GH5200 AVL ID List

Main Page > Autonomous Trackers > GH5200 > GH5200 AVL ID List

To search for compatible products, Expand all content

Permanent I/O elements

Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
239 Ignition 1 Unsigned 0 1 - -

0 – Ignition Off
1 – Ignition On

Permanent I/O elements
240 Movement 1 Unsigned 0 1 - -

0 – Movement Off
1 – Movement On

Permanent I/O elements
80 Data Mode 1 Unsigned 0 5 - -

0 – Home On Stop
1 – Home On Moving
2 – Roaming On Stop
3 – Roaming On Moving
4 – Unknown On Stop
5 – Unknown On Moving

Permanent I/O elements
21 GSM Signal 1 Unsigned 0 5 - - Value in scale 1-5 Permanent I/O elements
200 Sleep Mode 1 Unsigned 0 4 - -

0 - Sleep modes disabled
1 – GNSS sleep
2 – Deep sleep
3 – Online deep sleep
4 - Ultra deep sleep

Permanent I/O elements
69 GNSS Status 1 Unsigned 0 3 - -

0 - GNSS OFF
1 – GNSS ON with fix
2 - GNSS ON without fix
3 - GNSS sleep
4 - GNSS OFF, no fix in Static Navigation

Permanent I/O elements
181 GNSS PDOP 2 Unsigned 0 500 0.1 -

Probability

Permanent I/O elements
182 GNSS HDOP 2 Unsigned 0 500 0.1 -

Probability

Permanent I/O elements
24 Speed 2 Unsigned 0 350 - km/h

Value

Permanent I/O elements
205 GSM Cell ID 2 Unsigned 0 65535 - -

GSM base station ID

Permanent I/O elements
206 GSM Area Code 2 Unsigned 0 65535 - -

Location Area code (LAC), it depends on GSM operator. It provides unique number which assigned to a set of base GSM stations.

Permanent I/O elements
67 Battery Voltage 2 Unsigned 0 65535 0.001 V

Voltage

Permanent I/O elements
68 Battery Current 2 Unsigned 0 65535 0.001 A

Current

Permanent I/O elements
113 Battery Level 1 Unsigned 0 100 - % Battery capacity level Permanent I/O elements
66 External Voltage 2 Unsigned 0 65535 0.001 V IO element is used to measure External Voltage, when External Voltage is < 65V. Permanent I/O elements
800 Extended External Voltage 4 Unsigned 0 0xFFFF - V IO element is used to measure External Voltage, when External Voltage is > 65 V. Permanent I/O elements
241 Active GSM Operator 4 Unsigned 0 4294967295 - -

Currently used GSM Operator code

Permanent I/O elements
199 Trip Odometer 4 Unsigned 0 2147483647 - m

Trip Odometer value

Permanent I/O elements
16 Total Odometer 4 Unsigned 0 2147483647 - m Total Odometer value Permanent I/O elements
1 Digital Input 1 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
2 Digital Input 2 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
3 Digital Input 3 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
262 Digital Input 4 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
179 Digital Output 1 1 Unsigned 0 1 - -

Logic: 0/1

Permanent I/O elements
180 Digital Output 2 1 Unsigned 0 1 - - Logic 0/1 Permanent I/O elements
841 DOUT 1 Overcurrent 1 Unsigned 0 1 - - DOUT 1 Overcurrent IO element is used to indicate overcurrent on Digital Output 1. When Digital Output 1 overcurrent happens, it means that current level is > 300 mA, value is set to 1. Value 1 holds until 5 min timeout runs out. After timeout value is set to 0 if current level is < 300 mA. If current level is still > 300 mA value remains 1. Permanent I/O elements
842 DOUT2 Overcurrent 1 Unsigned 0 1 - - DOUT 2 Overcurrent IO element is used to indicate overcurrent on Digital Output 2. When Digital Output 2 overcurrent happens, it means that current level is > 300 mA, value is set to 1. Value 1 holds until 5 min timeout runs out. After timeout value is set to 0 if current level is < 300 mA. If current level is still > 300 mA value remains 1. Permanent I/O elements
9 Analog Input 1 2 Unsigned 0 65535 0.001 V Voltage Permanent I/O elements
6 Analog Input 2 2 Unsigned 0 65535 0.001 V

