Line 11: |
Line 11: |
| The first digit indicates the level of protection that the enclosure provides against access to hazardous parts (e.g., electrical conductors, moving parts) and the ingress of solid foreign objects. | | The first digit indicates the level of protection that the enclosure provides against access to hazardous parts (e.g., electrical conductors, moving parts) and the ingress of solid foreign objects. |
| | | |
− | {| class="wikitable" border=1 | + | {| class="wikitable" |
− | ! Level sized || Effective against || Description | + | |+ |
| + | ! rowspan="1" style="width: 73px; background: #0054A6; color: white;" |'''Level sized''' |
| + | ! rowspan="1" style="width: 109px; background: #0054A6; color: white;" |'''Effective against''' |
| + | ! rowspan="1" style="width: 1000px; background: #0054A6; color: white;" |'''Description''' |
| |- | | |- |
− | ! 0
| + | | rowspan="1" style="text-align: center; style=" width: 150px; background: white; color: black;" |0 |
− | | — || No protection against contact and ingress of objects. | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |— |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |No protection against contact and ingress of objects. |
| |- | | |- |
− | ! 1
| + | | rowspan="1" style="text-align: center; style=" width: 150px; background: white; color: black;" |1 |
− | | >50 mm || Any large surface of the body, such as the back of a hand, but no protection against deliberate contact with a body part. | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |>50 mm |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Any large surface of the body, such as the back of a hand, but no protection against deliberate contact with a body part. |
| |- | | |- |
− | ! 2
| + | | rowspan="1" style="text-align: center; style=" width: 150px; background: white; color: black;" |2 |
− | | >12.5 mm || Fingers or similar objects. | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |>12.5 mm |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Fingers or similar objects. |
| |- | | |- |
− | ! 3
| + | | rowspan="1" style="text-align: center; style=" width: 150px; background: white; color: black;" |3 |
− | | >2.5 mm || Tools, thick wires, etc. | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |>2.5 mm |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Tools, thick wires, etc. |
| |- | | |- |
− | ! 4
| + | | rowspan="1" style="text-align: center; style=" width: 150px; background: white; color: black;" |4 |
− | | >1 mm || Most wires, slender screws, large ants etc. | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |>1 mm |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Most wires, slender screws, large ants etc. |
| |- | | |- |
− | ! 5
| + | | rowspan="1" style="text-align: center; style=" width: 150px; background: white; color: black;" |5 |
− | | Dust protected || Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment. | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Dust protected |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Ingress of dust is not entirely prevented, but it must not enter in sufficient quantity to interfere with the satisfactory operation of the equipment. |
| |- | | |- |
− | ! 6
| + | | rowspan="1" style="text-align: center; style=" width: 150px; background: white; color: black;" |6 |
− | | Dust tight || No ingress of dust; complete protection against contact (dust tight). A vacuum must be applied. Test duration of up to 8 hours based on air flow. | + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |Dust tight |
| + | | rowspan="1" style="text-align: left; style=" width: 150px; background: white; color: black;" |No ingress of dust; complete protection against contact (dust tight). A vacuum must be applied. Test duration of up to 8 hours based on air flow. |
| |} | | |} |
| | | |