Line 1: |
Line 1: |
| ==Introduction to Smart Ignition Detection functionality== | | ==Introduction to Smart Ignition Detection functionality== |
| + | |
| Smart Ignition detection is a functionality which detects ignition by sudden external voltage jumps instead of manually predefined High and Low voltage thresholds. | | Smart Ignition detection is a functionality which detects ignition by sudden external voltage jumps instead of manually predefined High and Low voltage thresholds. |
| | | |
Line 25: |
Line 26: |
| | | |
| • Smart Ignition Duration (s) – Time interval used for comparing current external voltage against historical external voltage configured seconds ago. | | • Smart Ignition Duration (s) – Time interval used for comparing current external voltage against historical external voltage configured seconds ago. |
| + | |
| + | |
| + | |
| + | |
| + | |
| + | |
| + | |
| + | |
| + | |
| + | |
| + | {| class="wikitable" |
| + | |+ |
| + | ! rowspan="2" style="width: 150px; background: #003475; color: white;" |'''Parameter ID''' |
| + | ! rowspan="2" style="width: 150px; background: #003475; color: white;" |'''Name''' |
| + | ! colspan="3" style="width: 150px; background: #003475; color: white;" |'''Value range''' |
| + | ! rowspan="2" style="width: 250px; background: #003475; color: white;" |'''Description''' |
| + | |- |
| + | ! style="width: 75px; background: #003475; color: white;" |Min |
| + | ! style="width: 75px; background: #003475; color: white;" |Max |
| + | ! style="width: 75px; background: #003475; color: white;" |Default |
| + | |- |
| + | !style="text-align: center; vertical-align: center;" |66201 |
| + | |style="text-align: center; vertical-align: center;" |Smart Ignition |
| + | |style="text-align: center; vertical-align: center;" |0 |
| + | |style="text-align: center; vertical-align: center;" |1 |
| + | |style="text-align: center; vertical-align: center;" |1 |
| + | |style="text-align: center;" |0 - Disabled; <br> 1 - Enabled |
| + | |- |
| + | !style="text-align: center; vertical-align: center;" |66202 |
| + | |style="text-align: center; vertical-align: center;" |Smart Ignition Delta, mV |
| + | |style="text-align: center; vertical-align: center;" |100 |
| + | |style="text-align: center; vertical-align: center;" |2000 |
| + | |style="text-align: center; vertical-align: center;" |600 |
| + | |style="text-align: center;" |How much external voltage must change, in miliVolts to detect ignition ON or OFF event. |
| + | |- |
| + | !style="text-align: center; vertical-align: center;" |66203 |
| + | |style="text-align: center; vertical-align: center;" |Smart Ignition Duration, s |
| + | |style="text-align: center; vertical-align: center;" |2 |
| + | |style="text-align: center; vertical-align: center;" |20 |
| + | |style="text-align: center; vertical-align: center;" |3 |
| + | |style="text-align: center;" |Time interval, in seconds, used for comparing current external voltage against historical external voltage configured seconds ago. |
| + | |- |