Voltage

Permanent I/O elements
839 Extended Analog Input 1 4 Unsigned 0 0xFFFF - V Extended Analog Input 1 IO element is used to measure Analog Input 1 voltage, when Analog Input 1 voltage is > 65 V. Permanent I/O elements
840 Extended Analog Input 2 4 Unsigned 0 0xFFFF - V Extended Analog Input 2 IO element is used to measure Analog Input 2 voltage, when Analog Input 1 voltage is > 65 V. Permanent I/O elements
303 Instant Movement 1 Unsigned 0 1 - - Logic: 0/1 returns movement value Permanent I/O elements
17 Axis X 2 Signed -8000 8000 0.001 G

X axis value

Permanent I/O elements
18 Axis Y 2 Signed -8000 8000 0.001 G

Y axis value

Permanent I/O elements
19 Axis Z 2 Signed -8000 8000 0.001 G

Z axis value

Permanent I/O elements
11 ICCID1 8 Unsigned 0 0xffffffffffffffff - - Value of SIM ICCID, MSB Permanent I/O elements
14 ICCID2 8 Unsigned 0 0xffffffffffffffff - -

Value of SIM ICCID, MSB

Permanent I/O elements
72 Dallas Temperature 1 4 Signed -550 1150 0.1 °C Degrees ( °C ), -55 - +115,
if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850
Permanent I/O elements
73 Dallas Temperature 2 4 Signed -550 1150 0.1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

Permanent I/O elements
74 Dallas Temperature 3 4 Signed -550 1150 0.1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

Permanent I/O elements
75 Dallas Temperature 4 4 Signed -550 1150 0.1 °C Degrees ( °C ), -55 - +115,

if 850 – Sensor not ready
if 2000 – Value read error
if 3000 – Not connected
if 4000 – ID failed
if 5000 – same as 850

Permanent I/O elements
76 Dallas Temperature ID 1 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID Permanent I/O elements
77 Dallas Temperature ID 2 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID Permanent I/O elements
79 Dallas Temperature ID 3 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID Permanent I/O elements
71 Dallas Temperature ID 4 8 Unsigned 0 0xffffffffffffffff - - Dallas sensor ID Permanent I/O elements
78 iButton 8 Unsigned 0 0xffffffffffffffff - - iButton ID Permanent I/O elements
15 Eco Score 2 Unsigned 0 65535 0.01 - Average amount of events on some distance Permanent I/O elements
116 Charger Connected 1 Unsigned 0 1 - - 0 - charger is not connected

1 - charger is connected

Permanent I/O elements
854 User ID 4 Unsigned 0 0xFFFFFFFF - -

This parameter allows to send custom number as AVL ID parameter.
Configurable in Features section.

Permanent I/O elements
387 ISO6709 Coordinates 34 HEX 0 0x7fffffffffffffff - - ISO6709 Coordinates

Latitude, Longitude (in Degrees, Minutes and Seconds) and Altitude:

