Handlebar Lock 8 Unsigned 0 1 - - Handlebar lock status CAN FLEX
1128 Rear Brake Pressed 8 Unsigned 0 1 - - Rear brake status CAN FLEX
1129 COM Error 8 Unsigned 0 1 - - COM Error CAN FLEX
1130 RPM 8 Unsigned 0 1 - rpm RPM CAN FLEX
1131 Torque Current 8 Unsigned 0 1 - A Torque current CAN FLEX
1132 SN High 8 Unsigned - - - - SN High CAN FLEX
1133 SN Low 8 Unsigned - - - - SN Low CAN FLEX
1134 Lowest Battery Voltage 8 Unsigned 0 65535 - mV Lowest battery voltage CAN FLEX
1135 Lowest Battery ID 8 Unsigned - - - - Lowest battery ID CAN FLEX
1136 Highest Battery Voltage 8 Unsigned 0 65535 - mV Highest battery voltage CAN FLEX
1137 Highest Battery ID 8 Unsigned - - - - Highest battery ID CAN FLEX
1138 Highest Mismatch Voltage 8 Unsigned 0 65535 - mV Highest mismatch voltage CAN FLEX
1139 Highest Mismatch ID 8 Unsigned - - - - Highest mismatch ID CAN FLEX
1140 Lowest Battery Temperature 8 Unsigned 0 65535 - °C Lowest battery temperature CAN FLEX
1141 Lowest Temperature Battery ID 8 Unsigned - - - - Lowest temperature battery ID CAN FLEX
1142 Highest Battery Temperature 8 Unsigned 0 65535 - °C Highest battery temperature CAN FLEX
1143 Highest Temperature Battery ID 8 Unsigned - - - - Highest temperature battery ID CAN FLEX
1144 Time To Full Load 8 Unsigned 0 65535 - s Time to full load CAN FLEX
1145 Time To Empty 8 Unsigned 0 65535 - s Time to empty CAN FLEX
1146 Time To Full 8 Unsigned 0 65535 - s Time to full CAN FLEX
1147 Cluster State 8 Unsigned 0 5 - - Cluster state CAN FLEX
1148 Cluster SoC 8 Unsigned 0 255 - % Cluster SoC CAN FLEX
1149 Max Discharge Current 8 Unsigned 0 255 - A Max discharge current CAN FLEX
1150 Recuperation Allowed 8 Unsigned 0 1 - - Recuperation status CAN FLEX
1151 Switch Process Needed 8 Unsigned 0 1 - - Switch process status CAN FLEX
1152 SoC Switch Level 8 Unsigned 0 255 - % SoC switch level CAN FLEX
1153 Part Charge Capacity 8 Unsigned 0 65535 - Ah Part charge capacity CAN FLEX
1154 Cluster Voltage 8 Unsigned 0 65535 - V Cluster voltage CAN FLEX
1155 Cluster Current 8 Unsigned 0 65535 - A Cluster current CAN FLEX
1156 Major Version 8 Unsigned - - - - Major version CAN FLEX
1157 Minor Version 8 Unsigned - - - - Minor version CAN FLEX
1158 Patch Version 8 Unsigned - - - - Patch version CAN FLEX
1159 Recognized Batteries 8 Unsigned 0 255 - - Recognized batteries CAN FLEX
1160 Activated Batteries 8 Unsigned 0 255 - - Activated batteries CAN FLEX
1161 Faulty Batteries 8 Unsigned 0 255 - - Faulty batteries CAN FLEX
1162 Battery 1 Voltage 8 Unsigned 0 65535 - V Battery 1 voltage CAN FLEX
1163 Battery 1 Current 8 Unsigned 0 65535 - A Battery 1 current CAN FLEX
1164 Battery 1 State 8 Unsigned 0 65535 - - Battery 1 State CAN FLEX
1165 Battery 1 SoC 8 Unsigned 0 255 - % Battery 1 SoC CAN FLEX
1166 Battery 1 Temperature 1 8 Unsigned 0 127 - °C Battery 1 temperature 1 CAN FLEX
1167 Battery 1 Temperature 2 8 Unsigned 0 127 - °C Battery 1 temperature 2 CAN FLEX
1168 Battery 1 Power Stage Temp 8 Unsigned 0 127 - °C Battery 1 power stage temp 1 CAN FLEX
1169 Battery 1 Remaining Capacity 8 Unsigned 0 65535 - mAh Battery 1 remaining capacity CAN FLEX
1170 Battery 2 Voltage 8 Unsigned 0 65535 - V Battery 2 voltage CAN FLEX
1171 Battery 2 Current 8 Unsigned 0 65535 - A Battery 2 current CAN FLEX
1172 Battery 2 State 8 Unsigned 0 65535 - - Battery 2 state CAN FLEX
1173 Battery 2 SoC 8 Unsigned 0 255 - % Battery 2 SoC CAN FLEX
1174 Battery 2 Temperature 1 8 Unsigned 0 127 - °C Battery 2 temperature 1 CAN FLEX
1175 Battery 2 Temperature 2 8 Unsigned 0 127 - °C Battery 2 temperature 2 CAN FLEX
1176 Battery 2 Power Stage Temp 8 Unsigned 0 127 - °C Battery 2 power stage temp CAN FLEX
1177 Battery 2 Remaining Capacity 8 Unsigned 0 65535 - mAh Battery 2 remaining capacity CAN FLEX
1178 Battery ID 0 Error Code 8 Unsigned - - - - Battery ID 0 error code CAN FLEX
1179 Battery ID 1 Error Code 8 Unsigned - - - - Battery ID 1 error code CAN FLEX
1180 Cluster Error Code 8 Unsigned - - - - Cluster error code CAN FLEX
1181 Max Charge Current 8 Unsigned 0 65535 - A Max charge current CAN FLEX
1182 Lowest Battery 2 Temperature 8 Unsigned 0 65535 - °C Lowest battery 2 voltage CAN FLEX
1183 Highest Battery 2 Temperature 8 Unsigned 0 65535 - °C Highest battery 2 temperature CAN FLEX
1184 Lowest Battery 2 Voltage 8 Unsigned 0 65535 - mV Lowest battery 2 voltage CAN FLEX
1185 Highest Battery 2 Voltage 8 Unsigned 0 65535 - mV Highest battery 2 voltage CAN FLEX

