Line 1: |
Line 1: |
| == Overspeeding == | | == Overspeeding == |
| [[File:Overspeedinggif2.gif|alt=|right|374x374px]] | | [[File:Overspeedinggif2.gif|alt=|right|374x374px]] |
− | When vehicle speed exceeds the configured maximum speed value, the scenario is activated, and an event record is generated{{{text_dout| and digital output status is changed to 1 when configured}}}.<br />Detected speed has to be greater than configured max speed +3% of configured max speed for the overspeeding event to start. To stop overspeeding event detected speed has to be lower than the configured max speed -3% of the configured max speed. | + | When vehicle speed exceeds configured maximum speed value the scenario is activated, and an event record is generated{{{text_dout| and digital output status is changed to 1 when configured}}}.<br />Detected speed has to be greater than configured max speed +3% of configured max speed for the overspeeding event to start. To stop overspeeding event detected speed has to be lower than configured max speed -3% of configured max speed. |
| Configurable parameters: | | Configurable parameters: |
| | | |
| <br /> | | <br /> |
− | *Priority – defines the priority of overspeeding scenario: 0 – disabled, 1 – low, 2 – high. | + | *Priority – defines the priority of overspeeding scenario: 0 – disabled, 1 – low, 2 – high, 3 – panic. |
− | *Max speed – it is the maximum allowed speed that can be reached. If the speed exceeds the configured value, then the event will occur. | + | *Max speed – it is the maximum allowed speed that can be reached. If the speed exceeded configured value, then the event will occur. |
| | | |
| ==Trip== | | ==Trip== |
Line 18: |
Line 18: |
| *'''Disable''' - disable scenario. | | *'''Disable''' - disable scenario. |
| *'''Low Priority''' - when low priority event is triggered, device '''makes additional record''' with indication of event cause. | | *'''Low Priority''' - when low priority event is triggered, device '''makes additional record''' with indication of event cause. |
− | *'''High Priority''' - module makes additional record with High priority flag and '''sends event packet immediately''' to the server by '''GPRS'''. | + | *'''High Priority''' - module makes additional record with High priority flag and '''sends event packet immediately''' to the server by |
− | <br>
| + | '''GPRS'''. |
− | <br>
| |
| | | |
| ==Unplug detection== | | ==Unplug detection== |
− |
| |
| [[File:Unplug2.gif|alt=|right]] | | [[File:Unplug2.gif|alt=|right]] |
− |
| |
| An event will be generated when is unplugged from {{{txt_src|external power}}} or plugged back in again. | | An event will be generated when is unplugged from {{{txt_src|external power}}} or plugged back in again. |
| '''Priority''' | | '''Priority''' |
| *'''Disable''' - disable scenario. | | *'''Disable''' - disable scenario. |
| *'''Low Priority''' - when low priority event is triggered, device '''makes additional record''' with indication of event cause. | | *'''Low Priority''' - when low priority event is triggered, device '''makes additional record''' with indication of event cause. |
− | *'''High Priority''' - module makes additional record with High priority flag and '''sends event packet immediately''' to the server by '''GPRS'''. | + | *'''High Priority''' - module makes additional record with High priority flag and '''sends event packet immediately''' to the server by |
− | <br>
| + | '''GPRS'''. |
− | <br>
| + | *'''Unplug mode''' -The feature informs after the device is disconnected from the main power source. |
− | <br>
| |
− | <br>
| |
| | | |
| ==Static navigation== | | ==Static navigation== |
Line 43: |
Line 38: |
| | | |
| ==Digital output overcurrent recovery== | | ==Digital output overcurrent recovery== |
− | The feature will attempt to recover the DOUT state when overcurrent is detected in the circuit. DOUT will be toggled ON/OFF either until overcurrent is no longer detected or a maximum of 10 times. | + | The feature will attempt to recover DOUT state when overcurrent is detected in the circuit. DOUT will be toggled ON/OFF either until overcurrent is no longer detected or a maximum for 10 times.<br><br> |
− | [[File:Digital Output Overcurrent Recovery.png|thumb]]
| |
| | | |
| [[Category:FTC921 Configuration]] | | [[Category:FTC921 Configuration]] |