IO value format: ±DDMMSS.SSSS±DDDMMSS.SSSS±AAA.AAA/

Permanent I/O elements
636 LTE Cell ID 4 Unsigned 0 4294967295 - - LTE Cell ID Permanent I/O elements
288 GSM Cell ID 1 2 Unsigned 0 65535 - - Unique ID of the Cell 1 Permanent I/O elements
291 GSM Cell ID 2 2 Unsigned 0 65535 - - Unique ID of the Cell 2 Permanent I/O elements
294 GSM Cell ID 3 2 Unsigned 0 65535 - - Unique ID of the Cell 3 Permanent I/O elements
297 GSM Cell ID 4 2 Unsigned 0 65535 - - Unique ID of the Cell 4 Permanent I/O elements
287 GSM Cell LAC 1 2 Unsigned 0 65534 - - Location Area Code of the Cell 1 Permanent I/O elements
290 GSM Cell LAC 2 2 Unsigned 0 65534 - - Location Area Code of the Cell 2 Permanent I/O elements
293 GSM Cell LAC 3 2 Unsigned 0 65534 - - Location Area Code of the Cell 3 Permanent I/O elements
296 GSM Cell LAC 4 2 Unsigned 0 65534 - - Location Area Code of the Cell 4 Permanent I/O elements
1200 GSM Cell MNC 1 1 Unsigned - - - - Mobile Network Code of the Cell 1 Permanent I/O elements
1201 GSM Cell MNC 2 1 Unsigned - - - - Mobile Network Code of the Cell 2 Permanent I/O elements
1202 GSM Cell MNC 3 1 Unsigned - - - - Mobile Network Code of the Cell 3 Permanent I/O elements
1203 GSM Cell MNC 4 1 Unsigned - - - - Mobile Network Code of the Cell 4 Permanent I/O elements
286 GSM Signal RX 0 1 Unsigned 0 63 - - GSM Signal of the Cell 0 Permanent I/O elements
289 GSM Signal RX 1 1 Unsigned 0 63 - - GSM Signal of the Cell 1 Permanent I/O elements
292 GSM Signal RX 2 1 Unsigned 0 63 - - GSM Signal of the Cell 2 Permanent I/O elements
295 GSM Signal RX 3 1 Unsigned 0 63 - - GSM Signal of the Cell 3 Permanent I/O elements
298 GSM Signal RX 4 1 Unsigned 0 63 - - GSM Signal of the Cell 4 Permanent I/O elements
25021 LTE Cell ID 1 4 Unsigned 0 4294967295 - - Unique ID of the LTE Cell 1 Permanent I/O elements
25024 LTE Cell ID 2 4 Unsigned 0 4294967295 - - Unique ID of the LTE Cell 2 Permanent I/O elements
25027 LTE Cell ID 3 4 Unsigned 0 4294967295 - - Unique ID of the LTE Cell 3 Permanent I/O elements
25030 LTE Cell ID 4 4 Unsigned 0 4294967295 - - Unique ID of the LTE Cell 4 Permanent I/O elements
25020 LTE Cell LAC 1 2 Unsigned 0 65534 - - Location Area Code of the LTE Cell 1 Permanent I/O elements
25023 LTE Cell LAC 2 2 Unsigned 0 65534 - - Location Area Code of the LTE Cell 2 Permanent I/O elements
25026 LTE Cell LAC 3 2 Unsigned 0 65534 - - Location Area Code of the LTE Cell 3 Permanent I/O elements
25029 LTE Cell LAC 4 2 Unsigned 0 65534 - - Location Area Code of the LTE Cell 4 Permanent I/O elements
25032 LTE Cell MNC 1 1 Unsigned - - - - LTE Mobile Network Code of the Cell 1 Permanent I/O elements
25033 LTE Cell MNC 2 1 Unsigned - - - - LTE Mobile Network Code of the Cell 2 Permanent I/O elements
25034 LTE Cell MNC 3 1 Unsigned - - - - LTE Mobile Network Code of the Cell 3 Permanent I/O elements
25035 LTE Cell MNC 4 1 Unsigned - - - - LTE Mobile Network Code of the Cell 4 Permanent I/O elements
25019 LTE Signal RX 0 1 Unsigned 0 7 - - LTE Signal of the Cell 0 Permanent I/O elements
25022 LTE Signal RX 1 1 Unsigned 0 7 - - LTE Signal of the Cell 1 Permanent I/O elements
25025 LTE Signal RX 2 1 Unsigned 0 7 - - LTE Signal of the Cell 2 Permanent I/O elements
25028 LTE Signal RX 3 1 Unsigned 0 7 - - LTE Signal of the Cell 3 Permanent I/O elements
25031 LTE Signal RX 4 1 Unsigned 0 7 - - LTE Signal of the Cell 4 Permanent I/O elements
399 Time To First Fix 1 Unsigned 0 4294967295 - s Amount of time it took to get first GNSS fix Permanent I/O elements
20015 Modem Uptime 1 Unsigned 0 4294967295 - s Modem Uptime since the last wake up Permanent I/O elements
25015 Modem Uptime 8 Unsigned 0 4294967295 - s Modem Uptime since the last wake up (from FW X.4.10.Rev.00) Permanent I/O elements
20016 LTE RSRP 2 Signed -140 -44 - dBm Reference Signals Received Power Permanent I/O elements
20017 LTE RSRQ 1 Signed -3 -20 - dB Reference Signals Received Quality Permanent I/O elements
25016 LTE RSRP 2 Signed -140 -44 - dBm Reference Signals Received Power (from FW X.4.10.Rev.00) Permanent I/O elements
25017 LTE RSRQ 1 Signed -20 -3 - dB Reference Signals Received Quality (from FW X.4.10.Rev.00) Permanent I/O elements
449 Ignition On Counter value Unsigned 0 2147483647 - s Current value of the counter Permanent I/O elements