RS485 communication I/O elements

SuperSoco I/O elements


Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
855 Power 1 Unsigned 0 1 - - 0 - Power Off
1 - Power ON
RS485 SUPERSOCO
856 Current Trip Range 4 Unsigned 0 4294967295 - - Current trip Range IO element indicates currently measured current range RS485 SUPERSOCO
857 Total Trip Range 4 Unsigned 0 4294967295 - - Total trip Range IO element indicates currently measured total range RS485 SUPERSOCO
858 Battery Capacity 1 Unsigned 0 255 - - Battery capacity I/O element shows battery capacity left. RS485 SUPERSOCO
859 Low Voltage 1 Unsigned 0 1 - - Low Voltage status RS485 SUPERSOCO
860 High Temperature 1 Unsigned 0 1 - - High Temperature status RS485 SUPERSOCO
861 Upload Time 1 Unsigned 0 1 - - Upload time status RS485 SUPERSOCO
862 Moving Abnormal 1 Unsigned 0 1 - - Moving abnormal status RS485 SUPERSOCO
863 Range 2 Unsigned 0 65535 - km Range indicator RS485 SUPERSOCO
864 Lock Status 1 Unsigned 0 1 - - Lock status RS485 SUPERSOCO
865 Vehicle FW version 2 Unsigned 0 65535 - - Vehicle FW version RS485 SUPERSOCO
866 Total Range 4 Unsigned 0 4294967295 - m Total range indicator RS485 SUPERSOCO
867 Battery Energy 2 Unsigned 0 0 - kW*h Battery Energy indicator RS485 SUPERSOCO
868 Power System Error 8 Unsigned 0 18446744073709551615 - - RS485 SUPERSOCO
869 Power Train Error 8 Unsigned 0 18446744073709551615 - - RS485 SUPERSOCO
870 Instrument System Error 8 Unsigned 0 18446744073709551615 - - RS485 SUPERSOCO

BLE Sensor I/O elements

Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
25 BLE Temperature #1 2 Signed -400 12050 - °C Degrees ( °C ), -40 - +125;

Error codes:
32767 - sensor not found
32766 - failed sensor data parsing
32765 - abnormal sensor state

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
26 BLE Temperature #2 2 Signed -400 12050 - °C Degrees ( °C ), -40 - +125;

Error codes:
32767 - sensor not found
32766 - failed sensor data parsing
32765 - abnormal sensor state

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
27 BLE Temperature #3 2 Signed -400 12050 - °C Degrees ( °C ), -40 - +125;

Error codes:
32767 - sensor not found
32766 - failed sensor data parsing
32765 - abnormal sensor state

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
28 BLE Temperature #4 2 Signed -400 12050 - °C Degrees ( °C ), -40 - +125;

Error codes:
32767 - sensor not found
32766 - failed sensor data parsing
32765 - abnormal sensor state

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
29 BLE Battery #1 1 Unsigned 0 100 - % Battery level of sensor #1

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
20 BLE Battery #2 1 Unsigned 0 100 - % Battery level of sensor #2

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
22 BLE Battery #3 1 Unsigned 0 100 - % Battery level of sensor #3

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
23 BLE Battery #4 1 Unsigned 0 100 - % Battery level of sensor #4

