Trip settings:
 
Trip settings:
 
*<span style="background-color:#91b9d4;">11800</span> - Scenario priority (0 - Disable, 1 - Low, 2 - High, 3 - Panic).
 
*<span style="background-color:#91b9d4;">11800</span> - Scenario priority (0 - Disable, 1 - Low, 2 - High, 3 - Panic).
<br>
+
 
 
*<span style="background-color:#91d4b9;">11801</span> - Eventual settings (0 - Disable, 1 - Enable), if disabled - trip settings will come with periodical data.
 
*<span style="background-color:#91d4b9;">11801</span> - Eventual settings (0 - Disable, 1 - Enable), if disabled - trip settings will come with periodical data.
<br>
+
 
 
* 11802 - Mode (0 - Continuous, 1 Between Records). If Between Records option is selected distance will be counted until any record is made. Then odometer will be reset to zero and start counting until next record is made. When it is set to Continuous, Trip distance is going to be counted continuously (from Trip start to Trip end) and written to I/O Trip Odometer value field. When Trip is over and the next Trip begins, Trip Odometer value is reset to zero.
 
* 11802 - Mode (0 - Continuous, 1 Between Records). If Between Records option is selected distance will be counted until any record is made. Then odometer will be reset to zero and start counting until next record is made. When it is set to Continuous, Trip distance is going to be counted continuously (from Trip start to Trip end) and written to I/O Trip Odometer value field. When Trip is over and the next Trip begins, Trip Odometer value is reset to zero.
 
* 11803 - Start Speed (km/h). If start speed selected 0 the trip only will work then ignition is on.
 
* 11803 - Start Speed (km/h). If start speed selected 0 the trip only will work then ignition is on.
Line 57: Line 57:     
Ignition Source:
 
Ignition Source:
 +
 +
    
* <span style="background-color:#91b9d3;">101</span> - Eventual settings (1 - DIN 1, 2 - Accelerometer,  4 - Power Voltage, 8 - Engine RPM).
 
* <span style="background-color:#91b9d3;">101</span> - Eventual settings (1 - DIN 1, 2 - Accelerometer,  4 - Power Voltage, 8 - Engine RPM).
Line 76: Line 78:  
In the photo below (this is example case) you see where you must go to configurate main parameter that you need to have from device.
 
In the photo below (this is example case) you see where you must go to configurate main parameter that you need to have from device.
   −
In OBD II window you see a lot of I/O elements to configure the device properly you will need to know which parameters can be read from the vehicle using our OBD trackers. To know what parameters can be read please visit [https://wiki.teltonika-gps.com/view/How_to_check_available_OBDII_data%3F How to check available OBDII data].
+
In OBD II window you see a lot of I/O elements to configure the device properly you will need to know which parameters can be read from the vehicle using our OBD trackers. To know what parameters can be read please visit  
    
[[File:Obd_turbo.jpg|alt=|frameless|825x825px]]
 
[[File:Obd_turbo.jpg|alt=|frameless|825x825px]]