10800 EYE Temperature 1 2 Signed -32768 32767 0.01 °C Temperature measured by EYE Sensor 1 Permanent I/O elements
10801 EYE Temperature 2 2 Signed -32768 32767 0.01 °C Temperature measured by EYE Sensor 2 Permanent I/O elements
10802 EYE Temperature 3 2 Signed -32768 32767 0.01 °C Temperature measured by EYE Sensor 3 Permanent I/O elements
10803 EYE Temperature 4 2 Signed -32768 32767 0.01 °C Temperature measured by EYE Sensor 4 Permanent I/O elements
10804 EYE Humidity 1 1 Unsigned 0 100 - % Humidity measured by EYE Sensor 1 Permanent I/O elements
10805 EYE Humidity 2 1 Unsigned 0 100 - % Humidity measured by EYE Sensor 2 Permanent I/O elements
10806 EYE Humidity 3 1 Unsigned 0 100 - % Humidity measured by EYE Sensor 3 Permanent I/O elements
10807 EYE Humidity 4 1 Unsigned 0 100 - % Humidity measured by EYE Sensor 4 Permanent I/O elements
10808 EYE Magnet 1 1 Unsigned 0 1 - - Magnet measured by EYE Sensor by EYE Sensor 1 Permanent I/O elements
10809 EYE Magnet 2 1 Unsigned 0 1 - - Magnet measured by EYE Sensor by EYE Sensor 2 Permanent I/O elements
10810 EYE Magnet 3 1 Unsigned 0 1 - - Magnet measured by EYE Sensor by EYE Sensor 3 Permanent I/O elements
10811 EYE Magnet 4 1 Unsigned 0 1 - - Magnet measured by EYE Sensor by EYE Sensor 4 Permanent I/O elements
10812 EYE Movement 1 2 Unsigned 0 1 - - Movement state measure by EYE Sensor 1 Permanent I/O elements
10813 EYE Movement 2 2 Unsigned 0 1 - - Movement state measure by EYE Sensor 2 Permanent I/O elements
10814 EYE Movement 3 2 Unsigned 0 1 - - Movement state measure by EYE Sensor 3 Permanent I/O elements
10815 EYE Movement 4 2 Unsigned 0 1 - - Movement state measure by EYE Sensor 4 Permanent I/O elements
10816 EYE Pitch 1 1 Signed -90 90 - - Pitch angle measured by EYE Sensor 1 Permanent I/O elements
10817 EYE Pitch 2 1 Signed -90 90 - - Pitch angle measured by EYE Sensor 2 Permanent I/O elements
10818 EYE Pitch 3 1 Signed -90 90 - - Pitch angle measured by EYE Sensor 3 Permanent I/O elements
10819 EYE Pitch 4 1 Signed -90 90 - - Pitch angle measured by EYE Sensor 4 Permanent I/O elements
10820 EYE Low Battery 1 1 Unsigned 0 1 - - Low Battery indication for EYE Sensor 1 Permanent I/O elements
10821 EYE Low Battery 2 1 Unsigned 0 1 - - Low Battery indication for EYE Sensor 2 Permanent I/O elements
10822 EYE Low Battery 3 1 Unsigned 0 1 - - Low Battery indication for EYE Sensor 3 Permanent I/O elements
10823 EYE Low Battery 4 1 Unsigned 0 1 - - Low Battery indication for EYE Sensor 4 Permanent I/O elements
10824 EYE Battery Voltage 1 1 Unsigned 0 65535 - - Battery Voltage of EYE Sensor 1 Permanent I/O elements
10825 EYE Battery Voltage 2 1 Unsigned 0 65535 - - Battery Voltage of EYE Sensor 2 Permanent I/O elements
10826 EYE Battery Voltage 3 1 Unsigned 0 65535 - - Battery Voltage of EYE Sensor 3 Permanent I/O elements
10827 EYE Battery Voltage 4 1 Unsigned 0 65535 - - Battery Voltage of EYE Sensor 4 Permanent I/O elements
10832 EYE Roll 1 2 Signed -180 180 - - Roll angle measured by EYE Sensor 1 Permanent I/O elements
10833 EYE Roll 2 2 Signed -180 180 - - Roll angle measured by EYE Sensor 2 Permanent I/O elements
10834 EYE Roll 3 2 Signed -180 180 - - Roll angle measured by EYE Sensor 3 Permanent I/O elements
10835 EYE Roll 4 2 Signed -180 180 - - Roll angle measured by EYE Sensor 4 Permanent I/O elements
10836 EYE Movement count 1 2 Unsigned 0 65535 - - Movement count measure by EYE Sensor 1 Permanent I/O elements
10837 EYE Movement count 2 2 Unsigned 0 65535 - - Movement count measure by EYE Sensor 2 Permanent I/O elements
10838 EYE Movement count 3 2 Unsigned 0 65535 - - Movement count measure by EYE Sensor 3 Permanent I/O elements
10839 EYE Movement count 4 2 Unsigned 0 65535 - - Movement count measure by EYE Sensor 4 Permanent I/O elements
10840 EYE Magnet count 1 2 Unsigned 0 65535 - - Magnet trigger count measure by EYE Sensor 1 Permanent I/O elements
10841 EYE Magnet count 2 2 Unsigned 0 65535 - - Magnet trigger count measure by EYE Sensor 2 Permanent I/O elements
10842 EYE Magnet count 3 2 Unsigned 0 65535 - - Magnet trigger count measure by EYE Sensor 3 Permanent I/O elements
10843 EYE Magnet count 4 2 Unsigned 0 65535 - - Magnet trigger count measure by EYE Sensor 4 Permanent I/O elements
11317 EYE Sensor List variable length HEX 0 bytes 1024 bytes - - EYE Sensor List Permanent I/O elements

