Changes

no edit summary
Line 6: Line 6:  
*Records Settings, where user can enable or disable records when GPS is not available (no time synchronization);
 
*Records Settings, where user can enable or disable records when GPS is not available (no time synchronization);
 
*GNSS Settings, where user can choose satellite system and GNSS FIX Timeout Time (if after timeout there will not be synchronized time, it will be synchronized via NTP server);
 
*GNSS Settings, where user can choose satellite system and GNSS FIX Timeout Time (if after timeout there will not be synchronized time, it will be synchronized via NTP server);
*Ignition Source sets ignition triggered functionalities to be triggered by:
+
*Ignition Settings:
 +
Ignition Source - sets ignition triggered functionalities to be triggered by:
 
**Power Voltage (if voltage is between High Voltage Level and Low Voltage Level the ignition is considered to be turned on);
 
**Power Voltage (if voltage is between High Voltage Level and Low Voltage Level the ignition is considered to be turned on);
 
**Digital Input (DIN1 ON – ignition on, DIN1 OFF – ignition off);
 
**Digital Input (DIN1 ON – ignition on, DIN1 OFF – ignition off);
 
**Movement (if accelerometer/movement sensor detects movement then ignition is on, if movement stops – ignition is off).
 
**Movement (if accelerometer/movement sensor detects movement then ignition is on, if movement stops – ignition is off).
 +
Ignition Detection:
 +
**Manual – user manually selects Power Voltage range;
 +
**Automatic – automatically detect Power Voltage change.
 +
      Line 37: Line 42:       −
{{{foto|[[Image:FMA2_Configurator_system.jpg|650px]]}}}
+
{{{foto|[[Image:FMA2_Configurator_system.png|650px]]}}}
       
Also if Power Voltage is chosen for ignition source there is possibility to choose Manual ignition detection or automatic ignition detection. For manual ignition user has to choose power voltage levels by himself. For  
 
Also if Power Voltage is chosen for ignition source there is possibility to choose Manual ignition detection or automatic ignition detection. For manual ignition user has to choose power voltage levels by himself. For  
 
automatic ignition {{{model|FM36YX}}} automatically detects ignition. In 12 V systems ignition is on when voltage is between 13,2 – 16 V and for 24 V systems ignition is detected when voltage is between 27 – 32 V.
 
automatic ignition {{{model|FM36YX}}} automatically detects ignition. In 12 V systems ignition is on when voltage is between 13,2 – 16 V and for 24 V systems ignition is detected when voltage is between 27 – 32 V.