Changes

no edit summary
Line 2: Line 2:  
| product_name  = FMB130 tracking device
 
| product_name  = FMB130 tracking device
 
}}
 
}}
 +
 +
==2022.11.01: Base firmware update==
 +
We would like to inform you about the base firmware update for FMB130 starting from August 1st, 2022. New production firmware version will be 03.27.13.Rev.03
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change description
 +
|-
 +
| style="text-align: left; background: white;" |Change type
 +
| colspan="2" style="text-align: left; background: white;" |PCB Design Change and Firmware update
 +
|-
 +
| rowspan="2" style="width: 221px; text-align: left; background: white;" |Detailed description
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |Key improvements from last production firmware are listed in errata: https://wiki.teltonika-gps.com/view/FMB130_firmware_errata
 +
|-
 +
| style="text-align: left; background: white;" |Old version: <br> FMB130 03.27.13.Rev.03
 +
| style="text-align: left; background: white;" |New version: <br> FMB130 03.27.14.Rev.00
 +
|-
 +
| style="text-align: left; background: white;" |Change reasons
 +
| colspan="2" style="text-align: left; background: white;" |PCB design optimization due to prevent the shortage of 1-wire components and ensure stable supply.
 +
Together with PCB design update new firmware released to support changes in updated hardware.
 +
|-
 +
| style="text-align: left; background: white;" | Product release date
 +
| colspan="2" style="text-align: left; background: white;" |2022-November – Firmware Update <br>2023-January – PCB design Changes</br>
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Affected products
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Model
 +
| style="width: 448px; text-align: left; background: white;" |Affected order codes
 +
| style="width: 448px; text-align: left; background: white;" | Order code changes
 +
|-
 +
| style="text-align: left; background: white;" |FMB130
 +
| style="text-align: left; background: white;" |FMB130******* order codes with base Firmware
 +
| style="text-align: left; background: white;" |Update firmware
 +
|-
 +
|}
 +
 +
{| class="wikitable"
 +
|+
 +
! colspan="3" style="text-align: left; background: white;" |Change impact
 +
|-
 +
| style="width: 221px; text-align: left; background: white;" |Risk assessment
 +
| colspan="2" style="width: 908px; text-align: left; background: white;" |1. Clients with special firmware versions or order codes with special firmware will have to update firmware manually.
 +
2. Using old firmware version on updated PCB will cause of 1-wire malfunction.
 +
|-
 +
| style="text-align: left; background: white;" |Suggested implementation plan
 +
| colspan="2" style="text-align: left; background: white;" | 1. We highly recommend updating the spec.firmware`s with the latest version in order to support new changes on FMB130 hardware.
 +
2. For further assistance, including the updates of special firmware versions, please contact your Teltonika Telematics sales manager or fill query on VIP HelpDesk.
 +
|-
 +
|}
 +
    
==2022.08.01: Base firmware update==
 
==2022.08.01: Base firmware update==