Eventual I/O elements

Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
155 Geofence zone 01 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
156 Geofence zone 02 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
157 Geofence zone 03 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
158 Geofence zone 04 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
159 Geofence zone 05 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
61 Geofence zone 06 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
62 Geofence zone 07 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
63 Geofence zone 08 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
64 Geofence zone 09 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
65 Geofence zone 10 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
70 Geofence zone 11 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
88 Geofence zone 12 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
91 Geofence zone 13 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
92 Geofence zone 14 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
93 Geofence zone 15 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
94 Geofence zone 16 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
95 Geofence zone 17 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
96 Geofence zone 18 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
97 Geofence zone 19 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
98 Geofence zone 20 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
99 Geofence zone 21 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
153 Geofence zone 22 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
154 Geofence zone 23 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
190 Geofence zone 24 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
191 Geofence zone 25 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
192 Geofence zone 26 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
193 Geofence zone 27 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
194 Geofence zone 28 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
195 Geofence zone 29 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
196 Geofence zone 30 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
197 Geofence zone 31 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
198 Geofence zone 32 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
208 Geofence zone 33 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
209 Geofence zone 34 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
216 Geofence zone 35 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
217 Geofence zone 36 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
218 Geofence zone 37 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
219 Geofence zone 38 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
220 Geofence zone 39 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
221 Geofence zone 40 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
222 Geofence zone 41 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
223 Geofence zone 42 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
224 Geofence zone 43 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
225 Geofence zone 44 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
226 Geofence zone 45 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
227 Geofence zone 46 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
228 Geofence zone 47 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
229 Geofence zone 48 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
230 Geofence zone 49 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements
231 Geofence zone 50 1 Unsigned 0 3 - -

