In order to properly connect the Iridium device to {{{device|}}}, Iridium has to be connected to the device via RS-232 - COM1 or COM2 (paminėt kur TX/RX jungt ir pridėt screenshot COM pinų). Additionally '''Pin No. 6''' - power control (reference in the image below) must be connected to one of the {{{device|}}} DOUTs (1/2/3/4), in order to allow the device to power ON/OFF Iridium device on demand.
+
In order to properly connect the Iridium device to {{{device|}}}, Iridium has to be connected to the device via RS-232 - COM1 or COM2 (with RJ-45 connector, where 4 pin is GND, 5 pin is RS232 Rx and 6 PIN is RS232 Tx). Additionally '''Pin No. 6''' - power control (reference in the image below) must be connected to one of the {{{device|}}} DOUTs (1/2/3/4), in order to allow the device to power ON/OFF Iridium device on demand.
   −