! Level || Protection against || Effective against || Details
! Level || Protection against || Effective against || Details
|-
|-
−
! 0 || None || — || —
+
! 0
+
| None || — || —
|-
|-
−
! 1 || Dripping water || Dripping water (vertically falling drops) shall have no harmful effect on the specimen when mounted in an upright position onto a turntable and rotated at 1 RPM. || Test duration: 10 minutes <br />
+
! 1
+
| Dripping water || Dripping water (vertically falling drops) shall have no harmful effect on the specimen when mounted in an upright position onto a turntable and rotated at 1 RPM. || Test duration: 10 minutes <br />
Water equivalent to 1 mm rainfall per minute<br />
Water equivalent to 1 mm rainfall per minute<br />
|-
|-
−
! 2 || Dripping water when tilted at 15° || Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle of 15° from its normal position. A total of four positions are tested within two axes. || 2.5 minutes for every direction of tilt (10 minutes total) <br />
+
! 2
+
| Dripping water when tilted at 15° || Vertically dripping water shall have no harmful effect when the enclosure is tilted at an angle of 15° from its normal position. A total of four positions are tested within two axes. || 2.5 minutes for every direction of tilt (10 minutes total) <br />
Water equivalent to 3 mm rainfall per minute<br />
Water equivalent to 3 mm rainfall per minute<br />