0 – target left zone
1 – target entered zone
2 – over speeding end
3 – over speeding start

Eventual I/O elements -->
175 Auto Geofence 1 Unsigned 0 1 - -

0 – target left zone
1 – target entered zone

Eventual I/O elements
250 Trip 1 Unsigned 0 1 - - 0 – trip stop
1 – trip start
Eventual I/O elements
255 Overspeeding Event 1 Unsigned 0 255 - km/h

At over speeding start km/h, at over speeding end km/h

Eventual I/O elements
251 Idling 1 Unsigned 0 1 - -

0 – moving
1 – idling

Eventual I/O elements
252 Unplug 1 Unsigned 0 1 - -

0 – battery present
1 – battery unplug

Eventual I/O elements
253 Green driving type 1 Unsigned 1 3 - -

1 – harsh acceleration
2 – harsh braking
3 – harsh cornering

Eventual I/O elements
246 Towing 1 Unsigned 0 1 - -

0 – steady
1 – towing

Eventual I/O elements
247 Crash detection 1 Unsigned 1 5 - -

1 – crash
2 – limited crash trace (device not calibrated)
3 - limited crash trace (device is calibrated)
4 - full crash trace (device not calibrated)
5 - full crash trace (device is calibrated)
6 - crash detected (device not calibrated)

Eventual I/O elements
257 Crash trace data Variable HEX 0 1200 - - Crash trace data Eventual I/O elements
248 Immobilizer 1 Unsigned 0 2 - -

0 – iButton not connected
1 – iButton connected (Immobilizer)
2 – iButton connected (Authorized Driving)

Eventual I/O elements
254 Green Driving Value 1 Unsigned 0 1 0.01 G|rad Depending on green driving type: if harsh acceleration or braking – g*100 (value 123 -> 1.23g), if harsh cornering – degrees (value in radians) Eventual I/O elements
249 Jamming 1 Unsigned 0 1 - - 0 – jamming stop
1 – jamming start
Eventual I/O elements
243 Green driving event duration 2 Unsigned 0 65535 - ms Duration of event that did generate Green driving Eventual I/O elements
236 Alarm 1 Unsigned 0 1 - - 0 – Reserved
1 – Alarm event occurred
Eventual I/O elements
242 ManDown/FallDown 1 Unsigned 0 1 - - 0 – ManDown/FallDown deactivated
1 – ManDown/FalDown is active
Eventual I/O elements
310 Movement Event 1 Unsigned 0 1 - -

0 - Movement event occurred
1 - No Movement event occured

Eventual I/O elements
389 Button Click HEX Unsigned 0x11 0x53 - - Button ID (X) and Action (Y) Value 0xXY
X - button ID:
1 - alarm button
2 - power button
3 - button 1
4 - button 2
5 - button 3
Y - action:
1 - 1 click
2 - 2 clicks
3 - long click
Eventual I/O elements
390 Power Event 1 Unsigned 0 1 - - 1 - Device turned OFF
0 - Device turned ON

TMT250 GH5200

Eventual I/O elements
520 Tamper detection Event 1 Unsigned 0 1 - - 0 - Tamper restore
1 - Tamper alarm

TMT250

Eventual I/O elements
386 Last Known Position 2 Unsigned 0 65535 - s Time in seconds has passed since last GNSS fix
Eventual I/O elements
400 Amber Alert state 1 Unsigned 0 4 - -

