- Sort by - Here TAT100 device will send the newest records first when Newest is selected, which is useful in cases when the most important parameter set is the most recent one, as a result other records will be sent right after the newest records are received by AVL application.
- ACK Type - Possible to choose TCP/IP or AVL type
- First Power On record - first Power On record is a feature that when enabled sends first record on first manual power-up by switch. It can be turned on/off also by SMS/GPRS command.
More about First Power On record feature:
This parameter has an ID 199.
When enabled, the device on first power on will perform standard operations like in period record sending - time synchronization, getting GNSS fix, getting LBS data and etc. The time period of time from the moment of switching on the device and record sending strongly depends on configuration and time for fix searching. For example:
- When the tracking source is GNSS, in good conditions (clear sky, antenna pointing upwards) the first record will be sent approximately after 2 minutes from the time the device is turned on.
- If the location source is LBS only, the record can be received even more quickly - after about 90 seconds.
Depending on how bad the conditions are, the time to send a record can be significantly longer (a few additional minutes).
Note |
Some things that should be taken in consideration:
1. Static navigation logic will be ingored for this record.
2. When working with Recovery mode scenario, this first record will be an alarm record if Update frequency parameter is sufficiently short to generate an alarm before sending a record.