==Green Driving==
 
==Green Driving==
   −
[[Image:Fmb120_green_driving.png|300px|right]]
+
{{{pic_greendriving|[[Image:Fmb120_green_driving.png|300px|right]]}}}
    
When vehicle exceeds the values of ''Max Acceleration'', ''Max Braking'' or ''Max Cornering'' parameters, the scenario is activated: a record is generated and digital output status is changed to 1 (when configured). You can configure all three parameters in m/s<sup>2</sup> (meter per second squared) units. Scenario is activated until current Acceleration, Braking or Cornering value decreases below the set parameter value.<br/>Parameters used with ''Green Driving'' functionality are given in a table below.
 
When vehicle exceeds the values of ''Max Acceleration'', ''Max Braking'' or ''Max Cornering'' parameters, the scenario is activated: a record is generated and digital output status is changed to 1 (when configured). You can configure all three parameters in m/s<sup>2</sup> (meter per second squared) units. Scenario is activated until current Acceleration, Braking or Cornering value decreases below the set parameter value.<br/>Parameters used with ''Green Driving'' functionality are given in a table below.
Line 49: Line 49:  
==Over Speeding==
 
==Over Speeding==
   −
[[Image:Fmb120 over speeding.png|300px|right]]
+
{{{pic_overspeeding|[[Image:Fmb120 over speeding.png|300px|right]]}}}
    
When vehicle speed exceeds configured maximum speed value the scenario is activated:a record is generated and digital output status is changed to 1 (if configured).<br/>Scenario is active until current speed decreases below the set parameter value.
 
When vehicle speed exceeds configured maximum speed value the scenario is activated:a record is generated and digital output status is changed to 1 (if configured).<br/>Scenario is active until current speed decreases below the set parameter value.
Line 56: Line 56:  
==Jamming==
 
==Jamming==
   −
[[Image:Fmb120_jamming.png|300px|right]]
+
{{{pic_jamming|[[Image:Fmb120_jamming.png|300px|right]]}}}
    
When jamming is detected the  scenario is activated: a record is generated and digital output status is changed to 1 (if configured).<br/>Jamming timeout time can be configured. Digital output control and jamming event will be generated once ''Jamming'' timeout runs out. If jamming ends during timeout countdown no event will be generated and output will not be controlled.<br/>''Eventual Records'' parameter can be configured - when it is disabled scenario status value will appear in each AVL record, otherwise it will be appended only to eventual records.
 
When jamming is detected the  scenario is activated: a record is generated and digital output status is changed to 1 (if configured).<br/>Jamming timeout time can be configured. Digital output control and jamming event will be generated once ''Jamming'' timeout runs out. If jamming ends during timeout countdown no event will be generated and output will not be controlled.<br/>''Eventual Records'' parameter can be configured - when it is disabled scenario status value will appear in each AVL record, otherwise it will be appended only to eventual records.
Line 63: Line 63:  
== DOUT Control Via Call==
 
== DOUT Control Via Call==
   −
[[Image:Fmb120_dout_via_call.png|300px|right]]
+
{{{pic_dout_control|[[Image:Fmb120_dout_via_call.png|300px|right]]}}}
    
Scenario is activated and digital output is ON, when call is received from a number which is on the authorized numbers list.<br/>
 
Scenario is activated and digital output is ON, when call is received from a number which is on the authorized numbers list.<br/>
 
Call control functionality:
 
Call control functionality:
* When {{{model|FMB1YX}}} is configured to control DOUT1/DOUT2 the device waits for an incoming call from a configured secure number. If the call is received {{{model|FMB1YX}}} turns on DOUT1/DOUT2 for user defined ''Duration Timeout''. If duration timeout set to "0", DOUT1/DOUT2 will be OFF.
+
* When {{{model|FMB1YX}}} is configured to control {{{text_dout|DOUT1/DOUT2}}} the device waits for an incoming call from a configured secure number. If the call is received {{{model|FMB1YX}}} turns on {{{text_dout|DOUT1/DOUT2}}} for user defined ''Duration Timeout''. If duration timeout set to "0", {{{text_dout|DOUT1/DOUT2}}} will be OFF.
* DOUT1/DOUT2 can be turned off by ''Duration Timeout'' or by digital input 1, digital input 2 or digital input 3.
+
* {{{text_dout|DOUT1/DOUT2}}} can be turned off by ''Duration Timeout'' or by digital input 1, digital input 2 or digital input 3.
* DOUT1/DOUT2 can be turned off before ''Duration Timeout'' by a selected digital input.
+
* {{{text_dout|DOUT1/DOUT2}}} can be turned off before ''Duration Timeout'' by a selected digital input.
* DOUT1/DOUT2 will always be ON, if, for example, DOUT deactivation is set to DIN1, but DIN1 will be never turned ON, or when duration timeout is set to maximum value (2147483647), which is about 68 years.
+
* {{{text_dout|DOUT1/DOUT2}}} will always be ON, if, for example, DOUT deactivation is set to DIN1, but DIN1 will be never turned ON, or when duration timeout is set to maximum value (2147483647), which is about 68 years.
    
==Immobilizer==
 
==Immobilizer==
   −
[[Image:Fmb120_immobilizer.png|300px|right]]
+
{{{pic_immobilizer|[[Image:Fmb120_immobilizer.png|300px|right]]}}}
   −
If ''DOUT Control'' is disabled, scenario will only generate events without digital output activation. If ''DOUT Control'' is enabled DOUT1/DOUT2 (optional) turns ON if Ignition turns ON (Ignition Source is configured to 1). After iButton ID is read (any iButton is attached), DOUT1/DOUT2 turns OFF. After iButton identification, configured Ignition Source can be turned OFF (Ignition Source is configured to 0) for no longer than 30 seconds, otherwise immobilizer must be repeated. If ''iButton List Check'' parameter is enabled, authorization will be successful only if the attached iButton is specified in the iButton list.
+
If ''DOUT Control'' is disabled, scenario will only generate events without digital output activation. If ''DOUT Control'' is enabled {{{text_dout|DOUT1/DOUT2}}} (optional) turns ON if Ignition turns ON (Ignition Source is configured to 1). After iButton ID is read (any iButton is attached), {{{text_dout|DOUT1/DOUT2}}} turns OFF. After iButton identification, configured Ignition Source can be turned OFF (Ignition Source is configured to 0) for no longer than 30 seconds, otherwise immobilizer must be repeated. If ''iButton List Check'' parameter is enabled, authorization will be successful only if the attached iButton is specified in the iButton list.
 
<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/>
 
<br/><br/><br/><br/><br/><br/><br/><br/><br/><br/>
    
==iButton Read Notification==
 
==iButton Read Notification==
   −
[[Image:Fmb120_iButton_read.png|300px|right]]
+
{{{pic_ibutton_read|[[Image:Fmb120_iButton_read.png|300px|right]]}}}
    
This functionality allows user to see when iButton is read. Selected DOUT turns on for a configured duration, and after DOUT ON duration ends configured DOUT does not turn on even if iButton is left attached.
 