0 - Turned Off
1 - Turned On, count down timer started
2 - Amber Alert On button pressed to restart active timer
3 - Alarm
4 - Amber Alert turned On when timer is set to 0 seconds

Eventual I/O elements
401 Amber Alert timer value 2 Unsigned 0 65535 - s

Sends Amber Alert time-out configured value

Eventual I/O elements


403 Heart Rate Alert 1 Unsigned 0 255 - BPM

Sends heart rate (BPM) from Xiaomi Mi Band 2

Eventual I/O elements
236 Alarm 1 Unsigned 0 1 - - 0 – Reserved
1 – Alarm event occurred
Eventual I/O elements
20012 Recovery mode alarm 1 Unsigned 0 2 - - 0 – Reserved
1 – Reserved
2 – Recovery alarm event occurred
Eventual I/O elements
20019 Tamper record event 2 Unsigned 0 3 - - 0 – Holder is removed
1 – Central is attached
2 – Attached to metal surface
3 – Removed from metal surface
Eventual I/O elements
20014 BLE Lost Beacon 1 Unsigned 0 3 - - 0 – Reserved
1 – Reserved
2 – Reserved
3 – BLE Lost Beacon
Eventual I/O elements
463 BLE1 EYE sensor lost alarm 2 HEX - - - - BEEF - BLE1 EYE sensor lost alarm Eventual I/O elements
467 BLE2 EYE sensor lost alarm 2 HEX - - - - BEEF - BLE2 EYE sensor lost alarm Eventual I/O elements
471 BLE3 EYE sensor lost alarm 2 HEX - - - - BEEF - BLE3 EYE sensor lost alarm Eventual I/O elements
475 BLE4 EYE sensor lost alarm 2 HEX - - - - BEEF - BLE4 EYE sensor lost alarm Eventual I/O elements

BLE Sensor I/O elements

Property ID in AVL packet Property Name Bytes Type Value range Multiplier Units Description HW Support Parameter Group
Min Max
25 BLE Temperature #1 2 Signed -400 12050 - °C Degrees ( °C ), -40 - +125;

Error codes:
32767 - sensor not found
32766 - failed sensor data parsing
32765 - abnormal sensor state

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
26 BLE Temperature #2 2 Signed -400 12050 - °C Degrees ( °C ), -40 - +125;

Error codes:
32767 - sensor not found
32766 - failed sensor data parsing
32765 - abnormal sensor state

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
27 BLE Temperature #3 2 Signed -400 12050 - °C Degrees ( °C ), -40 - +125;

Error codes:
32767 - sensor not found
32766 - failed sensor data parsing
32765 - abnormal sensor state

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
28 BLE Temperature #4 2 Signed -400 12050 - °C Degrees ( °C ), -40 - +125;

Error codes:
32767 - sensor not found
32766 - failed sensor data parsing
32765 - abnormal sensor state

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
29 BLE Battery #1 1 Unsigned 0 100 - % Battery level of sensor #1

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
20 BLE Battery #2 1 Unsigned 0 100 - % Battery level of sensor #2

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
22 BLE Battery #3 1 Unsigned 0 100 - % Battery level of sensor #3

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
23 BLE Battery #4 1 Unsigned 0 100 - % Battery level of sensor #4

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
86 BLE Humidity #1 2 Unsigned 0 1000 - %RH Humidity

Error codes:
32767 - sensor not found
32766 - failed sensor data parsing
32765 - abnormal sensor state

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
104 BLE Humidity #2 2 Unsigned 0 1000 - %RH Humidity

Error codes:
32767 - sensor not found
32766 - failed sensor data parsing
32765 - abnormal sensor state

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
106 BLE Humidity #3 2 Unsigned 0 1000 - %RH Humidity

Error codes:
32767 - sensor not found
32766 - failed sensor data parsing
32765 - abnormal sensor state

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
108 BLE Humidity #4 2 Unsigned 0 1000 - %RH Humidity

Error codes:
32767 - sensor not found
32766 - failed sensor data parsing
32765 - abnormal sensor state

