==LLS Sensor==
  −
LLS sensor series liquid level sensors are solid-state capacitive devices with no moving parts. The sensors use capacitive technology to produce accurate liquid level measurements of standard factory-grade DIESEL OIL and PURE GASOLINE (BENZINE) carbon fuels. The LLS sensor liquid level sensors are strictly prohibited to use in any liquids which are not factory-grade carbon fuels or contain: BIOFUEL, METHANOL, ETHANOL, UREA, and similar aggressive components in pure form or as additives for factory-grade carbon fuels for use in INTERNAL COMBUSTION ENGINES. Operating media – Diesel fuel (oil), pure gasoline (benzene). <br>
  −
In order to use the LLS fuel counter, the newest firmware version is needed which can be obtained from Teltonika or a representative. Firmware is updated over GPRS or using a cable update method. <br>
  −
  −
===Specifications===
  −
--------------------
  −
<table class="nd-othertables_2" style="width:40%;">
  −
<tr>
  −
        <th rowspan="1" style="width:70%; vertical-align: middle; text-align: center;">Parameter</th>
  −
        <th rowspan="1" style="width:30%; vertical-align: middle; text-align: center;">Value</th>
  −
    </tr>
  −
<tr>
  −
        <th style="border-bottom: 1px solid #E8E8E8; vertical-align: middle; text-align: left; color:black">Supply voltage</th>
  −
        <td style="vertical-align: middle; text-align: left; ">+10..+50 V</td>
  −
    </tr>
  −
<tr>
  −
        <th style="border-bottom: 1px solid #E8E8E8; vertical-align: middle; text-align: left; color:black">Current consumption, mA (for 12/24 V)</th>
  −
        <td style="vertical-align: middle; text-align: left; ">25 mA / 50 mA</td>
  −
    </tr>
  −
<tr>
  −
        <th style="border-bottom: 1px solid #E8E8E8; vertical-align: middle; text-align: left; color:black">Working temperature</th>
  −
        <td style="vertical-align: middle; text-align: left; ">-40..+85 ºC</td>
  −
    </tr>
  −
<tr>
  −
        <th style="border-bottom: 1px solid #E8E8E8; vertical-align: middle; text-align: left; color:black">Working mode</th>
  −
        <td style="vertical-align: middle; text-align: left; ">Continuous</td>
  −
    </tr>
  −
<tr>
  −
        <th style="border-bottom: 1px solid #E8E8E8; vertical-align: middle; text-align: left; color:black">Weight</th>
  −
        <td style="vertical-align: middle; text-align: left; ">< 2.0 kg</td>
  −
    </tr>
  −
<tr>
  −
        <th style="border-bottom: 1px solid #E8E8E8; vertical-align: middle; text-align: left; color:black">Working pressure</th>
  −
        <td style="vertical-align: middle; text-align: left; ">Atmospheric</td>
  −
    </tr>
  −
</table>
  −
  −
===Wiring And Configuration===
  −
------------------------------
  −
First of all, the LLS fuel sensor must be connected to the [[{{{model|FMB125}}}]] device. Please find examples below:
  −
<table class="nd-othertables_2" style="width:100%;">
  −
<tr>
  −
        <td style="vertical-align: middle; text-align: left; ">'''Using RS232 socket'''</td>
  −
        <td style="vertical-align: middle; text-align: left; ">'''Using RS485 socket'''</td>
  −
    </tr>
  −
<tr>
  −
        <td style="vertical-align: middle; text-align: left; ">[[Image:FMX125_LLS_RS232-wiring scheme.png|580px]]</td>
  −
        <td style="vertical-align: middle; text-align: left; ">[[Image:FMX125_LLS_RS485-wiring scheme.png|580px]]</td>
  −
    </tr>
  −
<tr>
  −
</table>
  −
  −
Then [[{{{model|FMB125}}}]] must be configured. Both fuel level and fuel temperature has to be set up by the configurator’s I/O menu: <br>
  −