Changes

no edit summary
Line 41: Line 41:  
         <tr>
 
         <tr>
 
         <td style="vertical-align:middle; width: 40%">2 W max.<br>Current consumption at 12 V (Power supply 6...30 V DC) </td>
 
         <td style="vertical-align:middle; width: 40%">2 W max.<br>Current consumption at 12 V (Power supply 6...30 V DC) </td>
         <td style="vertical-align:middle; width: 30%"> GPRS: average 64.59 mA rms<br>Nominal: average 37.77 rms<br>GNSS sleep: average 11.1 mA<br>Deep Sleep: average 6.2 mA<br>Online Deep Sleep: average 6.5 mA<br>
+
         <td style="vertical-align:middle; width: 30%">
 +
* At 12V < 3 mA (Ultra Deep Sleep)
 +
* At 12V < 5 mA (Deep Sleep)
 +
* At 12V < 11 mA (Online Deep Sleep)
 +
* At 12V < 18 mA (GPS Sleep)
 +
* At 12V < 34 mA (nominal with no load)
 +
* At 12V < 2A Max. (with full Load / Peak) </td>
 +
<br>
 
     </tr>
 
     </tr>
 
         <tr>
 
         <tr>
Line 49: Line 56:  
         <tr>
 
         <tr>
 
         <td style="vertical-align:middle">Operating temperature (without battery)</td>
 
         <td style="vertical-align:middle">Operating temperature (without battery)</td>
         <td style="vertical-align:middle">-40..+85 °C</td>
+
         <td style="vertical-align:middle">-20..+85 °C</td>
 
     </tr>
 
     </tr>
 
         <tr>
 
         <tr>
 
         <td style="vertical-align:middle">Storage temperature (without battery)</td>
 
         <td style="vertical-align:middle">Storage temperature (without battery)</td>
         <td style="vertical-align:middle">-40..+85 °C</td>
+
         <td style="vertical-align:middle">-20..+85 °C</td>
 
     </tr>
 
     </tr>
 
         <tr>
 
         <tr>
         <td style="vertical-align:middle">Storage relative humidity</td>
+
        <td style="vertical-align:middle">Operating temperature (with battery)</td>
         <td>5..95% (no condensation)</td>
+
        <td style="vertical-align:middle">-20..+40 °C</td>
 +
</tr>
 +
         <tr>
 +
        <td style="vertical-align:middle">Storage temperature (with battery)</td>
 +
         <td style="vertical-align:middle">5..95% (no condensation) </td>
 +
</tr>
 +
        <tr>
 +
        <td style="vertical-align:middle">Operating humidity</td>
 +
        <td style="vertical-align:middle">0..+45 °C</td>
 +
    </tr>
 +
        <tr>
 +
        <td style="vertical-align:middle">Ingress Protection Rating</td>
 +
        <td>IP41</td>
 +
</tr>
 +
        <tr>
 +
        <td style="vertical-align:middle">Battery charge temperature</td>
 +
        <td>0..+45 °C</td>
 +
</tr>
 +
        <tr>
 +
        <td style="vertical-align:middle">Battery discharge temperature</td>
 +
        <td>-20..+60 °C</td>
 
     </tr>
 
     </tr>
 
         <tr>
 
         <tr>