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
331 BLE 1 Custom #1 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
463 BLE 1 Custom #2 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
464 BLE 1 Custom #3 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
465 BLE 1 Custom #4 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
466 BLE 1 Custom #5 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
332 BLE 2 Custom #1 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
467 BLE 2 Custom #2 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
468 BLE 2 Custom #3 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
469 BLE 2 Custom #4 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
470 BLE 2 Custom #5 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
333 BLE 3 Custom #1 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
471 BLE 3 Custom #2 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
472 BLE 3 Custom #3 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
473 BLE 3 Custom #4 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
474 BLE 3 Custom #5 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
334 BLE 4 Custom #1 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
475 BLE 4 Custom #2 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
476 BLE 4 Custom #3 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
477 BLE 4 Custom #4 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
478 BLE 4 Custom #5 256 HEX 0 4294967295 - - Custom IO element for BLE sensor

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
385 Beacon ID's - HEX - - - - Data structure:

Data part: 1 Byte
Beacon flag: 1 Byte
Beacon ID (iBeacon/Eddystone): 20 Bytes/16 Bytes
Signal strength: 1 Byte

TMT250 GH5200 TFT100 TST100

Bluetooth Low Energy
874 Bluetooth Home Zone Violation state 1 HEX - 0x0F - -

Bits describe the causes of violations:
0 - Back to Bluetooth Home Zone
1 - Movement (Only for Ela MOV sensor)
2 - RSSI threshold violation
4 - BLE missing

GH5200

Bluetooth Low Energy
889 Proximity Violation state 1 HEX - 0x0F - -

Bits describe the causes of violations:
1 - RSSI threshold violation
0 - End of RSSI violation

GH5200

Bluetooth Low Energy
875 Proximity violation source with Teltonika devices 12 ASCII - - - - MAC address which violates personal space

Example of encoded HEX ASCII text:
HEX: 44 35 41 34 31 42 38 42 31 30 37 35
HEX ASCII to text: D5A41B8B1075
(NOTE! From firmware version Rev.329 device sends IMEI instead of MAC address)
Example:
HEX -> ASCII (String)
3031343731353942383241454643 -> 0147159B82AEFC
HEX -> DEC
0147159B82AEFC -> 359633105628924

GH5200

Bluetooth Low Energy
876 Proximity violation source with iBeacons 32 ASCII - - - - Example of UUID encoded HEX to ASCII format:

HEX: 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 41 42 42 43 43 35 32 36 46 36 46 36 44 33 31
HEX to ASCII format: AAAAAAAAAAAAAAAAAABBCC526F6F6D31

GH5200

Bluetooth Low Energy
890 Proximity duration 2 Unsigned 0 65535 - s Violation time in seconds.
Included as an IO element with AVL ID 875

GH5200

Bluetooth Low Energy
891 BLE MAC address 12 ASCII - - - - BLE MAC address of device.

Example of encoded HEX ASCII text:
HEX: 44 35 41 34 31 42 38 42 31 30 37 35
HEX ASCII to text: D5A41B8B1075

GH5200

Bluetooth Low Energy
263 BT Status 1 Unsigned 0 4 - - 0 - BT is disabled
1 - BT Enabled, not device connected
2 - Device connected, BTv3 Only
3 - Device connected, BLE only
4 - Device connected, BLE + BT
Bluetooth Low Energy
871 BLE Lock Status 1 Unsigned 0 1 - - 0 – Unlocked
1 – Locked On
Bluetooth Low Energy
872 BLE Lock Battery 1 Unsigned 0 100 - % Battery level of Bluetooth lock Bluetooth Low Energy
873 BLE Lock Discovered 1 Unsigned 0 1 - 1 - Bluetooth lock Discovered Bluetooth Low Energy
585 BLE Devices - HEX - - - - Data structure:

Number of beacons: 1 Byte
MAC Adress: 6 Bytes
RSSI: 1 Byte
Slot: 1 Byte
Main size: 1 Byte
Main Data: 0-32 Bytes
Additional Data size: 1 Byte
Additional Data: 0-32 Bytes

TMT250 GH5200