Product change notifications (PCN) is the way of informing customers of upcoming changes related to Teltonika products. This includes outward appearance adjustments, hardware improvements, firmware changes, changes to package contents, etc.
This page stores information regarding changes to the FMM230 tracking device. Below you will find a list of both upcoming and already implemented changes sorted from newest to oldest (top to bottom).
We would like to inform you that starting from August, 2024, there will be changes in the PCB's modification of our FMM230 devices. These changes affect FMM130, FMM230 and FMM125 devices.
Change description
Change type
Mechanical part changes
Detailed description
Change of mechanical components within PCB.
Old Version:
New Version:
Change reasons
FMU differences
Modem position moved
New BT antenna
Modem USB test points moved
Added QR code on top side of PCB
DOUT changed to discrete
Electrolytic caps changed to ceramics
Added battery TP
Changed fuse footprint
Removed external GNSS antenna cutout
Product release date
August, 2024
Affected products
Model
Affected order codes: FMM130******* order codes
Affected order codes: FMM130******* order codes
FMM130
PCB's mechanical part changes
PCB's mechanical part changes
Change impact
Risk assessment
No risk factors encountered with this change.
Suggested implementation plan: Due to changes in device appearance we strongly recommend to contact your customs agent with our change log information, to avoid any unexpected delays in customs clearance process.
Suggested implementation plan
If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above.
2024.05.13: Base firmware update
We would like to inform you about the base firmware update for FMM230 starting from June, 2024. New production firmware version will be 03.29.00.Rev.18
Change description
Change type
Firmware update
Detailed description
Key improvements from last production firmware are listed in errata: FMM230 firmware errata
Old version: 03.29.00.Rev.13
New version: 03.29.00.Rev.18
Change reasons
FMM230 base firmware version update for modifications with BG95-M3 module
Product release date
2024 June
Affected products
Model
Affected order codes
Order code changes
FMM230
FMM230LN**** with 03.29.00.Rev.13 firmware
FMM23094**** with 03.29.00.Rev.13 firmware
New firmware version
Change impact
Risk assessment
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
Suggested implementation plan
If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
2024.01.22: Modified battery placement within the casing
We would like to inform you that starting from January 2024, there will be a small change in the FMM230 devices casing. We have adjusted the battery placement and increased PCB guide height within casing. This modification was essential to enhance our manufacturing process.
Change description
Change type
Optimizing robotic battery placement process within casing
Detailed description
The modifications will not impact the place of the battery or PCB within the FMM230 device.
Old Version:
New Version:
Change reasons
Modified battery placement within the casing.
PCB guide height increased for easier assembly.
Improved manufacturing process.
Product release date
January, 2024
Affected products
Model
Affected order codes
Order code changes
FMM230
FMM230 all codes
Modified battery placement and PCB guide height within the casing.
Change impact
Risk assessment
During transition period clients might receive devices with previous casing design. The transition period can last from January to February inclusive.
Suggested implementation plan
No implementation plan is needed.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification – Teltonika may accept that this change has tactically accepted and can implement the change as indicated above.
2024.01.26: Base firmware update
We would like to inform you about the base firmware update for FMM230 starting from January 26th, 2024. New production firmware version will be 03.29.00.Rev.14
Change description
Change type
Firmware update
Detailed description
Key improvements from last production firmware are listed in errata: FMM230_firmware_errata
Old version:
FMM230 03.27.13.Rev.03
New version:
FMM230 03.29.00.Rev.14
Change reasons
FMM230 base firmware version update
Product release date
2024 January
Affected products
Model
Affected order codes
Order code changes
FMM230
FMM230******* order codes with base Firmware
Update firmware
Change impact
Risk assessment
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
Suggested implementation plan
If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above
2023.12.13: Certification Engraving Update
Change description
Change type
Internal
Detailed description
The specifications of laser engraving devices have undergone modifications subsequent to their certification by Anatel and Bluetooth® SIG, ensuring compliance with rigorous standards. These changes affect FMM130-QG5 and FMM230-Q3IB0 devices.
Old laser engraving:
New laser engraving:
Change reasons
The devices have received approval from both Anatel certification and compliance with the Bluetooth® SIG standard. These changes affect FMM130-QG5 and FMM230-Q3IB0 devices.
Release date
December, 2023
Affected products
Model
Affected order codes
Order code changes
FMM230
FMM230-Q3IB0
Updated laser engraving.
Change impact
Risk assessment
During the transition period clients might receive devices with old laser engraving.
Suggested implementation plan
No implementation plan is needed.
Acknowledgement of PCN receipt
If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has tactically accepted and can implement the change as indicated above.
2022.09.19: Base firmware update
We would like to inform you about the base firmware update for FMM230 starting from October 1st, 2022. New production firmware version will be 03.27.13.Rev.03
Client's special firmware versions or order codes with special firmware will not be updated to latest base firmware automatically. During the transition period clients might receive devices with previous Firmware version used in manufacture.
Suggested implementation plan
If you are using special firmware version and would like an upgrade to new features of latest base firmware, please contact your Teltonika sales manager.