Line 78: |
Line 78: |
| In order to use LLS fuel counter the newest firmware version is needed which can be obtained from Teltonika or a representative. Firmware is updated over GPRS or using cable update method. <br> | | In order to use LLS fuel counter the newest firmware version is needed which can be obtained from Teltonika or a representative. Firmware is updated over GPRS or using cable update method. <br> |
| The LLS fuel sensor must be connected to the FMB640 device. <br> | | The LLS fuel sensor must be connected to the FMB640 device. <br> |
| + | |
| + | ===Specifications=== |
| + | |
| + | {| class="wikitable" |
| + | |+ |
| + | ! style="width: 200px; background: black; color: white;" | Parameter |
| + | ! style="width: 300px; background: black; color: white;" | Value |
| + | |- |
| + | ! style="text-align: center; vertical-align: top;" | Supply voltage |
| + | | style="text-align: center; vertical-align: top;" | +10..+50 V |
| + | |- |
| + | ! style="text-align: center; vertical-align: top;" | Current consumption, mA (for 12/24 V) |
| + | | style="text-align: center; vertical-align: top;" | 25 mA / 50 mA. |
| + | |- |
| + | ! style="text-align: center; vertical-align: top;" | Working temperature |
| + | | style="text-align: center; vertical-align: top;" | -40..+85 ºC |
| + | |- |
| + | ! style="text-align: center; vertical-align: top;" | Working mode |
| + | | style="text-align: center; vertical-align: top;" | continuous |
| + | |- |
| + | ! style="text-align: center; vertical-align: top;" | Weight |
| + | | style="text-align: center; vertical-align: top;" | < 2.0 Kg. |
| + | |- |
| + | ! style="text-align: center; vertical-align: top;" | Working pressure |
| + | | style="text-align: center; vertical-align: top;" | atmospheric |
| + | |- |
| + | |} |
| + | |
| [[image:FMB640_RS232_LLS.png]] | | [[image:FMB640_RS232_LLS.png]] |
| | | |