421 bytes added
, 10:19, 4 June 2018
Command sets SMS warning on I/O#1 element.
SMS Format:
*setparam X Y,W,Z
*X – ID
*Y – Enable/Disable (1/0)
*W – Telephone number INDEX (SMS Event Predefined Numbers paragraph, ID 150 – INDEX 0; ID151 – INDEX 1, …)
*Z – SMS Text
**Example: ''setparam 5100 1,5,Digital Input 1 Event!''
Other I/O element SMS events can be configured in same logic. All I/O element SMS event IDs are listed in the next table.