Line 2: |
Line 2: |
| | product_name = FMC640 tracking device | | | product_name = FMC640 tracking device |
| }} | | }} |
| + | |
| + | ==2023.10.06: COM ports changes== |
| + | |
| + | We would like to inform you, that FMC640 device COM port component will be updated in the factory by the end of October 2023. |
| + | |
| + | {| class="wikitable" style="width:100%;" |
| + | |+ |
| + | ! colspan="3" style="text-align: left; background: white;" |Change description |
| + | |- |
| + | | style="text-align: left; background: white;" |Change type |
| + | | colspan="2" style="text-align: left; background: white;" |External/visual |
| + | |- |
| + | | rowspan="2" style="width: 20%; text-align: left; background: white;" |Detailed description |
| + | |
| + | |
| + | |- |
| + | | style="width: 40%; text-align: left; background: white;" |Old version: [[File:Old jungtys.png|center|400 x 400px]] |
| + | | style="width: 40%; text-align: left; background: white;" |New version: [[File:New jungtys.png|center|400 x 400px]] |
| + | |- |
| + | | style="text-align: left; background: white;" |Description |
| + | | colspan="2" style="text-align: left; background: white;" |Changes are made only in internal part of PCB for COM1 and COM2 ports sockets. This socket is 1 mm longer than the older one and in this case there could be visible changes from external side |
| + | |- |
| + | | style="text-align: left; background: white;" |Change reasons |
| + | | colspan="2" style="text-align: left; background: white;" |Reaction to components for COM port market volatility. |
| + | |
| + | |- |
| + | |- |
| + | | style="text-align: left; background: white;" |Product release date |
| + | | colspan="2" style="text-align: left; background: white;" |End of October 2023 |
| + | |- |
| + | |} |
| + | |
| + | {| class="wikitable" style="width:100%;" |
| + | |+ |
| + | ! colspan="3" style="text-align: left; background: white;" |Affected products |
| + | |- |
| + | | style="width: 20%; text-align: left; background: white;" |Model |
| + | | style="width: 40%; text-align: left; background: white;" |Affected order codes |
| + | | style="width: 40%; text-align: left; background: white;" |Order code changes |
| + | |- |
| + | | style="text-align: left; background: white;" |FMC640 |
| + | | style="text-align: left; background: white;" |FMC640******* |
| + | | style="text-align: left; background: white;" |No Changes |
| + | |- |
| + | |} |
| + | |
| + | {| class="wikitable" style="width:100%;" |
| + | |+ |
| + | ! colspan="3" style="text-align: left; background: white;" |Change impact |
| + | |- |
| + | | style="width: 20%; text-align: left; background: white;" |Risk assessment |
| + | | colspan="2" style="width: 80%; text-align: left; background: white;" |Due to new COM port housing device COM ports are protruding by 1 mm. Functionality remains unchanged. |
| + | [[File:Jungtys 2.png|center|400 x 400px]] |
| + | |- |
| + | | style="text-align: left; background: white;" |Suggested implementation plan |
| + | | colspan="2" style="text-align: left; background: white;" |No implementation plan needed |
| + | |- |
| + | |} |
| + | |
| + | {| class="wikitable" style="width:100%;" |
| + | |+ |
| + | ! colspan="3" style="width: 100%; text-align: left; background: white;" |Acknowledgement of PCN receipt |
| + | |- |
| + | | colspan="3" style="text-align: left; background: white;" |If no feedback is received within two weeks after the issue date of this notification - Teltonika may accept that this change has been tacitly accepted and can implement the change as indicated above |
| + | |- |
| + | |} |
| + | |
| | | |
| ==2023.07.12: FMC640 END OF LIFE Announcement== | | ==2023.07.12: FMC640 END OF LIFE Announcement== |