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
86 BLE Humidity #1 2 Unsigned 0 1000 - %RH Humidity

Error codes:
32767 - sensor not found
32766 - failed sensor data parsing
32765 - abnormal sensor state

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
104 BLE Humidity #2 2 Unsigned 0 1000 - %RH Humidity

Error codes:
32767 - sensor not found
32766 - failed sensor data parsing
32765 - abnormal sensor state

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
106 BLE Humidity #3 2 Unsigned 0 1000 - %RH Humidity

Error codes:
32767 - sensor not found
32766 - failed sensor data parsing
32765 - abnormal sensor state

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
108 BLE Humidity #4 2 Unsigned 0 1000 - %RH Humidity

Error codes:
32767 - sensor not found
32766 - failed sensor data parsing
32765 - abnormal sensor state

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
331 BLE 1 Custom #1 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
463 BLE 1 Custom #2 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
464 BLE 1 Custom #3 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
465 BLE 1 Custom #4 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
466 BLE 1 Custom #5 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
332 BLE 2 Custom #1 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
467 BLE 2 Custom #2 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
468 BLE 2 Custom #3 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
469 BLE 2 Custom #4 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
470 BLE 2 Custom #5 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
333 BLE 3 Custom #1 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
471 BLE 3 Custom #2 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
472 BLE 3 Custom #3 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
473 BLE 3 Custom #4 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
474 BLE 3 Custom #5 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
334 BLE 4 Custom #1 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
475 BLE 4 Custom #2 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
476 BLE 4 Custom #3 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
477 BLE 4 Custom #4 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
478 BLE 4 Custom #5 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
385 Beacon ID's - HEX - - - - Data structure:

Data part: 1 Byte
Beacon flag: 1 Byte
Beacon ID (iBeacon/Eddystone): 20 Bytes/16 Bytes
Signal strength: 1 Byte

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
874 Bluetooth Home Zone Violation state 1 HEX - 0x0F - -

Bits describe the causes of violations:
0 - Back to Bluetooth Home Zone
1 - Movement (Only for Ela MOV sensor)
2 - RSSI threshold violation
4 - BLE missing

GH5200

Bluetooth Low Energy
889 Proximity Violation state 1 HEX - 0x0F - -

Bits describe the causes of violations:
1 - RSSI threshold violation
0 - End of RSSI violation

GH5200

Bluetooth Low Energy
875 Proximity violation source with Teltonika devices 12 ASCII - - - - MAC address which violates personal space

Example of encoded HEX ASCII text:
HEX: 44 35 41 34 31 42 38 42 31 30 37 35
HEX ASCII to text: D5A41B8B1075
(NOTE! From firmware version Rev.329 device sends IMEI instead of MAC address)
Example:
HEX -> ASCII (String)
3031343731353942383241454643 -> 0147159B82AEFC
HEX -> DEC
0147159B82AEFC -> 359633105628924

GH5200

Bluetooth Low Energy
876 Proximity violation source with iBeacons 32 ASCII - - - - Example of UUID encoded HEX to ASCII format:

HEX: 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 42 42 43 43 35 32 36 46 36 46 36 44 33 31
HEX to ASCII format: AAAAAAAAAAAAAAAAAABBCC526F6F6D31

GH5200

Bluetooth Low Energy
890 Proximity duration 2 Unsigned 0 65535 - s Violation time in seconds.
Included as an IO element with AVL ID 875

GH5200

Bluetooth Low Energy
891 BLE MAC address 12 ASCII - - - - BLE MAC address of device.

Example of encoded HEX ASCII text:
HEX: 44 35 41 34 31 42 38 42 31 30 37 35
HEX ASCII to text: D5A41B8B1075

GH5200

Bluetooth Low Energy
263 BT Status 1 Unsigned 0 4 - - 0 - BT is disabled
1 - BT Enabled, not device connected
2 - Device connected, BTv3 Only
3 - Device connected, BLE only
4 - Device connected, BLE + BT
Bluetooth Low Energy
871 BLE Lock Status 1 Unsigned 0 1 - - 0 – Unlocked
1 – Locked On
Bluetooth Low Energy
872 BLE Lock Battery 1 Unsigned 0 100 - % Battery level of Bluetooth lock Bluetooth Low Energy
873 BLE Lock Discovered 1 Unsigned 0 1 - 1 - Bluetooth lock Discovered Bluetooth Low Energy
585 BLE Devices - HEX - - - - Data structure:

Number of beacons: 1 Byte
MAC Adress: 6 Bytes
RSSI: 1 Byte
Slot: 1 Byte
Main size: 1 Byte
Main Data: 0-32 Bytes
Additional Data size: 1 Byte
Additional Data: 0-32 Bytes

TMT250 GH5200

Bluetooth Low Energy